Hello everybody,
I have an Tektronix 2465A , Serial number B 033501. After power up the on screen display shows a ALL 00 PASS 017F. Presing A/B trigger leaves this screen and the 4 traces forthe 4 channels appear. I have a service manual. Well, I suspect a problem with the controller board, but I am not shure. Using an external xtal controlled TG501 or similar: Errorneous behaviour shows up when I use the cursor-guided time measurement: It works correct until 20 us/div. But for sweep speed 10 us/div and faster: Deviation ist more than 20%.. That means, even if I use a constant 10kHz or 20 kHz as an input, measurement is correct with the 20us/div setting. Using a 10us/Div setting and readjusting the cursors, it's approx. 20% wrong. Has anyone seen this before? Or a good point to start the repair procedure? Svc. Manual doesn't give me a good clue. This error message does not show up. Andreas |
#2
![]()
Posted to sci.electronics.repair
|
|||
|
|||
![]()
On Wed, 23 Sep 2009 05:15:48 -0700 (PDT) Andreas Tekman
wrote in Message id: : Hello everybody, I have an Tektronix 2465A , Serial number B 033501. After power up the on screen display shows a ALL 00 PASS 017F. Presing A/B trigger leaves this screen and the 4 traces forthe 4 channels appear. I have a service manual. Well, I suspect a problem with the controller board, but I am not shure. Using an external xtal controlled TG501 or similar: Errorneous behaviour shows up when I use the cursor-guided time measurement: It works correct until 20 us/div. But for sweep speed 10 us/div and faster: Deviation ist more than 20%.. That means, even if I use a constant 10kHz or 20 kHz as an input, measurement is correct with the 20us/div setting. Using a 10us/Div setting and readjusting the cursors, it's approx. 20% wrong. Has anyone seen this before? Or a good point to start the repair procedure? Svc. Manual doesn't give me a good clue. This error message does not show up. Andreas Hi Andreas, you might want to sign up and post your question he http://tech.groups.yahoo.com/group/TekScopes/ There's a *lot* of 24XX experts there. |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Tektronix 2465B startup error | Electronics Repair | |||
Tektronix 2465B error code interpretation | Electronics Repair | |||
tektronix 2465 error code | Electronics Repair | |||
Tektronix 2465A Channel 1 problem | Electronics Repair | |||
Tektronix SD-24 EEPROM error | Electronics Repair |