The pilot light on my 25yr old, gloworm, wall mounted boiler has been
continually blowing out this winter. Well naturally it blew out last night as it was bloody windy here in Notts! It has always been a bit prone to this as the flue exits to a pretty draughty corridor between two houses. It seems to be worse than ever this year. Has anybody had a similar problem and found a solution? (short of resiting the boiler!) Thanks, hope everyone escaped without storm damage! Keith |
#2
|
|||
|
|||
In article ,
Keith Oliver wrote: The pilot light on my 25yr old, gloworm, wall mounted boiler has been continually blowing out this winter. Well naturally it blew out last night as it was bloody windy here in Notts! It has always been a bit prone to this as the flue exits to a pretty draughty corridor between two houses. It seems to be worse than ever this year. Has anybody had a similar problem and found a solution? (short of resiting the boiler!) If the pilot light is smaller than spec it may well blow out more easily. Dunno your model, but they're usually easy enough to remove and clean. Something like cellulose thinners or car carburettor cleaner will usually shift any deposits. -- *They call it PMS because Mad Cow Disease was already taken. Dave Plowman London SW To e-mail, change noise into sound. |
#3
|
|||
|
|||
I removed the jet, cleaned and blew throught it. The pilot flame is now
much stonger and bluer. Thanks Dave. I also took the opportunity to remove the flue cover and inspect the flue from inside. The flue cover had some sealant deposits around the edges, should I replace this, if so with what? Thank all.. |
#4
|
|||
|
|||
In article ,
"Dave Plowman (News)" writes: In article , Keith Oliver wrote: The pilot light on my 25yr old, gloworm, wall mounted boiler has been continually blowing out this winter. Well naturally it blew out last night as it was bloody windy here in Notts! It has always been a bit prone to this as the flue exits to a pretty draughty corridor between two houses. It seems to be worse than ever this year. Has anybody had a similar problem and found a solution? (short of resiting the boiler!) If the pilot light is smaller than spec it may well blow out more easily. Dunno your model, but they're usually easy enough to remove and clean. If it does need cleaning, it's probably a good indication the whole boiler may need cleaning and a service. Has it been done recently? -- Andrew Gabriel |
#5
|
|||
|
|||
"Andrew Gabriel" wrote in message ... In article , "Dave Plowman (News)" writes: In article , Keith Oliver wrote: The pilot light on my 25yr old, gloworm, wall mounted boiler has been continually blowing out this winter. Well naturally it blew out last night as it was bloody windy here in Notts! It has always been a bit prone to this as the flue exits to a pretty draughty corridor between two houses. It seems to be worse than ever this year. Has anybody had a similar problem and found a solution? (short of resiting the boiler!) Seems to be a standard problem with Gloworms of this age, like mine, but new pilot assemblies are available on the web. There's a lot of asbestos fibre around the housing too ! |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
boiler / central heating problem - main burner weak and cuts out | UK diy | |||
Near death boiler + replacing a boiler | UK diy | |||
Myson Apollo boiler: No pilot light. | UK diy | |||
Gas boiler service review/advice | UK diy | |||
Boiler pilot light went out | UK diy |