27" RCA dead.
Model # 27R430T (YX1), Chassis # ITC008FAR, dead, nothing shorted, or
leaky, all standby voltages are ok, plug unit in, & just relay click for degaussing. No start up, or High Voltage. Could the tact switches be leaky? It has a front panel board with the IR sensor, & the tact switches on it. Dani. |
#2
Posted to sci.electronics.repair
|
|||
|
|||
27" RCA dead.
You will need to get a bit deeper into the device, checking the voltages at
the Eprom and MPU to determine if the Data or Clock lines are being loaded down. Will definately need a good schematic of the circuit to start tracing the associated lines to the other probable devices. "Dani" wrote in message ups.com... Model # 27R430T (YX1), Chassis # ITC008FAR, dead, nothing shorted, or leaky, all standby voltages are ok, plug unit in, & just relay click for degaussing. No start up, or High Voltage. Could the tact switches be leaky? It has a front panel board with the IR sensor, & the tact switches on it. Dani. |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
JVC 32 " T.V. dead. | Electronics Repair | |||
30" Phillips T.V. dead. | Electronics Repair | |||
Sony Portable Stereo CFD-E90 is "Dead" | Electronics Repair | |||
Dead power supply making "whining" sound | Electronics Repair | |||
Hitachi 35UX85B TV - Dead with periodic "Chirping" sound | Electronics Repair |