Woodworking (rec.woodworking) Discussion forum covering all aspects of working with wood. All levels of expertise are encouraged to particiapte.

Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Posted to rec.woodworking
anthony
 
Posts: n/a
Default advice needed on homemade air filtration unit

Hi all, I need help/advice...

I just got an old furnace blower assembly with a 990 rpm 240 v motor. I
want to build an air filter unit.

The squirrel cage is 12" X 12" and I just hooked up a 1745rpm 115v motor.
The original motor was rated at 990rpm. Is the new motor going to give me
better result by spinning the squirrel cage virtually 2X faster? I was
wondering if I could get away with a unit having filters on three sides?

Is there any sites on the web that show IN Depth, CLOSE UP photos on how to
construct a unit?

thanks for any suggestions/help

Anthony


  #2   Report Post  
Posted to rec.woodworking
Dan Kratville
 
Posts: n/a
Default advice needed on homemade air filtration unit

anthony wrote:
Hi all, I need help/advice...

I just got an old furnace blower assembly with a 990 rpm 240 v motor. I
want to build an air filter unit.

The squirrel cage is 12" X 12" and I just hooked up a 1745rpm 115v motor.
The original motor was rated at 990rpm. Is the new motor going to give me
better result by spinning the squirrel cage virtually 2X faster? I was
wondering if I could get away with a unit having filters on three sides?

Is there any sites on the web that show IN Depth, CLOSE UP photos on how to
construct a unit?

thanks for any suggestions/help

Anthony


This isn't very closeup or in depth but I was planning on trying to
build this unit with a a squirrel cage blower myself.
Dan

http://wood.bigelowsite.com/air_filter/
  #3   Report Post  
Posted to rec.woodworking
Greg O
 
Posts: n/a
Default advice needed on homemade air filtration unit

"anthony" wrote in message
...
Hi all, I need help/advice...

I just got an old furnace blower assembly with a 990 rpm 240 v motor. I
want to build an air filter unit.

The squirrel cage is 12" X 12" and I just hooked up a 1745rpm 115v motor.
The original motor was rated at 990rpm. Is the new motor going to give me
better result by spinning the squirrel cage virtually 2X faster? I was
wondering if I could get away with a unit having filters on three sides?

Is there any sites on the web that show IN Depth, CLOSE UP photos on how
to construct a unit?

thanks for any suggestions/help

Anthony

What is the HP of the 115 volt motor? Twice the RPM will require
approximately 4 times the HP!!
I don't think its gonna work!


--
PoorUB
'05 Ultra Classic


  #4   Report Post  
Posted to rec.woodworking
anthony
 
Posts: n/a
Default advice needed on homemade air filtration unit

it's a 1/3 HP motor... I plugged it in, and it runs real smooth, but when
I put a paper towel close to the sides, well, let's just say that I wasn't
too impressed with the drawing power of the fan...

if any one can help, it's you guys/gals on this board!


"Greg O" wrote in message
...
"anthony" wrote in message
...
Hi all, I need help/advice...

I just got an old furnace blower assembly with a 990 rpm 240 v motor. I
want to build an air filter unit.

The squirrel cage is 12" X 12" and I just hooked up a 1745rpm 115v motor.
The original motor was rated at 990rpm. Is the new motor going to give
me better result by spinning the squirrel cage virtually 2X faster? I
was wondering if I could get away with a unit having filters on three
sides?

Is there any sites on the web that show IN Depth, CLOSE UP photos on how
to construct a unit?

thanks for any suggestions/help

Anthony

What is the HP of the 115 volt motor? Twice the RPM will require
approximately 4 times the HP!!
I don't think its gonna work!


--
PoorUB
'05 Ultra Classic



  #5   Report Post  
Posted to rec.woodworking
anthony
 
Posts: n/a
Default advice needed on homemade air filtration unit

thanks Dan!

"Dan Kratville" wrote in message
...
anthony wrote:
Hi all, I need help/advice...

I just got an old furnace blower assembly with a 990 rpm 240 v motor. I
want to build an air filter unit.

The squirrel cage is 12" X 12" and I just hooked up a 1745rpm 115v motor.
The original motor was rated at 990rpm. Is the new motor going to give
me better result by spinning the squirrel cage virtually 2X faster? I
was wondering if I could get away with a unit having filters on three
sides?

