Home |
Search |
Today's Posts |
|
UK diy (uk.d-i-y) For the discussion of all topics related to diy (do-it-yourself) in the UK. All levels of experience and proficency are welcome to join in to ask questions or offer solutions. |
Reply |
|
LinkBack | Thread Tools | Display Modes |
#1
Posted to uk.d-i-y
|
|||
|
|||
Compulsary New Radiators
I have lived alone in a three bedroomed association house for 17 years and
now there is a plan to replace all the storage heaters with a hot water system. This seems to be initiated by a government directive to make home heating more efficient by using a heat pipe. Any efficiency gain would obviously be lost by transmitting heat using water, rather than direct electricity. I am proposing that the installation of new radiators are fitted behind inward opening doors in the bedrooms and living room, this is all dead wall space and doesn't interfere with existing fitments. The upstairs landing will be housing the electric boiler and would facililitate short runs of pipework to the bedrooms, making a cleaner, more compact job. My wife, who lives in the next village has had such a conversion, but with gas as the heat source instead of electricity. This keeps breaking down and the (engineer) has to come out to fiddle with the boiler, at least a couple of dozen times now since 2019. Question: Does the team think that putting the heaters behind the doors would have any detrimental effect on heat distribution. All the storage heaters are under windows at the moment, so immediately lose a huge amount of heat, although double glazed. Best regards |
#3
Posted to uk.d-i-y
|
|||
|
|||
Compulsary New Radiators
On 13/01/2021 06:01, Funny Lingus wrote:
I have lived alone in a three bedroomed association house for 17 years and now there is a plan to replace all the storage heaters with a hot water system. This seems to be initiated by a government directive to make home heating more efficient by using a heat pipe. Any efficiency gain would obviously be lost by transmitting heat using water, rather than direct electricity. I am proposing that the installation of new radiators are fitted behind inward opening doors in the bedrooms and living room, this is all dead wall space and doesn't interfere with existing fitments. The upstairs landing will be housing the electric boiler and would facililitate short runs of pipework to the bedrooms, making a cleaner, more compact job. My wife, who lives in the next village has had such a conversion, but with gas as the heat source instead of electricity. This keeps breaking down and the (engineer) has to come out to fiddle with the boiler, at least a couple of dozen times now since 2019. Question: Does the team think that putting the heaters behind the doors would have any detrimental effect on heat distribution. All the storage heaters are under windows at the moment, so immediately lose a huge amount of heat, although double glazed. Best regards The reason for radiators under windows is that you get a cold downward draft from the window which even in a well heated room makes your feet feel cold and you perceive that the room is much colder than it actually is. Putting a radiator under the window counteracts this downward cold draft. If the housing association is proposing air sourced heat pumps then be prepared for much larger radiators. -- mailto : news {at} admac {dot} myzen {dot} co {dot} uk |
#4
Posted to uk.d-i-y
|
|||
|
|||
Compulsary New Radiators
On 13/01/2021 08:23, Brian Gaff (Sofa) wrote:
Not sure they should be compulsory, I use Storage heaters and have been pleased with them except for the clunky mechanical louvers getting stuck occasionally. I thought the whole idea was eventually to use a reversible heat pump and then it could be more efficient. Brian The OP suggested that a "heat pipe" was going to be installed along with an electric boiler so I assume that maybe he was referring to a heat pump (air sourced). He doesn't mention cost but possibly no change from £10k. -- mailto : news {at} admac {dot} myzen {dot} co {dot} uk |
#5
Posted to uk.d-i-y
|
|||
|
|||
Compulsary New Radiators
In article , Owain
Lastname wrote: On Wednesday, 13 January 2021 at 06:01:57 UTC, Funny Lingus wrote: Question: Does the team think that putting the heaters behind the doors would have any detrimental effect on heat distribution. All the storage heaters are under windows at the moment, so immediately lose a huge amount of heat, although double glazed. British Standard 5449 "(Central Heating) Forced circulation hot water heating systems for domestic premises" recommends: "Wherever practicable individual heat emitters (other than fan convectors) should be located on outside walls preferably beneath windows to offset the cooling effect: it is an advantage to choose an emitter of such a length that it occupies the full width of the window." My experience is that installers now prefer to put radiators on internal walls ostensibly to reduce heat loss but I think it's actually because it uses a lot less pipe. When we moved into this house' over 40 years ago, we found the radiators in the new extension were in the middle of two no-window walls. Basically, nowhere to put furniture such as bookcase or piano. I capped off one feed and extended the other to under the window. Had to do it on the surface since the room has a concrete floor. The rest of the house has suspended wooded floors. [Snip] -- from KT24 in Surrey, England "I'd rather die of exhaustion than die of boredom" Thomas Carlyle |
#6
Posted to uk.d-i-y
|
|||
|
|||
Compulsary New Radiators
On Wed, 13 Jan 2021 01:07:07 -0800, Owain Lastname wrote:
