Home |
Search |
Today's Posts |
|
UK diy (uk.d-i-y) For the discussion of all topics related to diy (do-it-yourself) in the UK. All levels of experience and proficency are welcome to join in to ask questions or offer solutions. |
Reply |
|
LinkBack | Thread Tools | Display Modes |
#1
|
|||
|
|||
Baxi Boiler annoyance
Hi,
I have a Baxi combi boiler 80e and I'm having problems. It's been dodgy for the past two weeks. I have had to keep the clock on 'constant', then the heating would fire up for a little while then switch off, then fire up again, switch off etc. This was not ideal, but kept the house warm. Today it won't work at all. The pilot will light, I get the initial 'click n whoosh' thing, and can see the burner lighting, but then it will just go out. The power and heating green leds stay on, but the flame warning light then flashes. The pressure is fine - 1.5. I also can't get any hot water. I've been resetting it, switching it off, etc for hours now with no joy. Does anyone know if there's anything I can do myself to get it working again? I'm assuming it's not the thermal coupling,as I read somewhere that it wouldn't even light if the thermalcoupling was gone? (I know I might be wrong here) I can't afford a heating engineer until I get paid at the end of the month. I'm freezing, so any help would be greatly appreciated.. Thanks for reading.. I hope someone can help me out. lemonpillows x |
#2
|
|||
|
|||
"lemonpillows" wrote in message .. . Hi, I have a Baxi combi boiler 80e and I'm having problems. It's been dodgy for the past two weeks. I have had to keep the clock on 'constant', then the heating would fire up for a little while then switch off, then fire up again, switch off etc. This was not ideal, but kept the house warm. Today it won't work at all. The pilot will light, I get the initial 'click n whoosh' thing, and can see the burner lighting, but then it will just go out. The power and heating green leds stay on, but the flame warning light then flashes. The pressure is fine - 1.5. I also can't get any hot water. I've been resetting it, switching it off, etc for hours now with no joy. Does anyone know if there's anything I can do myself to get it working again? I'm assuming it's not the thermal coupling,as I read somewhere that it wouldn't even light if the thermalcoupling was gone? (I know I might be wrong here) I can't afford a heating engineer until I get paid at the end of the month. I'm freezing, so any help would be greatly appreciated.. Thanks for reading.. I hope someone can help me out. lemonpillows x Is the pump running? Bob |
#3
|
|||
|
|||
On this boiler there are diagnostics. If it were the pump then the light flashing would be the one which looks like a circle with a cross through it, that represents the pump. I think that the flashing light you have indicates a problem with the main burner. There is a flame proving circuit known as a flame rectification. There are various electrical leeds between the burner compartment and the pcb (just behind the plastic backing to the pull down front flap). One leed is the Ht leed which lights the gas and the others conduct a direct current. The flame acts as a diode allowing current to pass in one direction, if there is no flame there is no current and the boiler goes into lockout. In your case there is an initial flame, and the warning light you are getting implies perhaps something as simple as a leed has come off or is shorting out. Check that and get back.
Paul |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Baxi Boiler shutting down | UK diy | |||
Baxi WM 381 RS Boiler Blowing Fuse | UK diy | |||
Near death boiler + replacing a boiler | UK diy | |||
Old Baxi WM 531 RS boiler problem | UK diy | |||
Baxi Bermuda boiler | UK diy |