Woodworking (rec.woodworking) Discussion forum covering all aspects of working with wood. All levels of expertise are encouraged to particiapte.

Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Posted to rec.woodworking
external usenet poster
 
Posts: 328
Default Gas line to the shop

I'm trying to get the finishing touches on the shop, and it's starting to
get cold here in Chicago. When the shop was in the building process, I
inquired with one of the city building inspectors about the proper way of
running a line for natural gas. He oh-so-subtlely suggested that I wait
until they were gone, and put it in after the fact. So, before the ground
gets frozen, I need to get this puppy in. I need to go about 50' to get
into the shop, then about another 35' to where the heater is. I'm wondering
what is typical as far as the gas line goes. From what I read, it seems
that some use polyethylene tubing, and others use regular black pipe. I've
even read about special galvanized "gas pipe". Any thoughts or suggestions?

todd


  #2   Report Post  
Posted to rec.woodworking
external usenet poster
 
Posts: 1,617
Default Gas line to the shop


"todd" wrote in message
...
I'm trying to get the finishing touches on the shop, and it's starting to
get cold here in Chicago. When the shop was in the building process, I
inquired with one of the city building inspectors about the proper way of
running a line for natural gas. He oh-so-subtlely suggested that I wait
until they were gone, and put it in after the fact. So, before the ground
gets frozen, I need to get this puppy in. I need to go about 50' to get
into the shop, then about another 35' to where the heater is. I'm
wondering what is typical as far as the gas line goes. From what I read,
it seems that some use polyethylene tubing, and others use regular black
pipe. I've even read about special galvanized "gas pipe". Any thoughts
or suggestions?

Call your utility and ask them what their requirements are. Some will allow
galvanized or copper; others won't.
Polyethylene?! Well, it won't rust.


  #3   Report Post  
Posted to rec.woodworking
external usenet poster
 
Posts: 328
Default Gas line to the shop


"Toller" wrote in message
...

"todd" wrote in message
...
I'm trying to get the finishing touches on the shop, and it's starting to
get cold here in Chicago. When the shop was in the building process, I
inquired with one of the city building inspectors about the proper way of
running a line for natural gas. He oh-so-subtlely suggested that I wait
until they were gone, and put it in after the fact. So, before the
ground gets frozen, I need to get this puppy in. I need to go about 50'
to get into the shop, then about another 35' to where the heater is. I'm
wondering what is typical as far as the gas line goes. From what I read,
it seems that some use polyethylene tubing, and others use regular black
pipe. I've even read about special galvanized "gas pipe". Any thoughts
or suggestions?

Call your utility and ask them what their requirements are. Some will
allow galvanized or copper; others won't.
Polyethylene?! Well, it won't rust.


I'll see what I can find out from the gas utility. BTW, polyethylene pipe
is (as I understand it) used in 90% of the natural gas distributions systems
in North America.

todd


  #4   Report Post  
Posted to rec.woodworking
external usenet poster
 
Posts: 2,047
Default Gas line to the shop


"todd" wrote:

I'm wondering
what is typical as far as the gas line goes.


Old way was to black iron from the street valve to the regulator at
the house, then black iron for the inside distribution.

When the iron developed leaks, a plumbing contractor pulls the orange
plastic line inside the black iron and you are good for life.

I had to have this done once and it was not that expensive considering
it was done on an emergency basis.

Today, I'd talk to a plumber first, especially considering the permit
headaches.

Don't want to get a permit?

Have a fire and the first thing insurance company is going to check is
that everything was according to permits.

Lew


  #5   Report Post  
Posted to rec.woodworking
external usenet poster
 
Posts: 1,617
Default Gas line to the shop


"todd" wrote in message
...

"Toller" wrote in message
...

