UK diy (uk.d-i-y) For the discussion of all topics related to diy (do-it-yourself) in the UK. All levels of experience and proficency are welcome to join in to ask questions or offer solutions.

Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 9
Default Compulsary New Radiators

I have lived alone in a three bedroomed association house for 17 years and
now there is a plan to replace all the storage heaters with a hot water
system. This seems to be initiated by a government directive to make home
heating more efficient by using a heat pipe. Any efficiency gain would
obviously be lost by transmitting heat using water, rather than direct
electricity.
I am proposing that the installation of new radiators are fitted behind
inward opening doors in the bedrooms and living room, this is all dead wall
space and doesn't interfere with existing fitments. The upstairs landing
will be housing the electric boiler and would facililitate short runs of
pipework to the bedrooms, making a cleaner, more compact job.

My wife, who lives in the next village has had such a conversion, but with
gas as the heat source instead of electricity. This keeps breaking down and
the (engineer) has to come out to fiddle with the boiler, at least a couple
of dozen times now since 2019.

Question: Does the team think that putting the heaters behind the doors
would have any detrimental effect on heat distribution. All the storage
heaters are under windows at the moment, so immediately lose a huge amount
of heat, although double glazed.

Best regards

  #2   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 2,699
Default Compulsary New Radiators

Not sure they should be compulsory, I use Storage heaters and have been
pleased with them except for the clunky mechanical louvers getting stuck
occasionally.

I thought the whole idea was eventually to use a reversible heat pump and
then it could be more efficient.
Brian

--

This newsgroup posting comes to you directly from...
The Sofa of Brian Gaff...

Blind user, so no pictures please
Note this Signature is meaningless.!
"Funny Lingus" wrote in message
...
I have lived alone in a three bedroomed association house for 17 years and
now there is a plan to replace all the storage heaters with a hot water
system. This seems to be initiated by a government directive to make home
heating more efficient by using a heat pipe. Any efficiency gain would
obviously be lost by transmitting heat using water, rather than direct
electricity.
I am proposing that the installation of new radiators are fitted behind
inward opening doors in the bedrooms and living room, this is all dead
wall space and doesn't interfere with existing fitments. The upstairs
landing will be housing the electric boiler and would facililitate short
runs of pipework to the bedrooms, making a cleaner, more compact job.

My wife, who lives in the next village has had such a conversion, but with
gas as the heat source instead of electricity. This keeps breaking down
and the (engineer) has to come out to fiddle with the boiler, at least a
couple of dozen times now since 2019.

Question: Does the team think that putting the heaters behind the doors
would have any detrimental effect on heat distribution. All the storage
heaters are under windows at the moment, so immediately lose a huge amount
of heat, although double glazed.

Best regards



  #3   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 5,774
Default Compulsary New Radiators

On 13/01/2021 06:01, Funny Lingus wrote:
I have lived alone in a three bedroomed association house for 17 years
and now there is a plan to replace all the storage heaters with a hot
water system. This seems to be initiated by a government directive to
make home heating more efficient by using a heat pipe. Any efficiency
gain would obviously be lost by transmitting heat using water, rather
than direct electricity.
I am proposing that the installation of new radiators are fitted behind
inward opening doors in the bedrooms and living room, this is all dead
wall space and doesn't interfere with existing fitments. The upstairs
landing will be housing the electric boiler and would facililitate short
runs of pipework to the bedrooms, making a cleaner, more compact job.

My wife, who lives in the next village has had such a conversion, but
with gas as the heat source instead of electricity. This keeps breaking
down and the (engineer) has to come out to fiddle with the boiler, at
least a couple of dozen times now since 2019.

Question: Does the team think that putting the heaters behind the doors
would have any detrimental effect on heat distribution. All the storage
heaters are under windows at the moment, so immediately lose a huge
amount of heat, although double glazed.

Best regards


The reason for radiators under windows is that you get a cold downward
draft from the window which even in a well heated room makes your feet
feel cold and you perceive that the room is much colder than it actually
is. Putting a radiator under the window counteracts this downward cold
draft.

If the housing association is proposing air sourced heat pumps then be
prepared for much larger radiators.

--
mailto : news {at} admac {dot} myzen {dot} co {dot} uk
  #4   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 5,774
Default Compulsary New Radiators

On 13/01/2021 08:23, Brian Gaff (Sofa) wrote:
Not sure they should be compulsory, I use Storage heaters and have been
pleased with them except for the clunky mechanical louvers getting stuck
occasionally.

I thought the whole idea was eventually to use a reversible heat pump and
then it could be more efficient.
Brian


The OP suggested that a "heat pipe" was going to be installed along with
an electric boiler so I assume that maybe he was referring to a heat
pump (air sourced). He doesn't mention cost but possibly no change from
£10k.

--
mailto : news {at} admac {dot} myzen {dot} co {dot} uk
  #5   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 5,061
Default Compulsary New Radiators

In article , Owain
Lastname wrote:
On Wednesday, 13 January 2021 at 06:01:57 UTC, Funny Lingus wrote:
Question: Does the team think that putting the heaters behind the doors
would have any detrimental effect on heat distribution. All the
storage heaters are under windows at the moment, so immediately lose a
huge amount of heat, although double glazed.


