Old October 14th 07, 05:41 PM posted to uk.d-i-y
bof
external usenet poster
 
Posts: 188
Default Ideal Response 120 combi - flashing LED and no heating


On an Ideal Response 120 combi, does anyone know what a flashing
"Central Heating" LED (behind the cosmetic cover) means? The symptoms
are the boiler won't light if the CH is on though the pump pumps the CH
water OK and the DHW works.

MTIA


--
bof at bof dot me dot uk
Ads
  #2  
Old October 15th 07, 07:55 PM posted to uk.d-i-y
external usenet poster
 
Posts: 2,231
Default Ideal Response 120 combi - flashing LED and no heating

On Sun, 14 Oct 2007 16:41:32 +0100, bof wrote:

On an Ideal Response 120 combi, does anyone know what a flashing
"Central Heating" LED (behind the cosmetic cover) means? The symptoms
are the boiler won't light if the CH is on though the pump pumps the CH
water OK and the DHW works.


THE stock fault for this boiler is a leaking heat exchanger.
The usual presenting symptoms are that the boiler won't light because the
ignition is wet.




--
Ed Sirett - Property maintainer and registered gas fitter.
The FAQ for uk.diy is at http://www.diyfaq.org.uk
Gas fitting FAQ http://www.makewrite.demon.co.uk/GasFitting.html
Sealed CH FAQ http://www.makewrite.demon.co.uk/SealedCH.html
Choosing a Boiler FAQ http://www.makewrite.demon.co.uk/BoilerChoice.html
  #3  
Old October 15th 07, 08:15 PM posted to uk.d-i-y
bof
external usenet poster
 
Posts: 188
Default Ideal Response 120 combi - flashing LED and no heating

In message , Ed Sirett
writes
On Sun, 14 Oct 2007 16:41:32 +0100, bof wrote:

On an Ideal Response 120 combi, does anyone know what a flashing
"Central Heating" LED (behind the cosmetic cover) means? The symptoms
are the boiler won't light if the CH is on though the pump pumps the CH
water OK and the DHW works.


THE stock fault for this boiler is a leaking heat exchanger.
The usual presenting symptoms are that the boiler won't light because the
ignition is wet.


Thanks for the reply. The boiler lights OK when it's DHW, and the CH
doesn't get hot even when the DHW is running. I'm sure the pump's OK as
when I switch off the DHW there's a couple of seconds surge of hot in
the CH.





--
bof at bof dot me dot uk
  #4  
Old October 16th 07, 08:00 PM posted to uk.d-i-y
external usenet poster
 
Posts: 2,231
Default Ideal Response 120 combi - flashing LED and no heating

On Mon, 15 Oct 2007 19:15:27 +0100, bof wrote:

In message , Ed Sirett
writes
On Sun, 14 Oct 2007 16:41:32 +0100, bof wrote:

On an Ideal Response 120 combi, does anyone know what a flashing
"Central Heating" LED (behind the cosmetic cover) means? The symptoms
are the boiler won't light if the CH is on though the pump pumps the CH
water OK and the DHW works.


THE stock fault for this boiler is a leaking heat exchanger.
The usual presenting symptoms are that the boiler won't light because the
ignition is wet.


Thanks for the reply. The boiler lights OK when it's DHW, and the CH
doesn't get hot even when the DHW is running. I'm sure the pump's OK as
when I switch off the DHW there's a couple of seconds surge of hot in
the CH.

Firstly I'm sorry if I put you on the wrong trail here. You may well have
a model that has not yet eaten its heat exchanger (yet).

I don't have a manual for this model - what does it say?


--

Ed Sirett - Property maintainer and registered gas fitter.
The FAQ for uk.diy is at http://www.diyfaq.org.uk
Gas fitting FAQ http://www.makewrite.demon.co.uk/GasFitting.html
Sealed CH FAQ http://www.makewrite.demon.co.uk/SealedCH.html
Choosing a Boiler FAQ http://www.makewrite.demon.co.uk/BoilerChoice.html
  #5  
Old October 16th 07, 08:24 PM posted to uk.d-i-y
external usenet poster
 
Posts: 4,046
Default Ideal Response 120 combi - flashing LED and no heating


"Ed Sirett" wrote in message
...
On Mon, 15 Oct 2007 19:15:27 +0100, bof wrote:

In message , Ed Sirett
writes
On Sun, 14 Oct 2007 16:41:32 +0100, bof wrote:

On an Ideal Response 120 combi, does anyone know what a flashing
"Central Heating" LED (behind the cosmetic cover) means? The symptoms
are the boiler won't light if the CH is on though the pump pumps the CH
water OK and the DHW works.


THE stock fault for this boiler is a leaking heat exchanger.
The usual presenting symptoms are that the boiler won't light because the
ignition is wet.