"todd" wrote in message
...
I'm trying to get the finishing touches on the shop, and it's starting
to get cold here in Chicago. When the shop was in the building process,
I inquired with one of the city building inspectors about the proper way
of running a line for natural gas. He oh-so-subtlely suggested that I
wait until they were gone, and put it in after the fact. So, before the
ground gets frozen, I need to get this puppy in. I need to go about 50'
to get into the shop, then about another 35' to where the heater is.
I'm wondering what is typical as far as the gas line goes. From what I
read, it seems that some use polyethylene tubing, and others use regular
black pipe. I've even read about special galvanized "gas pipe". Any
thoughts or suggestions?

Call your utility and ask them what their requirements are. Some will
allow galvanized or copper; others won't.
Polyethylene?! Well, it won't rust.


I'll see what I can find out from the gas utility. BTW, polyethylene pipe
is (as I understand it) used in 90% of the natural gas distributions
systems in North America.

I learn something new everyday! Local utility says it is used on all mains
and services.
Last time I looked into it, maybe 10 years ago, it didn't even come up.




  #6   Report Post  
Posted to rec.woodworking
external usenet poster
 
Posts: 1,617
Default Gas line to the shop


"Lew Hodgett" wrote in message
...

"todd" wrote:

I'm wondering
what is typical as far as the gas line goes.


Old way was to black iron from the street valve to the regulator at
the house, then black iron for the inside distribution.

When the iron developed leaks, a plumbing contractor pulls the orange
plastic line inside the black iron and you are good for life.


A current "crisis" is people installing NG generators and finding their
pipes aren't big enough to supply everything. I would think there would be
a similar problem with filling the pipe with a PE liner. No?


  #7   Report Post  
Posted to rec.woodworking
external usenet poster
 
Posts: 2,047
Default Gas line to the shop


"Toller" wrote:

I would think there would be
a similar problem with filling the pipe with a PE liner. No?


Probably depends on pressure of the NG, but shouldn't be a problem.

As far as I know, one size fits all when it comes to orange gas line
for a user feed line.

Lew




  #8   Report Post  
Posted to rec.woodworking
external usenet poster
 
Posts: 200
Default Gas line to the shop


"todd" wrote in message
...
I'm trying to get the finishing touches on the shop, and it's starting to
get cold here in Chicago. When the shop was in the building process, I
inquired with one of the city building inspectors about the proper way of
running a line for natural gas. He oh-so-subtlely suggested that I wait
until they were gone, and put it in after the fact. So, before the ground
gets frozen, I need to get this puppy in. I need to go about 50' to get
into the shop, then about another 35' to where the heater is. I'm
wondering what is typical as far as the gas line goes. From what I read,
it seems that some use polyethylene tubing, and others use regular black
pipe. I've even read about special galvanized "gas pipe". Any thoughts
or suggestions?

todd


I work for a HVAC company and ALL we put in the ground is poly. As far as I
am concerned there is no other option! Black and galvanized pipe, no mater
how well it is covered and protected will fail eventually, sometimes fairly
soon. I replaced an underground gas line that was done in coated black pipe
that was underground for about 10 years. It failed at a fitting because the
protective tape and sealant did not hold up. Plus any where there was a nick
in the coating it was rusting badly and was due to fail. The house I live in
has black pipe going to the garage and I am getting ready to rip it out
before it fails!

I would look for a company that installs poly underground gas, dig the
trench yourself, and have them install the pipe. The worst part is digging
the trench! It would take less than one hour for them to lay the pipe and
risers.
Greg

  #9   Report Post  
Posted to rec.woodworking
Jon Jon is offline
external usenet poster
 
Posts: 37
Default Gas line to the shop

Todd,

I live just outside of Madison, WI. My shop is 100' away, actually an old
converted barn. They ran poly line the entire route, they placed it 48"
below the grade.

