It is getting to the point where I am ready to install my main CU so just checking for any "gotchas" that I have not considered.

The unit I am going for is this

https://www.toolstation.com/mk-metal...er-unit/p77771

It has most of the MCBs I need and what is not there I can cannibalise from my existing CU. The CU will be populated as follows;

100A main switch

Garage - MCB with a 10mm2 T&E feed for now a 40A MCB. This will not be RCD protected as it will be run through voids or surface mounted. The feed is probably a bit overkill for now but I am looking ahead to possible EV charging. The garage does have an RCD in the garage CU hopefully restricting any problems to it rather than tripping the main CU.

Alarm - 16A MCB with 2.5mm2 T&E this feeds a couple of sockets in the loft for the wall wart PSUs for the alarm again not RCD protected as cable will run through voids and surface wired.

RCD 1 80A

Kitchen - ring main with 2.5mm2 T&E with 32A MCB
Lights - This is the main light circuit 1.5mm2 T&E with a 6A MCB
Hob - This is a 3.7KW induction hob which I am hoping to utilise the existing 6mm2 feed to our existing hob just transposing it to its new location. I will probably use the existing 32A MCB although a 20A should do
Oven - 5.6KW Like the hob I will be using the existing 6mm2 feed and 32A MCB

RCD 2 63A

Ring main - This is the rest of the house (bungalow) 2.5mm2 T&E & 32A MCB
Kitchen lights - 1.5mm2 T&E & 6A MCB
Boiler - 2.5mm2 & 16A MCB just in case we ditch the combi and go back to a system boiler with a possible immersion heater.
Shower - This is a temporary circuit as the shower will be replaced with a digital type when the bathroom is done over so I will utilise the current 4mm2 T&E & 32A MCB till then.

This will leave me with 5 spare ways two might get used with a surge arrestor if I decide to implement the full 18th Regs. However, seeing as these are rather expensive and seem to be optional the jury is still out on that one. As far as I know I have never in my lifetime of ownership of houses ever suffered a lightening strike or a surge but having said that the gods of mayhem will have one lined up as soon as I get this CU installed😵..

Richard


 
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
[OT-ish] Left over right, right over left David WE Roberts UK diy 14 October 25th 09 01:46 AM
DIY - Buy the right Tools - Learn how to do it right? Bill[_9_] Home Repair 19 April 28th 09 12:37 PM
The importance of the right kind of business uniform in dictating theimpression of your corporate business over the customer's minds is undeniable.With the right kind of business uniforms, your battle is half won. After all,everyone likes to see well [email protected] UK diy 0 April 19th 08 11:37 AM
Catnic Lintel, is this the right one? MikeT UK diy 2 August 4th 03 09:26 PM
Right angle TV cable plugs Snowman UK diy 17 July 8th 03 10:51 PM


All times are GMT +1. The time now is 10:25 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"