I have a Kenwood VR-407 which keeps going into protection. The ±12VDC
supplies are unbalanced. The schematic for the circuit is posted in a.b.s. It's just a basic circuit, it uses a center tapped transformer feeding into a full-wave bridge, with the center tap grounded, with a positive and negative three terminal 12 volt regulator. No rocket science here. However, the supplies are unbalanced, pretty severely. The input to the bridge is 14.24 & 14.15 VAC. The output of the bridge is -25.28 & 10.23VDC with .685 & .240VAC ripple, respectively. I pulled the board from the unit and powered up each regulator individually . With -18VDC in across the negative, there was .1A draw & -11.90VDC out. With +18V in across the positive regulator, there was .1A draw & 11.83VDC out, so the reguators are fine and neither has excessive current draw down the line. When I put an external supply across both bridge capacitors I saw the same unbalance. With 35VDC across the caps, there was 25.94 across the negative cap and 8.99V across the postitive cap. I connected a capacitor in parallel across both caps individually, but it didn't create any significant change. Is it probable that one of the caps is bad causing the unbalance? Thanks, and I'll provide any more information if necessary. |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Showers with unbalanced water supplies | UK diy | |||
DC supplies | Woodworking | |||
ERM supplies? | Metalworking | |||
Unbalanced Phase Converters and Power Loss | Metalworking | |||
FWW bandsaw review unbalanced? | Woodworking |