  #1   Report Post  
r.p.mcmurphy
 
Posts: n/a
Default Spots for zone 2?

doing me bathroom up. swmbo wants halogen spots...b&q have some suitable
for zone 3...but it looks like i need em for zone 2. am ordering from TLC a
pull cord dimmer so would like to order from them. are low voltage spots
zone 2 compatible?

Steve


  #2   Report Post  
Mike
 
Posts: n/a
Default


"r.p.mcmurphy" wrote in message
...
doing me bathroom up. swmbo wants halogen spots...b&q have some suitable
for zone 3...but it looks like i need em for zone 2. am ordering from TLC

a
pull cord dimmer so would like to order from them. are low voltage spots
zone 2 compatible?



Most say not but I cannot work out why. I took a typical electronic
transformer apart and it seemed adequately insulated. But if you get a
proper transformer instead (e.g. Wickes) then I can't see how it won't be
compatible.


  #3   Report Post  
John Rumm
 
Posts: n/a
Default

r.p.mcmurphy wrote:

doing me bathroom up. swmbo wants halogen spots...b&q have some suitable
for zone 3...but it looks like i need em for zone 2. am ordering from TLC a
pull cord dimmer so would like to order from them. are low voltage spots
zone 2 compatible?


You ought to get IP65 rated spots:

http://www.tlc-direct.co.uk/Main_Ind...gen/index.html

These will resist even direct water jets.

They can go in zone 2 (or Zone 1 even since they meet the regs
requirment of SELV and IPX4 or better).

--
Cheers,

John.

/================================================== ===============\
| Internode Ltd - http://www.internode.co.uk |
|-----------------------------------------------------------------|
| John Rumm - john(at)internode(dot)co(dot)uk |
\================================================= ================/
  #4   Report Post  
John Rumm
 
Posts: n/a
Default

Mike wrote:

Most say not but I cannot work out why. I took a typical electronic
transformer apart and it seemed adequately insulated. But if you get a
proper transformer instead (e.g. Wickes) then I can't see how it won't be
compatible.


Point your shower at it.... if the fitting fills up with water and the
bulb goes bang (perhaps even showering you with hot glass in the
process), then you can be fairly safe in assuming it was not compatible ;-)

The issue is more one of the fitting being waterproof, rather than the
voltage being dangerous. Having said that you may find a good many
transformers are not intended to offer any protection from water, so if
the fitting lets water past, and you have a local transformer with mains
on the other side of it stuck in close proximity to the fitting, then
you have a problem with the electrical side as well.


--
Cheers,

John.

/================================================== ===============\
| Internode Ltd - http://www.internode.co.uk |
|-----------------------------------------------------------------|
| John Rumm - john(at)internode(dot)co(dot)uk |
\================================================= ================/
  #5   Report Post  
Mike
 
Posts: n/a
Default


"John Rumm" wrote in message
...
Mike wrote:

Most say not but I cannot work out why. I took a typical electronic
transformer apart and it seemed adequately insulated. But if you get a
proper transformer instead (e.g. Wickes) then I can't see how it won't

be
compatible.


Point your shower at it.... if the fitting fills up with water and the
bulb goes bang (perhaps even showering you with hot glass in the
process), then you can be fairly safe in assuming it was not compatible

;-)

The issue is more one of the fitting being waterproof, rather than the
voltage being dangerous. Having said that you may find a good many
transformers are not intended to offer any protection from water, so if
the fitting lets water past, and you have a local transformer with mains
on the other side of it stuck in close proximity to the fitting, then
you have a problem with the electrical side as well.



But the typical 12volt halogen works underwater - my pond is full of them.



Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Really odd spots on laundry... what's the deal? Engwar Home Repair 11 October 21st 04 10:30 PM
Flat roof -- covering holes and soft spots? Neil Covington Home Repair 3 September 21st 04 04:19 PM
spots on new laminate floors Ninip Home Repair 4 February 16th 04 09:57 PM
oily spots on clothes from washer Kathy Ober Home Ownership 2 August 29th 03 09:39 PM


All times are GMT +1. The time now is 10:45 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"