Jon


"todd" wrote in message
...
I'm trying to get the finishing touches on the shop, and it's starting to
get cold here in Chicago. When the shop was in the building process, I
inquired with one of the city building inspectors about the proper way of
running a line for natural gas. He oh-so-subtlely suggested that I wait
until they were gone, and put it in after the fact. So, before the ground
gets frozen, I need to get this puppy in. I need to go about 50' to get
into the shop, then about another 35' to where the heater is. I'm
wondering what is typical as far as the gas line goes. From what I read,
it seems that some use polyethylene tubing, and others use regular black
pipe. I've even read about special galvanized "gas pipe". Any thoughts
or suggestions?

todd



  #10   Report Post  
Posted to rec.woodworking
external usenet poster
 
Posts: 12
Default Gas line to the shop

I would think there would be
a similar problem with filling the pipe with a PE liner. No?


Probably depends on pressure of the NG, but shouldn't be a problem.


Normal for most places is 0.25 PSI - just a quarter of a PSI. At that low
of pressure, you need a decent size of pipe in order to supply large
volumes. Depending on the length of run, you need 3/4" pipe somewhere
between a 2.5KW and a 7.5KW generator, and by the time you're at a 12KW
generator, it doesn't take a terribly long run before you're looking at a
1.25" line.

Take a look at the NG supplies outside some restaurants. They're often
quite substantial.

steve




  #11   Report Post  
Posted to rec.woodworking
external usenet poster
 
Posts: 2,047
Default Gas line to the shop


"Steve Wolfe" wrote:

Normal for most places is 0.25 PSI - just a quarter of a PSI.


My info is definitely dated, but when I lived in Cleveland, East Ohio Gas
had a low pressure system (about 12"-15" of water column) and Columbia gas
used a higher pressure distribution (about 15PSIG) along with a pressure
regulator at the service entrance point of the building.

Assume not much has changed since I left.

Lew


  #12   Report Post  
Posted to rec.woodworking
external usenet poster
 
Posts: 200
Default Gas line to the shop



"Lew Hodgett" wrote in message
...

"Steve Wolfe" wrote:

Normal for most places is 0.25 PSI - just a quarter of a PSI.


My info is definitely dated, but when I lived in Cleveland, East Ohio Gas
had a low pressure system (about 12"-15" of water column) and Columbia gas
used a higher pressure distribution (about 15PSIG) along with a pressure
regulator at the service entrance point of the building.

Assume not much has changed since I left.

Lew



Around here it is getting pretty standard to run 2 PSI gas pressure into the
home, and regulate it down at each appliance. The installers get by running
everything in 1/2" stainless steel flex tubing that way. It also helps on
those long runs out to the shop. We bury 1" poly and at 2 PSI.....well, it
will run about anything a normal person can find to hook up to the gas line!
Greg

  #13   Report Post  
Posted to rec.woodworking
external usenet poster
 
Posts: 71
Default Gas line to the shop

Steve Wolfe wrote:
I would think there would be
a similar problem with filling the pipe with a PE liner. No?

Probably depends on pressure of the NG, but shouldn't be a problem.


Normal for most places is 0.25 PSI - just a quarter of a PSI. At that low
of pressure, you need a decent size of pipe in order to supply large
volumes. Depending on the length of run, you need 3/4" pipe somewhere
between a 2.5KW and a 7.5KW generator, and by the time you're at a 12KW
generator, it doesn't take a terribly long run before you're looking at a
1.25" line.

Take a look at the NG supplies outside some restaurants. They're often
quite substantial.

steve


Here the supplies run at 100+psi to local sub's, then down to 15psi and
final reg on arrival at the premises to inches of water level, even the
higher pressure mains (6" and below + possibly larger) are being
replaced in poly.
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Drain in the shop when the line runs up-hill? arw01 Woodworking 7 August 28th 06 06:52 PM
In-line vs. off-line chemical feeders Alan Home Repair 1 July 28th 05 02:33 AM
"Grass Gator n'Cut Fixed 4 Line Head" Weed Wacker Replacement For Bump-Line Feed Head ? Robert11 Home Repair 3 July 4th 05 02:49 PM
looking for info on "shop fox" line of machine tools F. George McDuffee Metalworking 7 March 22nd 05 10:38 PM


All times are GMT +1. The time now is 03:10 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"