British Standard 5449 "(Central Heating) Forced circulation hot water
heating systems for domestic premises" recommends: "Wherever practicable
individual heat emitters (other than fan convectors) should be located on
outside walls preferably beneath windows to offset the cooling effect: it
is an advantage to choose an emitter of such a length that it occupies
the full width of the window."


My experience is that installers now prefer to put radiators on internal
walls ostensibly to reduce heat loss but I think it's actually because it
uses a lot less pipe.


When we moved into this house' over 40 years ago, we found the radiators
in the new extension were in the middle of two no-window walls. Basically,
nowhere to put furniture such as bookcase or piano. I capped off one feed
and extended the other to under the window. Had to do it on the surface
since the room has a concrete floor. The rest of the house has suspended
wooded floors. [Snip]

--
from KT24 in Surrey, England
"I'd rather die of exhaustion than die of boredom" Thomas Carlyle


  #6   Report Post  
Posted to uk.d-i-y
jon jon is offline
external usenet poster
 
Posts: 434
Default Compulsary New Radiators

On Wed, 13 Jan 2021 01:07:07 -0800, Owain Lastname wrote:

On Wednesday, 13 January 2021 at 06:01:57 UTC, Funny Lingus wrote:
Question: Does the team think that putting the heaters behind the doors
would have any detrimental effect on heat distribution. All the storage
heaters are under windows at the moment, so immediately lose a huge
amount of heat, although double glazed.


British Standard 5449 "(Central Heating) Forced circulation hot water
heating systems for domestic premises" recommends: "Wherever practicable
individual heat emitters (other than fan convectors) should be located
on outside walls preferably beneath windows to offset the cooling
effect: it is an advantage to choose an emitter of such a length that it
occupies the full width of the window."

My experience is that installers now prefer to put radiators on internal
walls ostensibly to reduce heat loss but I think it's actually because
it uses a lot less pipe. They also like radiators back-to-back on the
same wall for the same reason.

A housing association job in an occupied property will try to be the
quickest, easiest, (cheapest) least disruptive job possible.

Storage heaters shouldn't be on external walls because of their far
greater heat loss to the back of the heater.

In larger rooms I would push for two radiators where possible.

I had a grant-assisted heating system put in last year and the
installers hated me. They wanted a quick easy cheap install with pipes
going across the hall ceiling, only to find that all my cornicing has
cabling inside it. (Concrete floor and ceiling in a flat.) So they ended
up with long 22mm pipe runs round the entire perimeter of the building.
I regard this as useful background heat even if the radiators are off.

Also watch them installing them because they seem to default to minmum
spacing off the wall to look "neater". I made tnem turn the wall
brackets round to space radiators further off the external walls.

Overall the job wasn't what I'd have wanted if I was paying for it all
myself but a new gas supply, boiler and 6 rads for £1100 all in was a
bargain.

Owain


Thanks Owain, useful info there in your note.
  #7   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 132
Default Compulsary New Radiators

On 13/01/2021 08:55, alan_m wrote:

The reason for radiators under windows is that you get a cold downward
draft from the window which even in a well heated room makes your feet
feel cold and you perceive that the room is much colder than it actually
is. Putting a radiator under the window counteracts this downward cold
draft.


The main reason is that it's generally otherwise unused space.

--
Cheers
Clive

  #8   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 2,704
Default Compulsary New Radiators

On 13/01/2021 08:55, alan_m wrote:
On 13/01/2021 06:01, Funny Lingus wrote:
I have lived alone in a three bedroomed association house for 17 years
and now there is a plan to replace all the storage heaters with a hot
water system. This seems to be initiated by a government directive to
make home heating more efficient by using a heat pipe. Any efficiency
gain would obviously be lost by transmitting heat using water, rather
than direct electricity.
I am proposing that the installation of new radiators are fitted
behind inward opening doors in the bedrooms and living room, this is
all dead wall space and doesn't interfere with existing fitments. The
upstairs landing will be housing the electric boiler and would
facililitate short runs of pipework to the bedrooms, making a cleaner,
more compact job.

My wife, who lives in the next village has had such a conversion, but
with gas as the heat source instead of electricity. This keeps
breaking down and the (engineer) has to come out to fiddle with the
boiler, at least a couple of dozen times now since 2019.

Question: Does the team think that putting the heaters behind the
doors would have any detrimental effect on heat distribution. All the
storage heaters are under windows at the moment, so immediately lose a
huge amount of heat, although double glazed.


The reason for radiators under windows is that you get a cold downward
draft from the window which even in a well heated room makes your feet
feel cold and you perceive that the room is much colder than it actually
is. Putting a radiator under the window counteracts this downward cold
draft.


I think that's much less important with double glazing and better wall
insulation as there won't be such a temperature gradient across the room.

--
Max Demian
  #9   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 478
Default Compulsary New Radiators

On 13/01/2021 06:01, Funny Lingus wrote:
I have lived alone in a three bedroomed association house for 17 years
and now there is a plan to replace all the storage heaters with a hot
water system. This seems to be initiated by a government directive to
make home heating more efficient by using a heat pipe. Any efficiency
gain would obviously be lost by transmitting heat using water, rather
than direct electricity.


The main problem with this scheme is that turning electricity into heat
in a resistor is an incredibly *wasteful* way to do it. Heat pump is a
much better approach (although they have maintenance issues too much
more so than a gas or oil boiler).

