![]() "Set Square" wrote in message ... In an earlier contribution to this discussion, Mark Trueman wrote: Hi, Current system - gravity HW, pumped CH. HW must be on for CH to be on. Runs off a Drayton Lifestyle LP241 timer. No stats or TRVs on rads, when its on, its on full blast. Anyway, im thinking about adding a room stat to try to control the temp a bit better. Didnt mind it getting to 25 degrees previously, but now my new marine fish tank is not liking the increase in room temp. Anyway, i digress. Looking at installing the Drayton Digistat 2. Looks easy enough to wire up from looking at the LP241 instructions. What i want to know is; is there a better/cheaper alternative room stat (24 hour version is fine, 7 day version is even better). And if there is, is the wiring likely to be the same? Regards Mark With your existing setup, all you can really do with a room stat is switch the pump on and off - so, whenever heating is selected by the main programmer, the boiler will cycle on its own stat - and the DHW will continue to get hot(ter) by gravity circulation. Which i think it does now anyway, we tend to set the boiler to "1" (its an old baxi back boiler), and let it heat the water as it sees fit. If i install the stat, is this no longer going to happen? A room stat will help to stop the house from getting too hot - but it won't prevent the boiler from wasting engergy by cycling needlessly, nor will it prevent the DHW from overheating. If you're wishing to improve the overall control of your system, you should seriously consider installing a zone valve in the gravity HW circuit and a cylinder stat on the hot water cylinder, in order to convert it into a C-Plan system. [See http://content.honeywell.com/uk/homes/systems.htm ] This will provide a boiler interlock to ensure that the boiler only runs when needed - and will provide much better control over DHW temperature. Will look into this, thanks. Picked up a Digistat 3 tonight, going to fit it at the weekend Mark |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Combi Boiler and Room Thermostats | UK diy | |||
Update: Adding a wireless room thermostat (help needed) | UK diy |