Everything was working fine...then one day, TV stopped working. I
checked the circuit. Q404 was blown. Changed it. Turned the power ON, it blew again - stupid me. After checking for other shorts, took out all the CRT tube connections from ditstribution block. Changed Q404. Nothing blew. Put in red tube, no problem. Connected blue tube, no problem. Connected green tube, Q404 is shorted. Took out green tube, changed Q404. TV worked fine. Picture is messed up as green is missing but the video and audio otherwise is good. Checked green yokes (how do you check them?) by switching them with blue one (I always kept the green tube disconnected). No problems. So that means yokes are fine, right? May be the distribution block has a problem and can handle only two tubes at a time. Took out blue one and only connected red and green. Same problem - blew Q404. Gave the boards (only the signal board and the power board) to a friend. Who hooked them up at his shop and said everything is working fine. The only thing to do is to replace the green tube. Ordered one. Replaced it. Turned the power on and the Q404 got shorted! By now, my supplier is running out of Q404! And I am running out of ideas to test. So I seek help. Obviously, there is something about green tube - are you supposed to do something to the tube before you connect it? What can be the problem? How do I test for it? What am I doing wrong? Any help is appreciated. Thanks junglee |
#2
|
|||
|
|||
Shorted Green CRT.
"junglee" wrote in message ups.com... Everything was working fine...then one day, TV stopped working. I checked the circuit. Q404 was blown. Changed it. Turned the power ON, it blew again - stupid me. After checking for other shorts, took out all the CRT tube connections from ditstribution block. Changed Q404. Nothing blew. Put in red tube, no problem. Connected blue tube, no problem. Connected green tube, Q404 is shorted. Took out green tube, changed Q404. TV worked fine. Picture is messed up as green is missing but the video and audio otherwise is good. Checked green yokes (how do you check them?) by switching them with blue one (I always kept the green tube disconnected). No problems. So that means yokes are fine, right? May be the distribution block has a problem and can handle only two tubes at a time. Took out blue one and only connected red and green. Same problem - blew Q404. Gave the boards (only the signal board and the power board) to a friend. Who hooked them up at his shop and said everything is working fine. The only thing to do is to replace the green tube. Ordered one. Replaced it. Turned the power on and the Q404 got shorted! By now, my supplier is running out of Q404! And I am running out of ideas to test. So I seek help. Obviously, there is something about green tube - are you supposed to do something to the tube before you connect it? What can be the problem? How do I test for it? What am I doing wrong? Any help is appreciated. Thanks junglee |
#3
|
|||
|
|||
I agree with you that it looks like a shorted green CRT. But I just
bought a new CRT! Did I do something to short it? How can I test for this short? Thanks for your help. junglee |
#4
|
|||
|
|||
Sounds like the new tube did not get the new hv lead properly attached
and sealed to the tube and allowed to cure a minimum of 24 hours before applying HV. junglee wrote: I agree with you that it looks like a shorted green CRT. But I just bought a new CRT! Did I do something to short it? How can I test for this short? Thanks for your help. junglee |
#5
|
|||
|
|||
David,
You are correct as always! (I have been watching this news group and am really impressed with your insights!) I did not do what you just described. I did not allow 24 hours for curing. Now the main question I have is - did I ruin the CRT? I am going to seal the hv lead and allow it to cure for 24 hours. Is there anyway for me to test the CRT? Is it too late? Thanks. junglee wrote: Sounds like the new tube did not get the new hv lead properly attached and sealed to the tube and allowed to cure a minimum of 24 hours before applying HV. |
#6
|
|||
|
|||
Need to remove the anode lead, clean the connection thoroughly, looking for
any carbon tracing on the outside of the glass envelope. Re-attach the anode lead with sufficient sealant and let cure 24+ hours. If the carbon track has been removed and the seal done properly you should have an operational device. Actually the only way to check that is to subject it to the application of operational voltages and currents. "junglee" wrote in message oups.com... David, You are correct as always! (I have been watching this news group and am really impressed with your insights!) I did not do what you just described. I did not allow 24 hours for curing. Now the main question I have is - did I ruin the CRT? I am going to seal the hv lead and allow it to cure for 24 hours. Is there anyway for me to test the CRT? Is it too late? Thanks. junglee wrote: Sounds like the new tube did not get the new hv lead properly attached and sealed to the tube and allowed to cure a minimum of 24 hours before applying HV. |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Update: Toshiba TV CE27C15, ch TAC9345 Sound Balance Problem | Electronics Repair | |||
Toshiba TV CE27C15, ch TAC9345 Sound Balance Problem | Electronics Repair | |||
ICs for Sale - Specials, obsolete and Memory | Electronics Repair | |||
Toshiba vertical problem | Electronics Repair | |||
Toshiba laptop power problem | Electronics Repair |