The "green" initiative to make all heating electric is conceptually
flawed. We barely have enough electricity generating capacity as it is.
Turning high grade electricity directly into low grade thermal heat is
about the dumbest possible way of doing it. Any other means is
preferable in terms of overall end to end energy efficiency.

Add in a few more electric cars and we will be tipped over the edge -
particularly in winter when it is cloudy and the wind isn't blowing!

I am proposing that the installation of new radiators are fitted behind
inward opening doors in the bedrooms and living room, this is all dead
wall space and doesn't interfere with existing fitments. The upstairs
landing will be housing the electric boiler and would facililitate short
runs of pipework to the bedrooms, making a cleaner, more compact job.


Modern approach would be to put radiators on internal walls so that any
heat going through the wall stays in the house. Old style they tended to
put them under the windows to mask cold drafts coming down off the
windows. Decent double makes quite a difference here.

My wife, who lives in the next village has had such a conversion, but
with gas as the heat source instead of electricity. This keeps breaking
down and the (engineer) has to come out to fiddle with the boiler, at
least a couple of dozen times now since 2019.


There is no reason why a correctly installed gas boiler should break
down so often. They need one annual maintenance if you play by the book
but I know plenty of people who never seem to bother. Likewise for oil
fired although that can be a bit tetchy if you get a gale with the wind
in the wrong direction.

Question: Does the team think that putting the heaters behind the doors
would have any detrimental effect on heat distribution. All the storage
heaters are under windows at the moment, so immediately lose a huge
amount of heat, although double glazed.


You will notice some cold drafts coming down from the windows and making
the floor level colder. That was the old rationale for putting radiators
in front of the windows. The aluminium faced polystyrene foam sheets
placed behind the radiators prevent losses through the wall very well.

--
Regards,
Martin Brown
  #10   Report Post  
Posted to uk.d-i-y
jon jon is offline
external usenet poster
 
Posts: 434
Default Compulsary New Radiators

On Wed, 13 Jan 2021 10:31:41 +0000, Martin Brown wrote:

On 13/01/2021 06:01, Funny Lingus wrote:
I have lived alone in a three bedroomed association house for 17 years
and now there is a plan to replace all the storage heaters with a hot
water system. This seems to be initiated by a government directive to
make home heating more efficient by using a heat pipe. Any efficiency
gain would obviously be lost by transmitting heat using water, rather
than direct electricity.


The main problem with this scheme is that turning electricity into heat
in a resistor is an incredibly *wasteful* way to do it. Heat pump is a
much better approach (although they have maintenance issues too much
more so than a gas or oil boiler).

The "green" initiative to make all heating electric is conceptually
flawed. We barely have enough electricity generating capacity as it is.
Turning high grade electricity directly into low grade thermal heat is
about the dumbest possible way of doing it. Any other means is
preferable in terms of overall end to end energy efficiency.

Add in a few more electric cars and we will be tipped over the edge -
particularly in winter when it is cloudy and the wind isn't blowing!

I am proposing that the installation of new radiators are fitted behind
inward opening doors in the bedrooms and living room, this is all dead
wall space and doesn't interfere with existing fitments. The upstairs
landing will be housing the electric boiler and would facililitate
short runs of pipework to the bedrooms, making a cleaner, more compact
job.


Modern approach would be to put radiators on internal walls so that any
heat going through the wall stays in the house. Old style they tended to
put them under the windows to mask cold drafts coming down off the
windows. Decent double makes quite a difference here.

My wife, who lives in the next village has had such a conversion, but
with gas as the heat source instead of electricity. This keeps breaking
down and the (engineer) has to come out to fiddle with the boiler, at
least a couple of dozen times now since 2019.


There is no reason why a correctly installed gas boiler should break
down so often. They need one annual maintenance if you play by the book
but I know plenty of people who never seem to bother. Likewise for oil
fired although that can be a bit tetchy if you get a gale with the wind
in the wrong direction.

Question: Does the team think that putting the heaters behind the doors
would have any detrimental effect on heat distribution. All the storage
heaters are under windows at the moment, so immediately lose a huge
amount of heat, although double glazed.


You will notice some cold drafts coming down from the windows and making
the floor level colder. That was the old rationale for putting radiators
in front of the windows. The aluminium faced polystyrene foam sheets
placed behind the radiators prevent losses through the wall very well.


I think a very high capacity Lithium battery would add to the cost/
effectiveness so it could be charged off peak and the main storage
radiator turned on later in the day.


  #11   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 478
Default Compulsary New Radiators

On 13/01/2021 10:58, jon wrote:

I think a very high capacity Lithium battery would add to the cost/
effectiveness so it could be charged off peak and the main storage
radiator turned on later in the day.


It would also more than double the installation costs and in all
probability have a working life in regular use of at most a decade.

https://www.bbc.co.uk/news/technology-55337192

Thermal store is the least bad option if you must do it this way.

UK's big problem right now is not enough electricity generating capacity
in winter going forwards. It will only take a calm blocking high and the
most of Europe becalmed and we will be having electricity rationing.

Solar is pathetic on grey winters days with the sun barely above the
horizon even if the clouds do part for an hour or so.

--
Regards,
Martin Brown
  #12   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 870
Default Compulsary New Radiators

alan_m wrote:
On 13/01/2021 08:23, Brian Gaff (Sofa) wrote:
Not sure they should be compulsory, I use Storage heaters and have been
pleased with them except for the clunky mechanical louvers getting stuck
occasionally.