On Wednesday, 13 January 2021 at 06:01:57 UTC, Funny Lingus wrote: Question: Does the team think that putting the heaters behind the doors would have any detrimental effect on heat distribution. All the storage heaters are under windows at the moment, so immediately lose a huge amount of heat, although double glazed. British Standard 5449 "(Central Heating) Forced circulation hot water heating systems for domestic premises" recommends: "Wherever practicable individual heat emitters (other than fan convectors) should be located on outside walls preferably beneath windows to offset the cooling effect: it is an advantage to choose an emitter of such a length that it occupies the full width of the window." My experience is that installers now prefer to put radiators on internal walls ostensibly to reduce heat loss but I think it's actually because it uses a lot less pipe. They also like radiators back-to-back on the same wall for the same reason. A housing association job in an occupied property will try to be the quickest, easiest, (cheapest) least disruptive job possible. Storage heaters shouldn't be on external walls because of their far greater heat loss to the back of the heater. In larger rooms I would push for two radiators where possible. I had a grant-assisted heating system put in last year and the installers hated me. They wanted a quick easy cheap install with pipes going across the hall ceiling, only to find that all my cornicing has cabling inside it. (Concrete floor and ceiling in a flat.) So they ended up with long 22mm pipe runs round the entire perimeter of the building. I regard this as useful background heat even if the radiators are off. Also watch them installing them because they seem to default to minmum spacing off the wall to look "neater". I made tnem turn the wall brackets round to space radiators further off the external walls. Overall the job wasn't what I'd have wanted if I was paying for it all myself but a new gas supply, boiler and 6 rads for £1100 all in was a bargain. Owain Thanks Owain, useful info there in your note. |
#7
Posted to uk.d-i-y
|
|||
|
|||
Compulsary New Radiators
On 13/01/2021 08:55, alan_m wrote:
The reason for radiators under windows is that you get a cold downward draft from the window which even in a well heated room makes your feet feel cold and you perceive that the room is much colder than it actually is. Putting a radiator under the window counteracts this downward cold draft. The main reason is that it's generally otherwise unused space. -- Cheers Clive |
#8
Posted to uk.d-i-y
|
|||
|
|||
Compulsary New Radiators
On 13/01/2021 08:55, alan_m wrote:
On 13/01/2021 06:01, Funny Lingus wrote: I have lived alone in a three bedroomed association house for 17 years and now there is a plan to replace all the storage heaters with a hot water system. This seems to be initiated by a government directive to make home heating more efficient by using a heat pipe. Any efficiency gain would obviously be lost by transmitting heat using water, rather than direct electricity. I am proposing that the installation of new radiators are fitted behind inward opening doors in the bedrooms and living room, this is all dead wall space and doesn't interfere with existing fitments. The upstairs landing will be housing the electric boiler and would facililitate short runs of pipework to the bedrooms, making a cleaner, more compact job. My wife, who lives in the next village has had such a conversion, but with gas as the heat source instead of electricity. This keeps breaking down and the (engineer) has to come out to fiddle with the boiler, at least a couple of dozen times now since 2019. Question: Does the team think that putting the heaters behind the doors would have any detrimental effect on heat distribution. All the storage heaters are under windows at the moment, so immediately lose a huge amount of heat, although double glazed. The reason for radiators under windows is that you get a cold downward draft from the window which even in a well heated room makes your feet feel cold and you perceive that the room is much colder than it actually is. Putting a radiator under the window counteracts this downward cold draft. I think that's much less important with double glazing and better wall insulation as there won't be such a temperature gradient across the room. -- Max Demian |
#9
Posted to uk.d-i-y
|
|||
|
|||
Compulsary New Radiators
On 13/01/2021 06:01, Funny Lingus wrote:
I have lived alone in a three bedroomed association house for 17 years and now there is a plan to replace all the storage heaters with a hot water system. This seems to be initiated by a government directive to make home heating more efficient by using a heat pipe. Any efficiency gain would obviously be lost by transmitting heat using water, rather than direct electricity. The main problem with this scheme is that turning electricity into heat in a resistor is an incredibly *wasteful* way to do it. Heat pump is a much better approach (although they have maintenance issues too much more so than a gas or oil boiler). The "green" initiative to make all heating electric is conceptually flawed. We barely have enough electricity generating capacity as it is. Turning high grade electricity directly into low grade thermal heat is about the dumbest possible way of doing it. Any other means is preferable in terms of overall end to end energy efficiency. Add in a few more electric cars and we will be tipped over the edge - particularly in winter when it is cloudy and the wind isn't blowing! I am proposing that the installation of new radiators are fitted behind inward opening doors in the bedrooms and living room, this is all dead wall space and doesn't interfere with existing fitments. The upstairs landing will be housing the electric boiler and would facililitate short runs of pipework to the bedrooms, making a cleaner, more compact job. Modern approach would be to put radiators on internal walls so that any heat going through the wall stays in the house. Old style they tended to put them under the windows to mask cold drafts coming down off the windows. Decent double makes quite a difference here. My wife, who lives in the next village has had