Hi,

I was wandering if any one here has had a go at DIY installing central
heating ? Thinking I could consider doing this in my next house. I have
plumbed my kitchen and bathroom before and I quite enjoyed it . I
guess there would be alot of moving stuff around, ripping up
floorboards and soldering pipes etc , but assuming I left the gas stuff
to a pro. it wouldn't be too tricky would it ? I guess that isntalling
the pipes and rads is what would cost the most to get done. The house
I was looking at is 3 bed detached, it just needs central heating doing
mainly ( and a kitchen maybe) !!

Simon

  #2   Report Post  
kmillar
 
Posts: n/a
Default

Hi Simon,
I recently installed a full CH system, two zones. (HW and CH) using a
sealed system, and a BAXI 'system' boiler.
Prior to this I had done a few bathrooms and kitchens.

It turned out to be lots more work than I expected, basically due to
the limited space for working under floors, it took a lot longer to do
the pipework. Plus I was working alone.

Make sure you understand exactly what you need (especially legal
requirments of flue location etc), do you want a Combi? Condesing
boiler? Two zone? Sealed system or Vented?

To help you decide, go to any boiler manufacturers website that allows
you to download installer manuals (baxi is one) and make sure you fully
understand the installation instructions.

Remeber there will be some wiring to do too.

However, it is possible, and I now have a fully satisfactory and
working CH system in my 3 bedroom semi. Although it was hard work, and
at times I could have seen it far enough, but now I'm proud of my
achievment.

  #3   Report Post  
 
Posts: n/a
Default

Thansk for that, I think I might enjoy a project like that!

Simon

  #4   Report Post  
John
 
Posts: n/a
Default


"kmillar" wrote in message
oups.com...
Hi Simon,
I recently installed a full CH system, two zones. (HW and CH) using a
sealed system, and a BAXI 'system' boiler.
Prior to this I had done a few bathrooms and kitchens.

It turned out to be lots more work than I expected, basically due to
the limited space for working under floors, it took a lot longer to do
the pipework. Plus I was working alone.

Make sure you understand exactly what you need (especially legal
requirments of flue location etc), do you want a Combi? Condesing
boiler? Two zone? Sealed system or Vented?

To help you decide, go to any boiler manufacturers website that allows
you to download installer manuals (baxi is one) and make sure you fully
understand the installation instructions.

Remeber there will be some wiring to do too.

However, it is possible, and I now have a fully satisfactory and
working CH system in my 3 bedroom semi. Although it was hard work, and
at times I could have seen it far enough, but now I'm proud of my
achievment.


The OP doesn't seem to have read the FAQ:-(

There are various odds and ends to beware of as noted above some of which
are obvious and some of which aren't. For instance I had a d-i-yer on the
phone last night asking if I could explain why his self install rads with
y-plan control got appreciably warm when hot water only was selected. It
turned out he had used the same return pipe for everything as it passed
instead of a return for the hot water only and a seperate return for the
rads with connection of the two close to the boiler. Pipe pressure drop was
sufficient to cause parasitic circulation. We managed to sort out his next
course of action over the phone which considering the weather here last
night I was pleased about.

Oh and IMHO he ought to look at Glow Worm boilers instead of Bxxx


Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Complicated central Heating; Back-Boiler and Combi-Boiler tfc715 UK diy 1 February 3rd 05 05:30 PM
Heating design diagram (preliminary) John Aston UK diy 55 December 10th 04 08:31 PM
Central Heating and Hot Water not working properly together [email protected] UK diy 2 October 19th 04 10:31 AM
Pool water in central heating system Andy Hall UK diy 1 September 2nd 03 05:01 PM
Further to my last post entitled 'Flushing and treating central heating question' David W.E. Roberts UK diy 0 July 29th 03 07:15 PM


All times are GMT +1. The time now is 01:38 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"