I thought the whole idea was eventually to use a reversible heat pump and
then it could be more efficient.
Brian


The OP suggested that a "heat pipe" was going to be installed along with
an electric boiler so I assume that maybe he was referring to a heat
pump (air sourced). He doesn't mention cost but possibly no change from
£10k.


Heat pipes are amazing. They use phase change (vapor changing back
to fluid, releasing the heat of vaporization) as a transport mechanism.
Some hobbyist computers have heatpipes in the CPU heatsink, and
the transport mechanism is so powerful, it has better thermal
conduction properties than an equivalent diameter of solid copper.
That's because it is an active transport, whereas solid copper
is merely a passive transport.

https://en.wikipedia.org/wiki/Heat_pipe

Heatpipes don't have to be expensive to work.

They can also "work uphill", if the inside surface of
the plumbing is "sintered" and the capillary action
that results, allows condensed fluid to travel uphill.
A more preferred situation, is for the condensed fluid
to flow downhill back to the heat source (storage heater).

You could do this:

In the diagram, the working fluid in the storage heater (water),
does not mix with the working fluid in the heatpipe (pure alcohol).
The entire heatpipe only has a few teaspoons of alcohol. It does
not have, nor need, gallons of alcohol. The transport is vapor
phase, and little vapor is needed.

+-+
| +== Radiator
+-------------+ heat pipe | +==
| |+------------------------+ +==
| Storage || +-----------------------+
| heater || | (hollow) condenses
| |+--+
+-------------+ Makes
alcohol [Vapor phase transport]
vapor

The benefit is, you don't need the storage tank in the upstairs room.

Now, the problem with placing a heatpump on the left hand
side of that picture, is the need for winter heating and
summer cooling, to work with the same gubbins. In principle,
I think you could make it work. But... it might not have
the degree of efficiency desired. If I only had to set it
up for one season (only for winter heating), I could
make it work slightly better.

Just as the general discussion of heatpumps leaves me cold.
Heatpumps are a low quality heat source, requiring extraordinary
efforts to transfer the heat into a room. Adding a heatpipe
to the picture, is just additional aggravation, making
a "marginal situation", "more marginal". Stupid even.

The electric storage heater, the electric part is
"high quality" heat. When you couple it with the
storage part, that degrades the quality a bit. If the
water cools down to 40C, what do you do with the
remaining heat ? That's not a high enough temp
to really heat the room any more.

Heatpipes have a design power limit. For example, if
you put more than 200W into the CPU heatsink, all
of the working fluid in the pipes remains in the
vapor phase, and the nice thermal pumping action
stops. The idea then, is to ensure the heatpipe is
big enough, for the application, so it doesn't "saturate".

Heatpipes have apparently already been used in
air-to-air heat exchangers for R2000 homes. But I
haven't seen any pictures of working units of that type,
so I don't know what the implementation looks like.

Paul
  #13   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 1,264
Default Compulsary New Radiators

Funny Lingus wrote:
I have lived alone in a three bedroomed association house for 17 years and
now there is a plan to replace all the storage heaters with a hot water
system. This seems to be initiated by a government directive to make home
heating more efficient by using a heat pipe. Any efficiency gain would
obviously be lost by transmitting heat using water, rather than direct
electricity.


Do you have mains gas?

What is the state of your insulation?
- cavity walls? insulated?
- loft insulation? How thick?
- double glazing?
- draught proofing?
- air bricks?

ASHP can be 2-4x as efficient as pure electric heat so, while there are
losses in a wet system, they are likely to be overridden by the heat pump
efficiency. On the other hand, if your house is poorly insulated the heat
pump may not be able to keep up (unless you fit a huge one, which is
costly).

(ASHP can struggle in freezing weather, but it's hard not to beat pure
electric heat)

I am proposing that the installation of new radiators are fitted behind
inward opening doors in the bedrooms and living room, this is all dead wall
space and doesn't interfere with existing fitments. The upstairs landing
will be housing the electric boiler and would facililitate short runs of
pipework to the bedrooms, making a cleaner, more compact job.


It depends on the heating system as to the flow temperature. I'd expect
that putting a radiator behind a door is going to be less effective if you
leave the door open most of the time. Obviously it'll put heat into the
room eventually (nowhere else for it to go), but spend a while heating up
the door first.

My wife, who lives in the next village has had such a conversion, but with
gas as the heat source instead of electricity. This keeps breaking down and
the (engineer) has to come out to fiddle with the boiler, at least a couple
of dozen times now since 2019.


That sounds like a regular wet system with a gas boiler, as used by millions
of people. They don't keep breaking down, which suggests some problem with
the (quality of the) installation. Was that fitted by the same HA?

Theo
  #14   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 14,085
Default Compulsary New Radiators

On Wed, 13 Jan 2021 10:30:02 +0000, Max Demian wrote:

Question: Does the team think that putting the heaters behind the


doors would have any detrimental effect on heat distribution. All

the
storage heaters are under windows at the moment, so immediately

lose a
huge amount of heat, although double glazed.


The reason for radiators under windows is that you get a cold

downward
draft from the window which even in a well heated room makes your

feet
feel cold and you perceive that the room is much colder than it
actually. Putting a radiator under the window counteracts this

downward
cold draft.


I think that's much less important with double glazing and better wall
insulation as there won't be such a temperature gradient across the
room.


