Default Panasonic TV model CT36SX12F blows fuse with degausing coils plugged in.

The 6.3 amp fuse was open. I replaced it with a 4.0 amp just for test
purposes. The degaussing coils happened to be unplugged at the time so
that I could get the chassis out for inspection and the set came on
fine. I then plugged the coils in and tried it. There was a loud hum
from the coils and the fuse lit up and opened. It seems that I recall a
certain series of set that had a problem with the degauss thermistors.
Can't remember if it was Panasonic or someone else's though. I haven't
got a 6.3 amp fuse but I'm pretty sure judging by the way the 4.0 amp
lit up the 6.3 would probably not last either. Is anyone familiar with
this problem who can possibly elaborate on it further? Thanks for any
help. Lenny Stein, Barlen Electronics.

  #3   Report Post  
Posted to sci.electronics.repair
kip kip is offline
external usenet poster
 
Posts: 103
Default Panasonic TV model CT36SX12F blows fuse with degausing coils plugged in.

Lenny ...Replace the Thermistor ( just in case ) and put in a SLOW BLOW
fuse.
That will fix it.
kip

wrote in message
ups.com...
The 6.3 amp fuse was open. I replaced it with a 4.0 amp just for test
purposes. The degaussing coils happened to be unplugged at the time so
that I could get the chassis out for inspection and the set came on
fine. I then plugged the coils in and tried it. There was a loud hum
from the coils and the fuse lit up and opened. It seems that I recall a
certain series of set that had a problem with the degauss thermistors.
Can't remember if it was Panasonic or someone else's though. I haven't
got a 6.3 amp fuse but I'm pretty sure judging by the way the 4.0 amp
lit up the 6.3 would probably not last either. Is anyone familiar with
this problem who can possibly elaborate on it further? Thanks for any
help. Lenny Stein, Barlen Electronics.



  #4   Report Post  
Posted to sci.electronics.repair
Art Art is offline
external usenet poster
 
Posts: 195
Default Panasonic TV model CT36SX12F blows fuse with degausing coils plugged in.

BTW Panasonic does have a bulletin regarding nuisance fuse blowing with
appropriate remedies.
"kip" wrote in message
.. .
Lenny ...Replace the Thermistor ( just in case ) and put in a SLOW BLOW
fuse.
That will fix it.
kip

wrote in message
ups.com...
The 6.3 amp fuse was open. I replaced it with a 4.0 amp just for test
purposes. The degaussing coils happened to be unplugged at the time so
that I could get the chassis out for inspection and the set came on
fine. I then plugged the coils in and tried it. There was a loud hum
from the coils and the fuse lit up and opened. It seems that I recall a
certain series of set that had a problem with the degauss thermistors.
Can't remember if it was Panasonic or someone else's though. I haven't
got a 6.3 amp fuse but I'm pretty sure judging by the way the 4.0 amp
lit up the 6.3 would probably not last either. Is anyone familiar with
this problem who can possibly elaborate on it further? Thanks for any
help. Lenny Stein, Barlen Electronics.





  #5   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 257
Default Panasonic TV model CT36SX12F blows fuse with degausing coils plugged in.

I replaced the thermistor with a new one. It checked out resistance
wise cold just like the old one so maybe the old one was good and the
original fuse just stressed. I put in a slow blow fuse and the set
seems to be OK. Thanks for the assistance. Lenny.
Art wrote:
BTW Panasonic does have a bulletin regarding nuisance fuse blowing with
appropriate remedies.
"kip" wrote in message
.. .
Lenny ...Replace the Thermistor ( just in case ) and put in a SLOW BLOW
fuse.
That will fix it.
kip

wrote in message
ups.com...
The 6.3 amp fuse was open. I replaced it with a 4.0 amp just for test
purposes. The degaussing coils happened to be unplugged at the time so
that I could get the chassis out for inspection and the set came on
fine. I then plugged the coils in and tried it. There was a loud hum
from the coils and the fuse lit up and opened. It seems that I recall a
certain series of set that had a problem with the degauss thermistors.
Can't remember if it was Panasonic or someone else's though. I haven't
got a 6.3 amp fuse but I'm pretty sure judging by the way the 4.0 amp
lit up the 6.3 would probably not last either. Is anyone familiar with
this problem who can possibly elaborate on it further? Thanks for any
help. Lenny Stein, Barlen Electronics.




Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Metal Working Machinery New and Used in Australia and for Export [email protected] Metalworking 0 February 23rd 05 02:54 AM
fuse blows RubbishRat Electronics Repair 1 July 25th 04 12:03 AM
GE (Panasonic ) VCR model 1VCR4002X old top loader wired remote questio Asimov Electronics Repair 0 March 29th 04 04:35 AM
Indesit dishwasher D3000WG? blows fuse John Stumbles UK diy 1 February 29th 04 11:35 AM
TV Remote Control rubber pad(UR50CT1071) used in remote control for Panasonic TV Model TX-29GF10X Steve Electronics Repair 4 November 1st 03 02:27 PM


All times are GMT +1. The time now is 08:40 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"