such a conversion, but with gas as the heat source instead of electricity. This keeps breaking down and the (engineer) has to come out to fiddle with the boiler, at least a couple of dozen times now since 2019. There is no reason why a correctly installed gas boiler should break down so often. They need one annual maintenance if you play by the book but I know plenty of people who never seem to bother. Likewise for oil fired although that can be a bit tetchy if you get a gale with the wind in the wrong direction. Question: Does the team think that putting the heaters behind the doors would have any detrimental effect on heat distribution. All the storage heaters are under windows at the moment, so immediately lose a huge amount of heat, although double glazed. You will notice some cold drafts coming down from the windows and making the floor level colder. That was the old rationale for putting radiators in front of the windows. The aluminium faced polystyrene foam sheets placed behind the radiators prevent losses through the wall very well. -- Regards, Martin Brown |
#10
Posted to uk.d-i-y
|
|||
|
|||
Compulsary New Radiators
On Wed, 13 Jan 2021 10:31:41 +0000, Martin Brown wrote:
On 13/01/2021 06:01, Funny Lingus wrote: I have lived alone in a three bedroomed association house for 17 years and now there is a plan to replace all the storage heaters with a hot water system. This seems to be initiated by a government directive to make home heating more efficient by using a heat pipe. Any efficiency gain would obviously be lost by transmitting heat using water, rather than direct electricity. The main problem with this scheme is that turning electricity into heat in a resistor is an incredibly *wasteful* way to do it. Heat pump is a much better approach (although they have maintenance issues too much more so than a gas or oil boiler). The "green" initiative to make all heating electric is conceptually flawed. We barely have enough electricity generating capacity as it is. Turning high grade electricity directly into low grade thermal heat is about the dumbest possible way of doing it. Any other means is preferable in terms of overall end to end energy efficiency. Add in a few more electric cars and we will be tipped over the edge - particularly in winter when it is cloudy and the wind isn't blowing! I am proposing that the installation of new radiators are fitted behind inward opening doors in the bedrooms and living room, this is all dead wall space and doesn't interfere with existing fitments. The upstairs landing will be housing the electric boiler and would facililitate short runs of pipework to the bedrooms, making a cleaner, more compact job. Modern approach would be to put radiators on internal walls so that any heat going through the wall stays in the house. Old style they tended to put them under the windows to mask cold drafts coming down off the windows. Decent double makes quite a difference here. My wife, who lives in the next village has had such a conversion, but with gas as the heat source instead of electricity. This keeps breaking down and the (engineer) has to come out to fiddle with the boiler, at least a couple of dozen times now since 2019. There is no reason why a correctly installed gas boiler should break down so often. They need one annual maintenance if you play by the book but I know plenty of people who never seem to bother. Likewise for oil fired although that can be a bit tetchy if you get a gale with the wind in the wrong direction. Question: Does the team think that putting the heaters behind the doors would have any detrimental effect on heat distribution. All the storage heaters are under windows at the moment, so immediately lose a huge amount of heat, although double glazed. You will notice some cold drafts coming down from the windows and making the floor level colder. That was the old rationale for putting radiators in front of the windows. The aluminium faced polystyrene foam sheets placed behind the radiators prevent losses through the wall very well. I think a very high capacity Lithium battery would add to the cost/ effectiveness so it could be charged off peak and the main storage radiator turned on later in the day. |
#11
Posted to uk.d-i-y
|
|||
|
|||
Compulsary New Radiators
On 13/01/2021 10:58, jon wrote:
I think a very high capacity Lithium battery would add to the cost/ effectiveness so it could be charged off peak and the main storage radiator turned on later in the day. It would also more than double the installation costs and in all probability have a working life in regular use of at most a decade. https://www.bbc.co.uk/news/technology-55337192 Thermal store is the least bad option if you must do it this way. UK's big problem right now is not enough electricity generating capacity in winter going forwards. It will only take a calm blocking high and the most of Europe becalmed and we will be having electricity rationing. Solar is pathetic on grey winters days with the sun barely above the horizon even if the clouds do part for an hour or so. -- Regards, Martin Brown |
#12
Posted to uk.d-i-y
|
|||
|
|||
Compulsary New Radiators
alan_m wrote:
On 13/01/2021 08:23, Brian Gaff (Sofa) wrote: Not sure they should be compulsory, I use Storage heaters and have been pleased with them except for the clunky mechanical louvers getting stuck occasionally. I thought the whole idea was eventually to use a reversible heat pump and then it could be more efficient. Brian The OP suggested that a "heat pipe" was going to be installed along with an electric boiler so I assume that maybe he was referring to a heat pump (air sourced). He doesn't mention cost but possibly no change from £10k. Heat pipes are amazing. They use phase change (vapor changing back to fluid, releasing the heat of vaporization) as a transport mechanism. Some hobbyist computers have heatpipes in the CPU heatsink, and the transport mechanism is so powerful, it has better thermal conduction properties than an equivalent diameter of solid copper. That's because it is an active transport, whereas solid copper is merely a passive transport. https://en.wikipedia.org/wiki/Heat_pipe Heatpipes don't have to be expensive to work. They can also "work uphill", if the inside surface of the plumbing is "sintered" and the capillary action that results, allows condensed fluid to travel uphill. A more preferred situation, is for the condensed fluid to flow downhill back to the heat source (storage heater). You could do this: In the diagram, the working fluid in the storage heater (water), does not mix with the working fluid in the heatpipe (pure alcohol). The entire heatpipe only has a few teaspoons of alcohol. It does not have, nor need, gallons of alcohol. The transport is vapor phase, and little vapor is needed. +-+ | +== Radiator +-------------+ heat pipe | +== | |+------------------------+ +== | Storage || +-----------------------+ | heater || | (hollow) condenses | |+--+ +-------------+ Makes alcohol [Vapor phase transport] vapor The benefit is, you don't need the storage tank in the upstairs room. Now, the problem with placing a heatpump on the left hand side of that picture, is the need for winter heating and summer cooling, to work with the same gubbins. In principle, I think you could make it work. But... it might not have the degree of efficiency desired. If I only had to set it up for one season (only for winter heating), I could make it work slightly better. Just as the general discussion of heatpumps leaves me cold. Heatpumps are a low quality heat source, requiring extraordinary efforts to transfer the heat into a room. Adding a heatpipe to the picture, is just additional aggravation, making a "marginal situation", "more marginal". Stupid even. The electric storage heater, the electric part is "high quality" heat. When you couple it with the storage part, that degrades the quality a bit. If the water cools down to 40C, what do you do with the remaining heat ? That's not a high enough temp to really heat the room any more. Heatpipes have a design power limit. For example, if you put more than 200W into the CPU heatsink, all of the working fluid in the pipes remains in the vapor phase, and the nice thermal pumping action stops. The idea then, is to ensure the heatpipe is big enough, for the application, so it doesn't "saturate". Heatpipes have apparently already been used in air-to-air heat exchangers for R2000 homes. But I haven't seen any pictures of working units of that type, so I don't know what the implementation looks like. Paul |
#13
Posted to uk.d-i-y
|
|||
|
|||
Compulsary New Radiators
Funny Lingus wrote:
I have lived alone in a three bedroomed association house for 17 years and now there is a plan to replace all the storage heaters with a hot water system. This seems to be initiated by a government directive to make home heating more efficient by using a heat pipe. Any efficiency gain would obviously be lost by transmitting heat using water, rather than direct electricity. Do you have mains gas? What is the state of your insulation? - cavity walls? insulated? - loft insulation? How thick? - double glazing? - draught proofing? - air bricks? ASHP can be 2-4x as efficient as pure electric heat so, while there are losses in a wet system, they are likely to be overridden by the heat pump efficiency. On the other hand, if your house is poorly insulated the heat pump may not be able to keep up (unless you fit a huge one, which is costly). (ASHP can struggle in freezing weather, but it's hard not to beat pure electric heat) I am proposing that the installation of new radiators are fitted behind inward opening doors in the bedrooms and living room, this is all dead wall space and doesn't interfere with existing fitments. The upstairs landing will be housing the electric boiler and would facililitate short runs of pipework to the bedrooms, making a cleaner, more compact job. It depends on the heating system as to the flow temperature. I'd expect that putting a radiator behind a door is going to be less effective if you leave the door open most of the time. Obviously it'll put heat into the room eventually (nowhere else for it to go), but spend a while heating up the door first. My wife, who lives in the next village has had such a conversion, but with gas as the heat source instead of electricity. This keeps breaking down and the (engineer) has to come out to fiddle with the boiler, at least a couple of dozen times now since 2019. That sounds like a regular wet system with a gas boiler, as used by millions of people. They don't keep breaking down, which suggests some problem with the (quality of the) installation. Was that fitted by the same HA? Theo |
#14
Posted to uk.d-i-y
|
|||
|
|||
Compulsary New Radiators
On Wed, 13 Jan 2021 10:30:02 +0000, Max Demian wrote:
Question: Does the team think that putting the heaters behind the doors would have any detrimental effect on heat distribution. All the storage heaters are under windows at the moment, so immediately lose a huge amount of heat, although double glazed. The reason for radiators under windows is that you get a cold downward draft from the window which even in a well heated room makes your feet feel cold and you perceive that the room is much colder than it actually. Putting a radiator under the window counteracts this downward cold draft. I think that's much less important with double glazing and better wall insulation as there won't be such a temperature gradient across the room. It's not so much a temperature gradient across the room as air ciculation. The windows, double or single glazed, will cool the air this becomes more dense and sinks drawing warmer air down. This sets up a circulation, the bottomm line being your feet are in a cold draft. Decent curtains outside the window reveal and tucked behind the top of the radiator keep the warm air in and any circulation within the reveal. Even better if you can fit another set of curtains adjacent to the windows. Behind doors strikes me as a really bad place for a radiator. Are doors habitually left open or closed? Open is going to restrict how much heat the raditor can effectively transfer to the room. Will there be enough space for a radiator to fit without fouling the door when it is open?. Doors tend to be opposite windows, this will enhance the circulation due to the window cooling effect. -- Cheers Dave. |