It's not so much a temperature gradient across the room as air
ciculation. The windows, double or single glazed, will cool the air
this becomes more dense and sinks drawing warmer air down. This sets
up a circulation, the bottomm line being your feet are in a cold
draft.

Decent curtains outside the window reveal and tucked behind the top
of the radiator keep the warm air in and any circulation within the
reveal. Even better if you can fit another set of curtains adjacent
to the windows.

Behind doors strikes me as a really bad place for a radiator.
Are doors habitually left open or closed? Open is going to restrict
how much heat the raditor can effectively transfer to the room.

Will there be enough space for a radiator to fit without fouling the
door when it is open?.

Doors tend to be opposite windows, this will enhance the circulation
due to the window cooling effect.

--
Cheers
Dave.



  #15   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 14,085
Default Compulsary New Radiators

On Wed, 13 Jan 2021 06:01:52 -0000, Funny Lingus wrote:

... now there is a plan to replace all the storage heaters with a hot
water system. This seems to be initiated by a government directive to
make home heating more efficient by using a heat pipe.


What do you mean by "heat pipe"? Do you mean some form of heat pump
or a massive central communal boiler feeding hot water to individual
properties?

Any efficiency gain would obviously be lost by transmitting heat using
water, rather than direct electricity.


Old, and at 17 years, yours are "old", storeage heaters aren't
particulary good, they leak to much heat during the day and can't
cope with a sudden cold snap.

A wet system heated by electricity as a replacement does seem a bit
cock eyed. Though remember any "lost" heat from the pipework/boiler
is still within the property.

The upstairs landing will be housing the electric boiler and would
facililitate short runs of pipework to the bedrooms, making a cleaner,
more compact job.


Is that a boiler just for domestic hatowater or a heating boiler?
Space heating requires a lot of power, you have storeage heaters
already so your (E7?) supply should be up to it. But you'll need a
preety large tank of water to store enough heat to heat the place
sensibly through the day. Unless the system forces you to use
electricity through the day for space heating. That is likely to be
expensive(*).

I'd have thought that just replacing the old storeage heaters with
modern "high heat rention" ones would be a far better option. They
aren't cheap though, I suspect the proposed wet system would be
cheaper...

(*) Depending on your E7 tarrif. Just switched our E7 to one that
charges the same per unit day or night. The bill will go up but only
inline with normal increases. The night unit price has gone up and
the day unit down. I'm paying less per unit on the E7 supply than I
am for the ordinary supply. 10.566 p/unit v 14.024 p/unit (+ 5% VAT).

--
Cheers
Dave.





  #16   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 14,085
Default Compulsary New Radiators

On Wed, 13 Jan 2021 03:34:58 -0800 (PST), Owain Lastname wrote:

If your 'electric boiler' is going to be on peak rate electricity it may be 'greener' ie use less electricity overall, but it will cost you 3x
the price of storage heaters to run and 5x the price of a mains gas
boiler.


Or not. I pay 10.566 p/unit 24/7 on an E7 tariff. That's only about
2x mains gas.

Some housing associations (or their tenants) have been bitten badly by
ill-advised 'eco' heating schemes that are lucrative for the scheme
developers.


+1

What the OP has posted sets off that alarm bell with me as well.

--
Cheers
Dave.



  #17   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 1
Default Compulsary New Radiators

On Wed, 13 Jan 2021 11:36:56 +0000, Theo wrote:

Funny Lingus wrote:
I have lived alone in a three bedroomed association house for 17 years
and now there is a plan to replace all the storage heaters with a hot
water system. This seems to be initiated by a government directive to
make home heating more efficient by using a heat pipe. Any efficiency
gain would obviously be lost by transmitting heat using water, rather
than direct electricity.


Do you have mains gas? No mains gas in village

What is the state of your insulation?
- cavity walls? insulated? yes
- loft insulation? How thick? 12"
- double glazing? yes
- draught proofing? some internal doors
- air bricks? Bathroom and kitchen

ASHP can be 2-4x as efficient as pure electric heat so, while there are
losses in a wet system, they are likely to be overridden by the heat
pump efficiency. On the other hand, if your house is poorly insulated
the heat pump may not be able to keep up (unless you fit a huge one,
which is costly).

(ASHP can struggle in freezing weather, but it's hard not to beat pure
electric heat)

I am proposing that the installation of new radiators are fitted behind
inward opening doors in the bedrooms and living room, this is all dead
wall space and doesn't interfere with existing fitments. The upstairs
landing will be housing the electric boiler and would facililitate
short runs of pipework to the bedrooms, making a cleaner, more compact
job.


It depends on the heating system as to the flow temperature. I'd expect
that putting a radiator behind a door is going to be less effective if
you leave the door open most of the time. Obviously it'll put heat into
the room eventually (nowhere else for it to go), but spend a while
heating up the door first.

My wife, who lives in the next village has had such a conversion, but
with gas as the heat source instead of electricity. This keeps breaking
down and the (engineer) has to come out to fiddle with the boiler, at
least a couple of dozen times now since 2019.


That sounds like a regular wet system with a gas boiler, as used by
millions of people. They don't keep breaking down, which suggests some
problem with the (quality of the) installation. Was that fitted by the
same HA?