Is there any sites on the web that show IN Depth, CLOSE UP photos on how
to construct a unit?

thanks for any suggestions/help

Anthony

This isn't very closeup or in depth but I was planning on trying to build
this unit with a a squirrel cage blower myself.
Dan

http://wood.bigelowsite.com/air_filter/





  #6   Report Post  
Posted to rec.woodworking
 
Posts: n/a
Default advice needed on homemade air filtration unit

We did the following for brazing fumes but much of the expertise these
companies supply will be applicable to your use. I don't have any
connection with any of these and, when we did this, the information was
free.

Tom

Air Filtering Equipment

Equipment Choices
You can start as I did with a simple fan and a metal stovepipe. This
is very easy and cheap to install. The drawback is that it usually
sucks a lot of warm air out during cold weather.

Consultants
Most states provide free consulting. If you are in British Columbia
then you can contact the Workers' Compensation Board at (604)
276-3209.

Three Excellent Articles

1. One is by John Ashe of AAF (American Air Filter) International in
Louisville, KY. (305) 443-9353. His article is Controlling Welding
Fumes in the July, 1997 issue of The Fabricator. Reprints of the
article are available by calling (800) 477-1214 and asking for reprint
# APC-4-905.

2. Another good article was in the December 1996 issue of the same
magazine. It was written by Joe Topmiller who is Director of Technical
support for United Air Specialists at (800) 551-5401 in Cincinnati,
Ohio. The article is Addressing Air Quality Issues in the Workplace.

3. The third article is on new respiratory standards by Jay G. Mears in
Modern Woodworking. (248) 244-6439. It was called: Intelligence
Report: Getting Ready for 42 CFR part 84 call MSA and is available at
(888) 867-0602.

Equipment Suppliers:

1. AAF International (American Air Filters) -(305) 443-9353 -
small line but appropriate for most shop applications - great
technical support - (see articles section above). Excellent
technical advice.

2. Abicor Binzel (301) 846-4196 Frederick, MD - They only supply fume
extraction guns for welding. Great product if you need it.

3. Airflow Systems (214) 503-8008 Dallas, TX - wide variety of
units, overhead units, downdraft tables, and portable units - "Dust
and fume Exhaust" pamphlet has good technical information.
Recommended for literature.

4. Coppus (508) 756-8391 Millbury, MA - unique, portable dust
collection systems - also employee coolers for hot areas. Unique
products.

5. Dust Vent, Inc. (630) 543-9007 Addison, IL. - Wide range of
equipment and good literature. Recommended for literature.

6. Eurovac (905) 850-9828 in Ontario. -Central vacuum cleaner
systems and other dust collection equipment.

7. Farr Pollution Control Products (800) 479-6801 Los Angeles, CA. -
Overhead cleaning with or without arms.

8. Gardner Environmental Products (414) 485-4303 Horicon, WI
-Ceiling mounted and portable units.

9. Industrial Ventilation Group (800) 610-6010 Harbor Springs, MI
-Central and portable units, downdraft tables. Recommended for
literature.

10. Lincoln Electric (216) 481-8100 -Offers a central collection
system and portable units -just one mention in their catalog.

11. MAC Equipment, Inc. (800) 821-2476 - Huge, complete catalog.
Excellent information, great source to build your own system.
Recommended for literature.

12. Nederman (313) 729-3344 Westland, MI -Nice literature -looks
like nice overhead arm extraction equipment -good information on Do
It Yourself. Recommended for literature.

13. Plymovent (732) 417-0808 New Jersey -good equipment -great
free booklet "My Pocketguide to Clean Fresh Air". Recommended for
literature.

14. Sly, Inc. (216) 891-3200 Cleveland, OH -Shop size central
collection systems to huge industrial systems. Recommended for
literature.

15. Trion (800) 421-3956 Greensboro, NC -Overhead units -they
advertise a free clean air guide.

16. United Air Specialists (800) 551-5401 Cincinnati, Ohio -Invented
the original smoke eaters for bars, etc. -Good equipment -good
literature and great technical help. Recommended for literature.

Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Advice needed re fireplace and room heater shaz UK diy 3 December 30th 04 06:34 PM
Your advice on new a/c unit, please Dee Home Repair 21 December 8th 04 11:47 PM
Marantz 2330B Amp Schematic/Troubleshooting Advice Needed Marc Electronics Repair 0 October 27th 04 02:37 PM
Central Heating control unit replacement - advice please Damian Home Repair 1 December 29th 03 01:35 AM
Air Conditioning unit advice wanted Martin UK diy 25 August 14th 03 01:10 PM


All times are GMT +1. The time now is 03:53 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"