#15
Posted to uk.d-i-y
|
|||
|
|||
Compulsary New Radiators
On Wed, 13 Jan 2021 06:01:52 -0000, Funny Lingus wrote:
... now there is a plan to replace all the storage heaters with a hot water system. This seems to be initiated by a government directive to make home heating more efficient by using a heat pipe. What do you mean by "heat pipe"? Do you mean some form of heat pump or a massive central communal boiler feeding hot water to individual properties? Any efficiency gain would obviously be lost by transmitting heat using water, rather than direct electricity. Old, and at 17 years, yours are "old", storeage heaters aren't particulary good, they leak to much heat during the day and can't cope with a sudden cold snap. A wet system heated by electricity as a replacement does seem a bit cock eyed. Though remember any "lost" heat from the pipework/boiler is still within the property. The upstairs landing will be housing the electric boiler and would facililitate short runs of pipework to the bedrooms, making a cleaner, more compact job. Is that a boiler just for domestic hatowater or a heating boiler? Space heating requires a lot of power, you have storeage heaters already so your (E7?) supply should be up to it. But you'll need a preety large tank of water to store enough heat to heat the place sensibly through the day. Unless the system forces you to use electricity through the day for space heating. That is likely to be expensive(*). I'd have thought that just replacing the old storeage heaters with modern "high heat rention" ones would be a far better option. They aren't cheap though, I suspect the proposed wet system would be cheaper... (*) Depending on your E7 tarrif. Just switched our E7 to one that charges the same per unit day or night. The bill will go up but only inline with normal increases. The night unit price has gone up and the day unit down. I'm paying less per unit on the E7 supply than I am for the ordinary supply. 10.566 p/unit v 14.024 p/unit (+ 5% VAT). -- Cheers Dave. |
#16
Posted to uk.d-i-y
|
|||
|
|||
Compulsary New Radiators
On Wed, 13 Jan 2021 03:34:58 -0800 (PST), Owain Lastname wrote:
If your 'electric boiler' is going to be on peak rate electricity it may be 'greener' ie use less electricity overall, but it will cost you 3x the price of storage heaters to run and 5x the price of a mains gas boiler. Or not. I pay 10.566 p/unit 24/7 on an E7 tariff. That's only about 2x mains gas. Some housing associations (or their tenants) have been bitten badly by ill-advised 'eco' heating schemes that are lucrative for the scheme developers. +1 What the OP has posted sets off that alarm bell with me as well. -- Cheers Dave. |
#17
Posted to uk.d-i-y
|
|||
|
|||
Compulsary New Radiators
On Wed, 13 Jan 2021 11:36:56 +0000, Theo wrote:
Funny Lingus wrote: I have lived alone in a three bedroomed association house for 17 years and now there is a plan to replace all the storage heaters with a hot water system. This seems to be initiated by a government directive to make home heating more efficient by using a heat pipe. Any efficiency gain would obviously be lost by transmitting heat using water, rather than direct electricity. Do you have mains gas? No mains gas in village What is the state of your insulation? - cavity walls? insulated? yes - loft insulation? How thick? 12" - double glazing? yes - draught proofing? some internal doors - air bricks? Bathroom and kitchen ASHP can be 2-4x as efficient as pure electric heat so, while there are losses in a wet system, they are likely to be overridden by the heat pump efficiency. On the other hand, if your house is poorly insulated the heat pump may not be able to keep up (unless you fit a huge one, which is costly). (ASHP can struggle in freezing weather, but it's hard not to beat pure electric heat) I am proposing that the installation of new radiators are fitted behind inward opening doors in the bedrooms and living room, this is all dead wall space and doesn't interfere with existing fitments. The upstairs landing will be housing the electric boiler and would facililitate short runs of pipework to the bedrooms, making a cleaner, more compact job. It depends on the heating system as to the flow temperature. I'd expect that putting a radiator behind a door is going to be less effective if you leave the door open most of the time. Obviously it'll put heat into the room eventually (nowhere else for it to go), but spend a while heating up the door first. My wife, who lives in the next village has had such a conversion, but with gas as the heat source instead of electricity. This keeps breaking down and the (engineer) has to come out to fiddle with the boiler, at least a couple of dozen times now since 2019. That sounds like a regular wet system with a gas boiler, as used by millions of people. They don't keep breaking down, which suggests some problem with the (quality of the) installation. Was that fitted by the same HA? Theo |
#18
Posted to uk.d-i-y
|
|||
|
|||
Compulsary New Radiators
On 13/01/2021 06:01, Funny Lingus wrote:
I have lived alone in a three bedroomed association house for 17 years and now there is a plan to replace all the storage heaters with a hot water system. This seems to be initiated by a government directive to make home heating more efficient by using a heat pipe. Any efficiency gain would obviously be lost by transmitting heat using water, rather than direct electricity. I am proposing that the installation of new radiators are fitted behind inward opening doors in the bedrooms and living room, this is all dead wall space and doesn't interfere with existing fitments. The upstairs landing will be housing the electric boiler and would facililitate short runs of pipework to the bedrooms, making a cleaner, more compact job. My wife, who lives in the next village has had such a conversion, but with gas as the heat source instead of electricity. This keeps breaking down and the (engineer) has to come out to fiddle with the boiler, at least a couple of dozen times now since 2019. Question: Does the team think that putting the heaters behind the doors would have any detrimental effect on heat distribution. All the storage heaters are under windows at the moment, so immediately lose a huge amount of heat, although double glazed. Best regards You should tell the housing association to spend the money on better insulation and more modern storage heaters, which is *FAR* more cost effective. Fitting a new wet radiator system, heated by electricity to an existing (not perticularly new) property could only be dreamed up by a completely clueless greenie numpty. An utterly expensive folly, only made possible by the fact that they are spending other peoples taxes. |
#19
Posted to uk.d-i-y
|
|||
|
|||
Compulsary New Radiators
On 13/01/2021 09:55, charles wrote:
In article , Owain Lastname wrote: On Wednesday, 13 January 2021 at 06:01:57 UTC, Funny Lingus wrote: Question: Does the team think that putting the heaters behind the doors would have any detrimental effect on heat distribution. All the storage heaters are under windows at the moment, so immediately lose a huge amount of heat, although double glazed. British Standard 5449 "(Central Heating) Forced circulation hot water heating systems for domestic premises" recommends: "Wherever practicable individual heat emitters (other than fan convectors) should be located on outside walls preferably beneath windows to offset the cooling effect: it is an advantage to choose an emitter of such a length that it occupies the full width of the window." My experience is that installers now prefer to put radiators on internal walls ostensibly to reduce heat loss but I think it's actually because it uses a lot less pipe. When we moved into this house' over 40 years ago, we found the radiators in the new extension were in the middle of two no-window walls. Basically, nowhere to put furniture such as bookcase or piano. I capped off one feed and extended the other to under the window. Had to do it on the surface since the room has a concrete floor. The rest of the house has suspended wooded floors. [Snip] It should have a construction slab about 5 inches thick, topped with about 80mm of aerated screed which is easier to 'polish' to give a flat surface. You can (or should have been) able to dig a channel through the screed without a massive amount of effort. |
#20
Posted to uk.d-i-y
|
|||
|
|||
Compulsary New Radiators
On 13/01/2021 10:04, jon wrote:
On Wed, 13 Jan 2021 01:07:07 -0800, Owain Lastname wrote: On Wednesday, 13 January 2021 at 06:01:57 UTC, Funny Lingus wrote: Question: Does the team think that putting the heaters behind the doors would have any detrimental effect on heat distribution. All the storage heaters are under windows at the moment, so immediately lose a huge amount of heat, although double glazed. British Standard 5449 "(Central Heating) Forced circulation hot water heating systems for domestic premises" recommends: "Wherever practicable individual heat emitters (other than fan convectors) should be located on outside walls preferably beneath windows to offset the cooling effect: it is an advantage to choose an emitter of such a length that it occupies the full width of the window." My experience is that installers now prefer to put radiators on internal walls ostensibly to reduce heat loss but I think it's actually because it uses a lot less pipe. They also like radiators back-to-back on the same wall for the same reason. A housing association job in an occupied property will try to be the quickest, easiest, (cheapest) least disruptive job possible. Storage heaters shouldn't be on external walls because of their far greater heat loss to the back of the heater. In larger rooms I would push for two radiators where possible. I had a grant-assisted heating system put in last year and the installers hated me. They wanted a quick easy cheap install with pipes going across the hall ceiling, only to find that all my cornicing has cabling inside it. (Concrete floor and ceiling in a flat.) So they ended up with long 22mm pipe runs round the entire perimeter of the building. I regard this as useful background heat even if the radiators are off. Also watch them installing them because they seem to default to minmum spacing off the wall to look "neater". I made tnem turn the wall brackets round to space radiators further off the external walls. Overall the job wasn't what I'd have wanted if I was paying for it all myself but a new gas supply, boiler and 6 rads for £1100 all in was a bargain. Owain Thanks Owain, useful info there in your note. I don't believe it is possible to have gas installed, and entire boiler+rads+controls+pipes for £1100. £11,000 very possibly and half of that for providing gas to the property. |
#21
Posted to uk.d-i-y
|
|||
|
|||
Compulsary New Radiators
On 13/01/2021 12:16, Dave Liquorice wrote:
On Wed, 13 Jan 2021 03:34:58 -0800 (PST), Owain Lastname wrote: If your 'electric boiler' is going to be on peak rate electricity it may be 'greener' ie use less electricity overall, but it will cost you 3x the price of storage heaters to run and 5x the price of a mains gas boiler. Or not. I pay 10.566 p/unit 24/7 on an E7 tariff. That's only about 2x mains gas. As more and more coal and nuclear plants close, the availability of 'unwanted' off peak power diminishes. I suspect the only suitable replacement in future will the OctopusAgile tarriff that gives you advance notice of what your hourly rate will be so you can plan your usage. One of the Tims seems to have this tarriff. I would be interested to know what sort of hourly rate he was paying through the recent cold snap. The Octopus website only gives historical data up to about 6 months ago. Some housing associations (or their tenants) have been bitten badly by ill-advised 'eco' heating schemes that are lucrative for the scheme developers. +1 What the OP has posted sets off that alarm bell with me as well. ++1 |
#22
Posted to uk.d-i-y
|
|||
|
|||
Compulsary New Radiators
On 13/01/2021 11:36, Theo wrote:
Funny Lingus wrote: I have lived alone in a three bedroomed association house for 17 years and now there is a plan to replace all the storage heaters with a hot water system. This seems to be initiated by a government directive to make home heating more efficient by using a heat pipe. Any efficiency gain would obviously be lost by transmitting heat using water, rather than direct electricity. Do you have mains gas? What is the state of your insulation? - cavity walls? insulated? - loft insulation? How thick? - double glazing? - draught proofing? - air bricks? ASHP can be 2-4x as efficient as pure electric heat so, while there are losses in a wet system, they are likely to be overridden by the heat pump efficiency. On the other hand, if your house is poorly insulated the heat pump may not be able to keep up (unless you fit a huge one, which is costly). (ASHP can struggle in freezing weather, but it's hard not to beat pure electric heat) I am proposing that the installation of new radiators are fitted behind inward opening doors in the bedrooms and living room, this is all dead wall space and doesn't interfere with existing fitments. The upstairs landing will be housing the electric boiler and would facililitate short runs of pipework to the bedrooms, making a cleaner, more compact job. It depends on the heating system as to the flow temperature. I'd expect that putting a radiator behind a door is going to be less effective if you leave the door open most of the time. Obviously it'll put heat into the room eventually (nowhere else for it to go), but spend a while heating up the door first. My wife, who lives in the next village has had such a conversion, but with gas as the heat source instead of electricity. This keeps breaking down and the (engineer) has to come out to fiddle with the boiler, at least a couple of dozen times now since 2019. That sounds like a regular wet system with a gas boiler, as used by millions of people. They don't keep breaking down, which suggests some problem with the (quality of the) installation. Was that fitted by the same HA? Theo Does someone in the HA get kickbacks from the installer who quoted far more than he would get away with where a private customer is concerned ? |
#23
Posted to uk.d-i-y
|
|||
|
|||
Compulsary New Radiators
On 13/01/2021 12:11, Dave Liquorice wrote:
(*) Depending on your E7 tarrif. Just switched our E7 to one that charges the same per unit day or night. The bill will go up but only inline with normal increases. The night unit price has gone up and the day unit down. I'm paying less per unit on the E7 supply than I am for the ordinary supply. 10.566 p/unit v 14.024 p/unit (+ 5% VAT). Which company/tariff ? |
#24
Posted to uk.d-i-y
|
|||
|
|||
Compulsary New Radiators
|
#25
Posted to uk.d-i-y
|
|||
|
|||
Compulsary New Radiators
In article ,
alan_m wrote: The reason for radiators under windows is that you get a cold downward draft from the window which even in a well heated room makes your feet feel cold and you perceive that the room is much colder than it actually is. Putting a radiator under the window counteracts this downward cold draft. I was told it aids circulation in the room, evening up the temperature. Although suspect it was just a convenient place to put it in many rooms. -- *Suicidal twin kills sister by mistake. Dave Plowman London SW To e-mail, change noise into sound. |
#26
Posted to uk.d-i-y
|
|||
|
|||
Compulsary New Radiators
In article , Andrew
wrote: On 13/01/2021 09:55, charles wrote: In article , Owain Lastname wrote: On Wednesday, 13 January 2021 at 06:01:57 UTC, Funny Lingus wrote: Question: Does the team think that putting the heaters behind the doors would have any detrimental effect on heat distribution. All the storage heaters are under windows at the moment, so immediately lose a huge amount of heat, although double glazed. British Standard 5449 "(Central Heating) Forced circulation hot water heating systems for domestic premises" recommends: "Wherever practicable individual heat emitters (other than fan convectors) should be located on outside walls preferably beneath windows to offset the cooling effect: it is an advantage to choose an emitter of such a length that it occupies the full width of the window." My experience is that installers now prefer to put radiators on internal walls ostensibly to reduce heat loss but I think it's actually because it uses a lot less pipe. When we moved into this house' over 40 years ago, we found the radiators in the new extension were in the middle of two no-window walls. Basically, nowhere to put furniture such as bookcase or piano. I capped off one feed and extended the other to under the window. Had to do it on the surface since the room has a concrete floor. The rest of the house has suspended wooded floors. [Snip] It should have a construction slab about 5 inches thick, topped with about 80mm of aerated screed which is easier to 'polish' to give a flat surface. You can (or should have been) able to dig a channel through the screed without a massive amount of effort. and then replace the stuck down floor covering -- from KT24 in Surrey, England "I'd rather die of exhaustion than die of boredom" Thomas Carlyle |