Theo


  #18   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 6,213
Default Compulsary New Radiators

On 13/01/2021 06:01, Funny Lingus wrote:
I have lived alone in a three bedroomed association house for 17 years
and now there is a plan to replace all the storage heaters with a hot
water system. This seems to be initiated by a government directive to
make home heating more efficient by using a heat pipe. Any efficiency
gain would obviously be lost by transmitting heat using water, rather
than direct electricity.
I am proposing that the installation of new radiators are fitted behind
inward opening doors in the bedrooms and living room, this is all dead
wall space and doesn't interfere with existing fitments. The upstairs
landing will be housing the electric boiler and would facililitate short
runs of pipework to the bedrooms, making a cleaner, more compact job.

My wife, who lives in the next village has had such a conversion, but
with gas as the heat source instead of electricity. This keeps breaking
down and the (engineer) has to come out to fiddle with the boiler, at
least a couple of dozen times now since 2019.

Question: Does the team think that putting the heaters behind the doors
would have any detrimental effect on heat distribution. All the storage
heaters are under windows at the moment, so immediately lose a huge
amount of heat, although double glazed.

Best regards


You should tell the housing association to spend the money on better
insulation and more modern storage heaters, which is *FAR* more cost
effective.

Fitting a new wet radiator system, heated by electricity to an existing
(not perticularly new) property could only be dreamed up by a
completely clueless greenie numpty. An utterly expensive folly, only
made possible by the fact that they are spending other peoples taxes.


  #19   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 6,213
Default Compulsary New Radiators

On 13/01/2021 09:55, charles wrote:
In article , Owain
Lastname wrote:
On Wednesday, 13 January 2021 at 06:01:57 UTC, Funny Lingus wrote:
Question: Does the team think that putting the heaters behind the doors
would have any detrimental effect on heat distribution. All the
storage heaters are under windows at the moment, so immediately lose a
huge amount of heat, although double glazed.


British Standard 5449 "(Central Heating) Forced circulation hot water
heating systems for domestic premises" recommends: "Wherever practicable
individual heat emitters (other than fan convectors) should be located on
outside walls preferably beneath windows to offset the cooling effect: it
is an advantage to choose an emitter of such a length that it occupies
the full width of the window."


My experience is that installers now prefer to put radiators on internal
walls ostensibly to reduce heat loss but I think it's actually because it
uses a lot less pipe.


When we moved into this house' over 40 years ago, we found the radiators
in the new extension were in the middle of two no-window walls. Basically,
nowhere to put furniture such as bookcase or piano. I capped off one feed
and extended the other to under the window. Had to do it on the surface
since the room has a concrete floor. The rest of the house has suspended
wooded floors. [Snip]


It should have a construction slab about 5 inches thick, topped with
about 80mm of aerated screed which is easier to 'polish' to give a
flat surface. You can (or should have been) able to dig a channel
through the screed without a massive amount of effort.


  #20   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 6,213
Default Compulsary New Radiators

On 13/01/2021 10:04, jon wrote:
On Wed, 13 Jan 2021 01:07:07 -0800, Owain Lastname wrote:

On Wednesday, 13 January 2021 at 06:01:57 UTC, Funny Lingus wrote:
Question: Does the team think that putting the heaters behind the doors
would have any detrimental effect on heat distribution. All the storage
heaters are under windows at the moment, so immediately lose a huge
amount of heat, although double glazed.


British Standard 5449 "(Central Heating) Forced circulation hot water
heating systems for domestic premises" recommends: "Wherever practicable
individual heat emitters (other than fan convectors) should be located
on outside walls preferably beneath windows to offset the cooling
effect: it is an advantage to choose an emitter of such a length that it
occupies the full width of the window."

My experience is that installers now prefer to put radiators on internal
walls ostensibly to reduce heat loss but I think it's actually because
it uses a lot less pipe. They also like radiators back-to-back on the
same wall for the same reason.

A housing association job in an occupied property will try to be the
quickest, easiest, (cheapest) least disruptive job possible.

Storage heaters shouldn't be on external walls because of their far
greater heat loss to the back of the heater.

In larger rooms I would push for two radiators where possible.

I had a grant-assisted heating system put in last year and the
installers hated me. They wanted a quick easy cheap install with pipes
going across the hall ceiling, only to find that all my cornicing has
cabling inside it. (Concrete floor and ceiling in a flat.) So they ended
up with long 22mm pipe runs round the entire perimeter of the building.
I regard this as useful background heat even if the radiators are off.

Also watch them installing them because they seem to default to minmum
spacing off the wall to look "neater". I made tnem turn the wall
brackets round to space radiators further off the external walls.

Overall the job wasn't what I'd have wanted if I was paying for it all
myself but a new gas supply, boiler and 6 rads for £1100 all in was a
bargain.

Owain


Thanks Owain, useful info there in your note.


I don't believe it is possible to have gas installed, and entire
boiler+rads+controls+pipes for £1100. £11,000 very possibly and
half of that for providing gas to the property.


  #21   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 6,213
Default Compulsary New Radiators

On 13/01/2021 12:16, Dave Liquorice wrote:
On Wed, 13 Jan 2021 03:34:58 -0800 (PST), Owain Lastname wrote:

If your 'electric boiler' is going to be on peak rate electricity it may be 'greener' ie use less electricity overall, but it will cost you 3x
the price of storage heaters to run and 5x the price of a mains gas
boiler.


Or not. I pay 10.566 p/unit 24/7 on an E7 tariff. That's only about
2x mains gas.

