Default Securing a CU to a wall

I have been trying to wire in the last few circuits into my previously installed CU and have been having problems with the fixings.
From previous posts you may recall that barring three cables coming down the wall the rest come from beneath the floor in trunking beside the CU, and all cables enter the CU from behind. To facilitate this the CU is on stand-offs and it is these that I underestimated and have been trying to insert larger ones to accommodate the additional cables. The issue that has developed is that the wall is made of cinder "breeze" blocks and the metal wall plugs have worked themselves loose. Unfortunately the CU cannot be re-sited owing to being surrounded by meters , cutout and isolator switch further restricted by having to fit under a worktop. So what are my options?

One option is to embed studding into wall securing it with epoxy or car body filler. Are these fire rated?

Second option is to fit a ply or chipboard back board feeding the cables behind with holes to match the cable entry holes. Advantage of this is that it gives me options to find sound fixing points in the wall and screwing the CU to the board. it would alleviate some of the issue of having to feed the cables into the CU before securing to the wall as it is the weight of the cables that causes the above issues of pulling out the plugs before the CU can be firmly secured. I have seen plenty of CUs attached this way inside exterior service boxes. Would this now meet current fire ratings?

Option three having seen CUs mounted on drywalling I presume PB is regarded as adequate fire rated. I could cover the board in option 2?

The plan was/is to seal all gaps and openings with fire rated foam to ensure the integrity of the CU.

I would be grateful for any opinions on my proposals or any alternatives. Currently the CU has only wired with the original circuits and is precariously hanging off two not so secure screws, so no pressure

Richard
 
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
securing to plasterboard wall TheScullster UK diy 6 May 20th 07 10:27 AM
securing to plasterboard wall Newshound UK diy 0 May 15th 07 03:51 PM
Securing a stud wall to concrete floor Mike UK diy 8 July 1st 05 10:43 PM
Securing convector heater to MDF on plasterboard wall Adrian C UK diy 1 June 2nd 05 04:01 PM
Securing shower arm/head to wall John UK diy 2 October 29th 03 10:58 PM


All times are GMT +1. The time now is 07:52 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"