#27
Posted to uk.d-i-y
|
|||
|
|||
Compulsary New Radiators
On 13/01/2021 13:44, Andrew wrote:
On 13/01/2021 06:01, Funny Lingus wrote: I have lived alone in a three bedroomed association house for 17 years and now there is a plan to replace all the storage heaters with a hot water system. This seems to be initiated by a government directive to make home heating more efficient by using a heat pipe. Any efficiency gain would obviously be lost by transmitting heat using water, rather than direct electricity. I am proposing that the installation of new radiators are fitted behind inward opening doors in the bedrooms and living room, this is all dead wall space and doesn't interfere with existing fitments. The upstairs landing will be housing the electric boiler and would facililitate short runs of pipework to the bedrooms, making a cleaner, more compact job. My wife, who lives in the next village has had such a conversion, but with gas as the heat source instead of electricity. This keeps breaking down and the (engineer) has to come out to fiddle with the boiler, at least a couple of dozen times now since 2019. Question: Does the team think that putting the heaters behind the doors would have any detrimental effect on heat distribution. All the storage heaters are under windows at the moment, so immediately lose a huge amount of heat, although double glazed. Best regards You should tell the housing association to spend the money on better insulation and more modern storage heaters, which is *FAR* more cost effective. Fitting a new wet radiator system, heated by electricity to an existing (not perticularly new) property could only be dreamed up by a completely clueless greenie numpty. An utterly expensive folly, only made possible by the fact that they are spending other peoples taxes. +1 Replacing the existing storage heaters with modern ones in living rooms and fitting panel radiators in bedrooms is the optimum solution and should be the cheapest to install as the circuits are already in place. |
#28
Posted to uk.d-i-y
|
|||
|
|||
Compulsary New Radiators
Andrew wrote:
As more and more coal and nuclear plants close, the availability of 'unwanted' off peak power diminishes. Indeed, which is why storage heaters aren't an obvious win in the current situation, and not necessarily a great plan for the future. I suspect the only suitable replacement in future will the OctopusAgile tarriff that gives you advance notice of what your hourly rate will be so you can plan your usage. One of the Tims seems to have this tarriff. I would be interested to know what sort of hourly rate he was paying through the recent cold snap. The Octopus website only gives historical data up to about 6 months ago. https://www.energy-stats.uk/octopus-agile/ gives 18 months worth of data. It appears the last couple of weeks have been hitting the 35p/unit price cap for several hours in the morning, as well as the evening peak. It's been about 12p during the night. Theo |
#29
Posted to uk.d-i-y
|
|||
|
|||
Compulsary New Radiators
On 13/01/2021 12:16, Dave Liquorice wrote:
On Wed, 13 Jan 2021 03:34:58 -0800 (PST), Owain Lastname wrote: If your 'electric boiler' is going to be on peak rate electricity it may be 'greener' ie use less electricity overall, but it will cost you 3x the price of storage heaters to run and 5x the price of a mains gas boiler. Or not. I pay 10.566 p/unit 24/7 on an E7 tariff. That's only about 2x mains gas. My gas is 2.3p/kWh so your E7 is 4x the price of gas -- mailto : news {at} admac {dot} myzen {dot} co {dot} uk |
#30
Posted to uk.d-i-y
|
|||
|
|||
Compulsary New Radiators
On 13/01/2021 06:01, Funny Lingus wrote:
I am proposing that the installation of new radiators are fitted behind inward opening doors in the bedrooms and living room, The radiators will probably prevent the doors opening fully. Bill |
#31
Posted to uk.d-i-y
|
|||
|
|||
Compulsary New Radiators
Funny Lingus brought next idea :
Question: Does the team think that putting the heaters behind the doors would have any detrimental effect on heat distribution. All the storage heaters are under windows at the moment, so immediately lose a huge amount of heat, although double glazed. Heat sources under windows in the conventional place to have them, because it counteracts the cold draft resulting from cooled air falling down a window. Rooms with two windows will likely have two radiators, for the same reason. Blown air heating always has the air outlets under windows. Heating is not nearly as effective, if radiators are mounted at other locations in a room. |
#32
Posted to uk.d-i-y
|
|||
|
|||
Compulsary New Radiators
On 13/01/2021 21:25, Harry Bloomfield wrote:
snip Blown air heating always has the air outlets under windows. Always? My parents' house had hot air heat, and not _one_ of the outlets/vents was under a window. They were all on inside walls, except for a couple which were set into the floor. |
#33
Posted to uk.d-i-y
|
|||
|
|||
Compulsary New Radiators
In message , S Viemeister
writes On 13/01/2021 21:25, Harry Bloomfield wrote: snip Blown air heating always has the air outlets under windows. Always? My parents' house had hot air heat, and not _one_ of the outlets/vents was under a window. They were all on inside walls, except for a couple which were set into the floor. More likely convenience of ducting from the heat source. My wife had a '60's built flat which had a central *off peak* storage bank and radiating ceiling ducts to the nearest corner of the room to be heated. When we converted to a gas boiler, the radiators were put under the windows. -- Tim Lamb |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Smart meters to be compulsary? | UK diy | |||
Smart meters to be compulsary? | UK diy | |||
Adding a new 15mm run for radiators? | UK diy | |||
Refitting floorstanding radiators on new parquet | UK diy | |||
New Boiler and Radiators | UK diy |