Thanks for the reply. The boiler lights OK when it's DHW, and the CH
doesn't get hot even when the DHW is running. I'm sure the pump's OK as
when I switch off the DHW there's a couple of seconds surge of hot in
the CH.

Firstly I'm sorry if I put you on the wrong trail here. You may well have
a model that has not yet eaten its heat exchanger (yet).

I don't have a manual for this model - what does it say?


Check the pressure vessel charge. This goes flat quickly on these models.
Check the system pressure. It has a low pressure switch, so if pressure low
problems. I'm not sure if it also has a CH flow switch, if so check this.

  #6  
Old October 17th 07, 09:35 AM posted to uk.d-i-y
bof
external usenet poster
 
Posts: 188
Default Ideal Response 120 combi - flashing LED and no heating

In message , Ed Sirett
writes

I don't have a manual for this model - what does it say?


I don't know, I haven't got a manual either.



--
bof at bof dot me dot uk
  #7  
Old October 17th 07, 09:39 AM posted to uk.d-i-y
bof
external usenet poster
 
Posts: 188
Default Ideal Response 120 combi - flashing LED and no heating

In message ews.net,
Doctor Drivel writes

Check the pressure vessel charge. This goes flat quickly on these
models. Check the system pressure. It has a low pressure switch, so if
pressure low problems.


If the pressure's stable and, from prior experience, if the pressure
does drop it won't light the DHW either.


I'm not sure if it also has a CH flow switch, if so check this.


Thanks, the CH light flashes continuously, irrespective of whether the
CH/DHW/stat switch etc. are on or off, which seems to imply that there's
an internal fault of some kind before attempting to run the CH.



--
bof at bof dot me dot uk
  #8  
Old October 17th 07, 08:26 PM posted to uk.d-i-y
external usenet poster
 
Posts: 2,231
Default Ideal Response 120 combi - flashing LED and no heating

On Wed, 17 Oct 2007 08:39:45 +0100, bof wrote:

In message ews.net,
Doctor Drivel writes

Check the pressure vessel charge. This goes flat quickly on these
models. Check the system pressure. It has a low pressure switch, so if
pressure low problems.


If the pressure's stable and, from prior experience, if the pressure
does drop it won't light the DHW either.


I'm not sure if it also has a CH flow switch, if so check this.


Thanks, the CH light flashes continuously, irrespective of whether the
CH/DHW/stat switch etc. are on or off, which seems to imply that there's
an internal fault of some kind before attempting to run the CH.


There's a reset swtich somewhere IIRC.


--
Ed Sirett - Property maintainer and registered gas fitter.
The FAQ for uk.diy is at http://www.diyfaq.org.uk
Gas fitting FAQ http://www.makewrite.demon.co.uk/GasFitting.html
Sealed CH FAQ http://www.makewrite.demon.co.uk/SealedCH.html
Choosing a Boiler FAQ http://www.makewrite.demon.co.uk/BoilerChoice.html
  #9  
Old October 17th 07, 09:00 PM posted to uk.d-i-y
bof
external usenet poster
 
Posts: 188
Default Ideal Response 120 combi - flashing LED and no heating

In message , Ed Sirett
writes
On Wed, 17 Oct 2007 08:39:45 +0100, bof wrote:

In message ews.net,
Doctor Drivel writes

Check the pressure vessel charge. This goes flat quickly on these
models. Check the system pressure. It has a low pressure switch, so if
pressure low problems.


If the pressure's stable and, from prior experience, if the pressure
does drop it won't light the DHW either.


I'm not sure if it also has a CH flow switch, if so check this.


Thanks, the CH light flashes continuously, irrespective of whether the
CH/DHW/stat switch etc. are on or off, which seems to imply that there's
an internal fault of some kind before attempting to run the CH.


There's a reset swtich somewhere IIRC.


First thanks for all the suggestions. The cutout switch I know of is on
the bottom right, but if that pops out it shuts off the DHW and the CH.
This fault is something specific to the CH.

--
bof at bof dot me dot uk
 




Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On

Similar Threads
Thread Thread Starter Forum Replies Last Post
Ideal Response 80 Combi boiler's gas valve keeps sticking Neil Jowsey UK diy 1 October 9th 06 08:36 PM
ideal response 100 combi boiler stopped igniting dave griffiths UK diy 1 September 22nd 06 11:32 PM
Ideal response 100 heat exchanger John UK diy 13 February 28th 06 10:16 PM
Ideal Response 120 leak Peter Andrews UK diy 0 October 22nd 05 07:05 PM
Ideal Response 100 Combi problem Pete Dowling UK diy 0 October 29th 03 10:15 AM


All times are GMT +1. The time now is 09:46 AM.


Powered by vBulletin® Version 3.6.4
Copyright ©2000 - 2014, Jelsoft Enterprises Ltd.SEO by vBSEO ©2010, Crawlability, Inc.
Copyright 2004-2014 DIYbanter.
The comments are property of their posters.