View Single Post
  #2   Report Post  
Posted to uk.d-i-y
Ed Sirett Ed Sirett is offline
external usenet poster
 
Posts: 2,231
Default Ideal Response 120 combi - flashing LED and no heating

On Sun, 14 Oct 2007 16:41:32 +0100, bof wrote:

On an Ideal Response 120 combi, does anyone know what a flashing
"Central Heating" LED (behind the cosmetic cover) means? The symptoms
are the boiler won't light if the CH is on though the pump pumps the CH
water OK and the DHW works.


THE stock fault for this boiler is a leaking heat exchanger.
The usual presenting symptoms are that the boiler won't light because the
ignition is wet.




--
Ed Sirett - Property maintainer and registered gas fitter.
The FAQ for uk.diy is at http://www.diyfaq.org.uk
Gas fitting FAQ http://www.makewrite.demon.co.uk/GasFitting.html
Sealed CH FAQ http://www.makewrite.demon.co.uk/SealedCH.html
Choosing a Boiler FAQ http://www.makewrite.demon.co.uk/BoilerChoice.html