Electronics Repair (sci.electronics.repair) Discussion of repairing electronic equipment. Topics include requests for assistance, where to obtain servicing information and parts, techniques for diagnosis and repair, and annecdotes about success, failures and problems.

Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Thomas Abell
 
Posts: n/a
Default Serial data device needed

I am searching for a circuit diagram for a device that I can build. I need
this device to divide serial data while amplifying the signal so that both
outputs are equal to the input.

I need this because I have a serial device that is providing a one-way data
flow into the serial port on my computer. I want to be able to split this
signal and put it into two ports. Simply running the data in parallel to
both com ports doesn't work because I believe that too much signal is being
lost.

Can anyone offer suggestions?

Thanks.


  #2   Report Post  
Bill Jeffrey
 
Posts: n/a
Default

Is the data at TTL levels? Is so, get a hex inverter IC (7404 seies,
IIRC). Put the input stream into one inverter, connect its output to
the inputs of two other inverters. The outputs of those inverters are
what you want. Since there are six inverters in the package, and you
just used three of them, you can buffer two data lines per package.

Bill
----------------------------

Thomas Abell wrote:

I am searching for a circuit diagram for a device that I can build. I need
this device to divide serial data while amplifying the signal so that both
outputs are equal to the input.

I need this because I have a serial device that is providing a one-way data
flow into the serial port on my computer. I want to be able to split this
signal and put it into two ports. Simply running the data in parallel to
both com ports doesn't work because I believe that too much signal is being
lost.

Can anyone offer suggestions?

Thanks.



  #3   Report Post  
Bill Jeffrey
 
Posts: n/a
Default

Sorry for the earlier post. The serial port is RS-232, which is not
directly TTL-compatible. Though there are several versions of RS-232, I
believe the common one uses +12VDC and -12VDC to represent the two logic
states. To buffer this, you will need a +/- 12VDC supply, and a couple
transistors and a couple resistors for each of the lines to be buffered.
Same principle as the inverter IC, but implemented with discrete
transistors.

Bill
----------------

Bill Jeffrey wrote:

Is the data at TTL levels? Is so, get a hex inverter IC (7404 seies,
IIRC). Put the input stream into one inverter, connect its output to
the inputs of two other inverters. The outputs of those inverters are
what you want. Since there are six inverters in the package, and you
just used three of them, you can buffer two data lines per package.

Bill
----------------------------

Thomas Abell wrote:

I am searching for a circuit diagram for a device that I can build. I
need this device to divide serial data while amplifying the signal so
that both outputs are equal to the input.

I need this because I have a serial device that is providing a one-way
data flow into the serial port on my computer. I want to be able to
split this signal and put it into two ports. Simply running the data
in parallel to both com ports doesn't work because I believe that too
much signal is being lost.

Can anyone offer suggestions?

Thanks.




  #4   Report Post  
Franc Zabkar
 
Posts: n/a
Default

On Thu, 7 Apr 2005 13:49:14 -0500, "Thomas Abell"
put finger to keyboard and composed:

I am searching for a circuit diagram for a device that I can build. I need
this device to divide serial data while amplifying the signal so that both
outputs are equal to the input.

I need this because I have a serial device that is providing a one-way data
flow into the serial port on my computer. I want to be able to split this
signal and put it into two ports. Simply running the data in parallel to
both com ports doesn't work because I believe that too much signal is being
lost.

Can anyone offer suggestions?

Thanks.


You *should* be able to drive two RS232 inputs from one output. If
not, then you could buffer the output with an MC1489 quad line
receiver and use this to drive an MC1488 quad line driver.
Alternatively, to avoid the need for additional +/-12V supplies, you
could use a single +5V Maxim IC with on-chip charge pumps.


- Franc Zabkar
--
Please remove one 's' from my address when replying by email.
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
repair: 4 Millions Domains data with Category [email protected] Home Repair 0 October 29th 04 03:25 PM
Anybody actually seen this new safety device? Mike G Woodworking 99 July 5th 04 02:41 PM
Semi OT Electrical Question John Moorhead Woodworking 41 April 9th 04 06:22 PM
I am looking for some silicon serial number devices. Bert Electronics 0 February 18th 04 08:18 AM
USB to serial or parallel Wouter van Ooijen Electronics 4 August 29th 03 08:03 PM


All times are GMT +1. The time now is 04:02 PM.