As more and more coal and nuclear plants close, the availability of
'unwanted' off peak power diminishes.

I suspect the only suitable replacement in future will the
OctopusAgile tarriff that gives you advance notice of what your
hourly rate will be so you can plan your usage.

One of the Tims seems to have this tarriff. I would be interested
to know what sort of hourly rate he was paying through the recent
cold snap. The Octopus website only gives historical data up to
about 6 months ago.

Some housing associations (or their tenants) have been bitten badly by
ill-advised 'eco' heating schemes that are lucrative for the scheme
developers.


+1

What the OP has posted sets off that alarm bell with me as well.

++1
  #22   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 6,213
Default Compulsary New Radiators

On 13/01/2021 11:36, Theo wrote:
Funny Lingus wrote:
I have lived alone in a three bedroomed association house for 17 years and
now there is a plan to replace all the storage heaters with a hot water
system. This seems to be initiated by a government directive to make home
heating more efficient by using a heat pipe. Any efficiency gain would
obviously be lost by transmitting heat using water, rather than direct
electricity.


Do you have mains gas?

What is the state of your insulation?
- cavity walls? insulated?
- loft insulation? How thick?
- double glazing?
- draught proofing?
- air bricks?

ASHP can be 2-4x as efficient as pure electric heat so, while there are
losses in a wet system, they are likely to be overridden by the heat pump
efficiency. On the other hand, if your house is poorly insulated the heat
pump may not be able to keep up (unless you fit a huge one, which is
costly).

(ASHP can struggle in freezing weather, but it's hard not to beat pure
electric heat)

I am proposing that the installation of new radiators are fitted behind
inward opening doors in the bedrooms and living room, this is all dead wall
space and doesn't interfere with existing fitments. The upstairs landing
will be housing the electric boiler and would facililitate short runs of
pipework to the bedrooms, making a cleaner, more compact job.


It depends on the heating system as to the flow temperature. I'd expect
that putting a radiator behind a door is going to be less effective if you
leave the door open most of the time. Obviously it'll put heat into the
room eventually (nowhere else for it to go), but spend a while heating up
the door first.

My wife, who lives in the next village has had such a conversion, but with
gas as the heat source instead of electricity. This keeps breaking down and
the (engineer) has to come out to fiddle with the boiler, at least a couple
of dozen times now since 2019.


That sounds like a regular wet system with a gas boiler, as used by millions
of people. They don't keep breaking down, which suggests some problem with
the (quality of the) installation. Was that fitted by the same HA?

Theo

Does someone in the HA get kickbacks from the installer who quoted
far more than he would get away with where a private customer is
concerned ?
  #23   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 6,213
Default Compulsary New Radiators

On 13/01/2021 12:11, Dave Liquorice wrote:

(*) Depending on your E7 tarrif. Just switched our E7 to one that
charges the same per unit day or night. The bill will go up but only
inline with normal increases. The night unit price has gone up and
the day unit down. I'm paying less per unit on the E7 supply than I
am for the ordinary supply. 10.566 p/unit v 14.024 p/unit (+ 5% VAT).


Which company/tariff ?
  #25   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 43,017
Default Compulsary New Radiators

In article ,
alan_m wrote:
The reason for radiators under windows is that you get a cold downward
draft from the window which even in a well heated room makes your feet
feel cold and you perceive that the room is much colder than it actually
is. Putting a radiator under the window counteracts this downward cold
draft.


I was told it aids circulation in the room, evening up the temperature.
Although suspect it was just a convenient place to put it in many rooms.

--
*Suicidal twin kills sister by mistake.

Dave Plowman London SW
To e-mail, change noise into sound.


  #26   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 5,061
Default Compulsary New Radiators

In article , Andrew
wrote:
On 13/01/2021 09:55, charles wrote:
In article ,
Owain Lastname wrote:
On Wednesday, 13 January 2021 at 06:01:57 UTC, Funny Lingus wrote:
Question: Does the team think that putting the heaters behind the
doors would have any detrimental effect on heat distribution. All the
storage heaters are under windows at the moment, so immediately lose
a huge amount of heat, although double glazed.


British Standard 5449 "(Central Heating) Forced circulation hot water
heating systems for domestic premises" recommends: "Wherever
practicable individual heat emitters (other than fan convectors)
should be located on outside walls preferably beneath windows to
offset the cooling effect: it is an advantage to choose an emitter of
such a length that it occupies the full width of the window."


My experience is that installers now prefer to put radiators on
internal walls ostensibly to reduce heat loss but I think it's
actually because it uses a lot less pipe.


When we moved into this house' over 40 years ago, we found the
radiators in the new extension were in the middle of two no-window
walls. Basically, nowhere to put furniture such as bookcase or piano. I
capped off one feed and extended the other to under the window. Had to
do it on the surface since the room has a concrete floor. The rest of
the house has suspended wooded floors. [Snip]


It should have a construction slab about 5 inches thick, topped with
about 80mm of aerated screed which is easier to 'polish' to give a flat
surface. You can (or should have been) able to dig a channel through the
screed without a massive amount of effort.


and then replace the stuck down floor covering

--
from KT24 in Surrey, England
"I'd rather die of exhaustion than die of boredom" Thomas Carlyle
  #27   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 117
Default Compulsary New Radiators

On 13/01/2021 13:44, Andrew wrote:
On 13/01/2021 06:01, Funny Lingus wrote:
I have lived alone in a three bedroomed association house for 17 years
and now there is a plan to replace all the storage heaters with a hot
water system. This seems to be initiated by a government directive to
make home heating more efficient by using a heat pipe. Any efficiency
gain would obviously be lost by transmitting heat using water, rather
than direct electricity.
I am proposing that the installation of new radiators are fitted
behind inward opening doors in the bedrooms and living room, this is
all dead wall space and doesn't interfere with existing fitments. The
upstairs landing will be housing the electric boiler and would
facililitate short runs of pipework to the bedrooms, making a cleaner,
more compact job.

