Two questions about electrical and building codes:

(1) Can you mount two electrical boxes back-to-back? In this example,
I have a 2x4 stud wall, and right next to a doorway there have to be
lightswitches on either side of the wall. Due to space constraints,
I'll need to put the two boxes in the same location, on either side of
the wall. Using metal boxes, two regular-size boxes fit snugly into a
2x4 wall cavity (their backs nearly touch, and the grounding screws on
the back of one touches the other). All other options are quite
distasteful: Move one set of light switches up or down by 6", or move
them about 2' away from the doorway.

(2) Is there a limit to the maximum number of electrical boxes that
can be in a wall? In this case, we have a 32" wide wall stub that has
to contain a total of four electrical boxes (110V outlet, 240V outlet,
TV/network outlet, and light switches).

In either case, we are talking about standard wooden 2x4 construction
with 1/2" drywall. The walls do not need to be fire-rated. No studs
need to be but for these boxes, and all boxes are metal boxes (I don't
like plastic boxes).

If it matters: We are talking about the 1997 UBC and the 1999 NEC
here; I have read through all of the NEC, and found no mention of
either question. I don't have a copy of the UBC handy, but a web
search found no discussion of either topic.

Discussion and enlightenment would be appreciated.

--
The address in the header is invalid for obvious reasons. Please
reconstruct the address from the information below (look for _).
Ralph Becker-Szendy _firstname_@lr _dot_ los-gatos _dot_ ca.us
  #2   Report Post  
Rich Greenberg
 
Posts: n/a
Default Building code: Electrical boxes back-to-back, how many

In article 1079376715.616107@smirk,
wrote:
Two questions about electrical and building codes:

(1) Can you mount two electrical boxes back-to-back? In this example,
I have a 2x4 stud wall, and right next to a doorway there have to be


I don't know if the code permits this, but I have seen it done many
times.

(2) Is there a limit to the maximum number of electrical boxes that
can be in a wall? In this case, we have a 32" wide wall stub that has


No idea. My guess would be probably not a problem.

--
Rich Greenberg Work: Rich.Greenberg atsign worldspan.com + 1 770 563 6656
N6LRT Marietta, GA, USA Play: richgr atsign panix.com + 1 770 321 6507
Eastern time zone. I speak for myself & my dogs only. VM'er since CP-67
Canines:Val(Chinook,CGC,TT), Red & Shasta(Husky,(RIP)) Owner:Chinook-L
Atlanta Siberian Husky Rescue. www.panix.com/~richgr/ Asst Owner:Sibernet-L
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Thermostat Wiring Electrical Code Handi Home Repair 12 January 29th 04 02:30 PM
Electrical service ok or out of code Robert J Rolleston Home Repair 14 December 18th 03 04:19 AM
Forthcoming Building Regulations on electrical work (Part P) Andrew McKay UK diy 42 July 30th 03 08:05 AM


All times are GMT +1. The time now is 07:02 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"