Electronics Repair (sci.electronics.repair) Discussion of repairing electronic equipment. Topics include requests for assistance, where to obtain servicing information and parts, techniques for diagnosis and repair, and annecdotes about success, failures and problems.

 
 
LinkBack Thread Tools Search this Thread Display Modes
Prev Previous Post   Next Post Next
  #1   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 4
Default Sony GDM-F500R (G1 Chassis) has trouble turning on

I got this monitor used five years ago. Since then it has always had
the overbrightness problem, but I scraped by with brightness set to 0
and contrast to 100. This was annonying, and the local service center
in India refused to service it. About a year back, it started
exhibiting a new problem -- it will not turn at all! The power LED
will turn on, but will flash in amber every 1.25 seconds. Turning it
on and off did nothing. So I put the monitor in cold storage. After
about a couple of months, curiosity got the better of me, and when I
plugged it in, it worked just fine. It worked for some more months,
and then mysteriously, refused to turn on one fine day. All I got is
that blinking amber light. In frustration/desperation, I pushed the
power button for about fifteen minutes, and it turned on. Everyday
since then, regardless of whether it was in standby mode or turned off
overnight, my daily morning ritual is to repeatedly push the power
button in order to turn my monitor on. Sometimes it takes a few
minutes, sometimes over couple of hours.
After some googling, I was able to download the schematic for it and
also got information on using WinDAS to adjust its G2 register to
correct the brightness problem. I build the necessary serial cable and
now the monitor is close to perfect (displaywise: G2 was set to 199, I
lowered it to 155), except for the power-on problem.

Here is some detailed information on how I get to turn my monitor on:
With 220V supply:
1. Turn the monitor on. If amber light flashes, go to #2, else it
turns on.
2. Turn it off. Wait for 5 sec (exact)
3. Repeat from 1.

With 110V Supply:
1. Turn the monitor on. If amber light flashes, go to #2, else it
turns on.
2. Turn it off. Wait for less than 1 sec.
3. Repeat from 1.

The interesting thing to note here is that when the monitor does
eventually turn on, it is preceded by the sounds of relay clicks. Once
the relays start clicking, it will not turn on right away, but after a
few more on-off cycles, it will. The moment I hear the first relay
click, I am relieved since I know the monitor will eventually turn on.
But I think the problem is getting worse, since my daily wait time is
getting longer.

I suspect some electrolytic capacitor has gone bad, but don't have an
ESR meter. I am going to build an ESR meter and go over all the
electrolytic capacitors inside.

Does anyone have better clue than me, or is it a well known problem?

Thanks.

 
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
32" Sony tv model:KV-32S22,chassis:SCC-K97D-A,chassis:AA-2D [email protected] Electronics Repair 2 February 8th 06 12:55 PM
Sony TV Trouble (kv27dx) Silvio Electronics Repair 1 November 7th 05 12:40 AM
Sound trouble on GE 27GT720 (Chassis CTC203AX1) -- Need help... Scott_SS Electronics Repair 2 October 16th 05 11:59 PM
TV Chassis gt8821 Trouble Seb Electronics Repair 3 April 6th 05 09:07 PM
Sony SPP-A941 Trouble Penny Electronics Repair 2 October 20th 03 05:10 PM


All times are GMT +1. The time now is 09:52 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us