Home |
Search |
Today's Posts |
|
Electronics Repair (sci.electronics.repair) Discussion of repairing electronic equipment. Topics include requests for assistance, where to obtain servicing information and parts, techniques for diagnosis and repair, and annecdotes about success, failures and problems. |
Reply |
|
LinkBack | Thread Tools | Display Modes |
#1
Posted to sci.electronics.repair
|
|||
|
|||
PTK195 convergence power supply
I need the RCA part number to the updated convergence power supply. Thanks .
|
#2
Posted to sci.electronics.repair
|
|||
|
|||
PTK195 convergence power supply
NLA per posts from Thomson, have to repair down to the component level. May
want to call them or their parts department to confirm. "Mike Bates" wrote in message . .. I need the RCA part number to the updated convergence power supply. Thanks . |
#3
Posted to sci.electronics.repair
|
|||
|
|||
PTK195 convergence power supply
They are supposed to be interchangeable, number I got is: 239123
convergence board You can easily fix them, usually a diode, or the three legged regulator or the STK IC. Dani,. Mike Bates wrote: I need the RCA part number to the updated convergence power supply. Thanks . |
#4
Posted to sci.electronics.repair
|
|||
|
|||
PTK195 convergence power supply
the power supply works, it keeps shutting down.
I bypassed the opto, and it stays on, the STK gets hot, and the picture will start to pulsate from corrected, and uncorrected state. I replaced the diodes, checked all resistors. The convergence heatsinks feel normal. I pulled a cap next to the STK, had its plastic below the top, didnt know if it was bad or not. left it out for awhile, put it back in, and noticed the STK stayed cold, had corrected convergence. the red convergence heatsinks got hotter than a firecracker, so I powered down, and TOTALLY forgot that I left the cap out. Im an idiot. wrote in message oups.com... They are supposed to be interchangeable, number I got is: 239123 convergence board You can easily fix them, usually a diode, or the three legged regulator or the STK IC. Dani,. Mike Bates wrote: I need the RCA part number to the updated convergence power supply. Thanks . |
#5
Posted to sci.electronics.repair
|
|||
|
|||
PTK195 convergence power supply
that cap must have been for regulation, I lost the old one, but I think it
was 10uf at 63volt, someone confirm? "Mike Bates" wrote in message . .. the power supply works, it keeps shutting down. I bypassed the opto, and it stays on, the STK gets hot, and the picture will start to pulsate from corrected, and uncorrected state. I replaced the diodes, checked all resistors. The convergence heatsinks feel normal. I pulled a cap next to the STK, had its plastic below the top, didnt know if it was bad or not. left it out for awhile, put it back in, and noticed the STK stayed cold, had corrected convergence. the red convergence heatsinks got hotter than a firecracker, so I powered down, and TOTALLY forgot that I left the cap out. Im an idiot. wrote in message oups.com... They are supposed to be interchangeable, number I got is: 239123 convergence board You can easily fix them, usually a diode, or the three legged regulator or the STK IC. Dani,. Mike Bates wrote: I need the RCA part number to the updated convergence power supply. Thanks . |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Wanted: Someone to examine switchmode power supply... | Electronics Repair | |||
NEC MultiSync LCD1700M Power Supply Problem | Electronics Repair | |||
testing ATX power supply | Electronics Repair | |||
Sony KV-2782R Power supply, and KV-2785R same. | Electronics Repair | |||
Trying to find power supply for external CD burner | Electronics Repair |