My wife, who lives in the next village has had such a conversion, but
with gas as the heat source instead of electricity. This keeps
breaking down and the (engineer) has to come out to fiddle with the
boiler, at least a couple of dozen times now since 2019.

Question: Does the team think that putting the heaters behind the
doors would have any detrimental effect on heat distribution. All the
storage heaters are under windows at the moment, so immediately lose a
huge amount of heat, although double glazed.

Best regards


You should tell the housing association to spend the money on better
insulation and more modern storage heaters, which is *FAR* more cost
effective.

Fitting a new wet radiator system, heated by electricity to an existing
(not perticularly new) property could only be dreamed up by a
completely clueless greenie numpty. An utterly expensive folly, only
made possible by the fact that they are spending other peoples taxes.


+1

Replacing the existing storage heaters with modern ones in living rooms
and fitting panel radiators in bedrooms is the optimum solution and
should be the cheapest to install as the circuits are already in place.
  #28   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 1,264
Default Compulsary New Radiators

Andrew wrote:
As more and more coal and nuclear plants close, the availability of
'unwanted' off peak power diminishes.


Indeed, which is why storage heaters aren't an obvious win in the current
situation, and not necessarily a great plan for the future.

I suspect the only suitable replacement in future will the
OctopusAgile tarriff that gives you advance notice of what your
hourly rate will be so you can plan your usage.

One of the Tims seems to have this tarriff. I would be interested
to know what sort of hourly rate he was paying through the recent
cold snap. The Octopus website only gives historical data up to
about 6 months ago.


https://www.energy-stats.uk/octopus-agile/
gives 18 months worth of data.

It appears the last couple of weeks have been hitting the 35p/unit price
cap for several hours in the morning, as well as the evening peak. It's
been about 12p during the night.

Theo
  #29   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 5,774
Default Compulsary New Radiators

On 13/01/2021 12:16, Dave Liquorice wrote:
On Wed, 13 Jan 2021 03:34:58 -0800 (PST), Owain Lastname wrote:

If your 'electric boiler' is going to be on peak rate electricity it may be 'greener' ie use less electricity overall, but it will cost you 3x
the price of storage heaters to run and 5x the price of a mains gas
boiler.


Or not. I pay 10.566 p/unit 24/7 on an E7 tariff. That's only about
2x mains gas.


My gas is 2.3p/kWh so your E7 is 4x the price of gas




--
mailto : news {at} admac {dot} myzen {dot} co {dot} uk
  #30   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 1,159
Default Compulsary New Radiators

On 13/01/2021 06:01, Funny Lingus wrote:

I am proposing that the installation of new radiators are fitted behind
inward opening doors in the bedrooms and living room,


The radiators will probably prevent the doors opening fully.

Bill


  #31   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 875
Default Compulsary New Radiators

Funny Lingus brought next idea :
Question: Does the team think that putting the heaters behind the doors would
have any detrimental effect on heat distribution. All the storage heaters are
under windows at the moment, so immediately lose a huge amount of heat,
although double glazed.


Heat sources under windows in the conventional place to have them,
because it counteracts the cold draft resulting from cooled air falling
down a window. Rooms with two windows will likely have two radiators,
for the same reason. Blown air heating always has the air outlets under
windows.

Heating is not nearly as effective, if radiators are mounted at other
locations in a room.
  #32   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 1,655
Default Compulsary New Radiators

On 13/01/2021 21:25, Harry Bloomfield wrote:
snip
Blown air heating always has the air outlets under
windows.

Always? My parents' house had hot air heat, and not _one_ of the
outlets/vents was under a window. They were all on inside walls, except
for a couple which were set into the floor.
  #33   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 6,938
Default Compulsary New Radiators

In message , S Viemeister
writes
On 13/01/2021 21:25, Harry Bloomfield wrote:
snip
Blown air heating always has the air outlets under windows.

Always? My parents' house had hot air heat, and not _one_ of the
outlets/vents was under a window. They were all on inside walls, except
for a couple which were set into the floor.


More likely convenience of ducting from the heat source. My wife had a
'60's built flat which had a central *off peak* storage bank and
radiating ceiling ducts to the nearest corner of the room to be heated.
When we converted to a gas boiler, the radiators were put under the
windows.

--
Tim Lamb
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Smart meters to be compulsary? harry UK diy 75 November 21st 19 09:44 PM
Smart meters to be compulsary? Dave Plowman (News) UK diy 17 November 3rd 19 06:36 PM
Adding a new 15mm run for radiators? htmark98 UK diy 18 December 29th 05 11:32 PM
Refitting floorstanding radiators on new parquet OK UK diy 4 September 29th 05 10:53 AM
New Boiler and Radiators SidKnee UK diy 0 March 7th 05 10:33 PM


All times are GMT +1. The time now is 04:02 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"