H0V55-F cable
What is it? It doesn't seem to exist.
|
#2
Posted to uk.d-i-y
|
|||
|
|||
H0V55-F cable
Ah, cable from an alternate universe. I found a roll of cable when I was
clearing out to get the garage removed, it was cracking its insulation. I suspect that no longer exists either it went to a good gypsy family. Brian -- -- From the sofa of Brian Gaff - Blind user, so no pictures please! Today is Yesterdays Tomorrow. wrote in message ... What is it? It doesn't seem to exist. |
#3
Posted to uk.d-i-y
|
|||
|
|||
H0V55-F cable
|
#4
Posted to uk.d-i-y
|
|||
|
|||
H0V55-F cable
On Tuesday, 28 May 2019 08:52:07 UTC+1, Andy Burns wrote:
tabbypurr wrote: What is it? It doesn't seem to exist. H0V55-F doesn't seem to be a valid code, as per https://www.peakcables.co.uk/european-system-cenelec-codes Pre-sizzly. But an appliance calls for it and no other Maybe it means H05VF, which would be 500v PVC flexible. Since the cable is never moved I don't see it needing flexibility. Anyway, it can't get what it's asking for, so it's then down to my judgement. NT |
#6
Posted to uk.d-i-y
|
|||
|
|||
H0V55-F cable
|
#7
Posted to uk.d-i-y
|
|||
|
|||
H0V55-F cable
On 29/05/2019 22:13, Robin wrote:
On 28/05/2019 09:32, wrote: On Tuesday, 28 May 2019 08:52:07 UTC+1, Andy BurnsĀ* wrote: tabbypurr wrote: What is it? It doesn't seem to exist. H0V55-F doesn't seem to be a valid code, as per https://www.peakcables.co.uk/european-system-cenelec-codes Pre-sizzly. But an appliance calls for it and no other Maybe it means H05VF, which would be 500v PVC flexible. Since the cable is never moved I don't see it needing flexibility. Anyway, it can't get what it's asking for, so it's then down to my judgement. It's common enough when typing to transpose 2 keys (such as 5 and V) Bloody Romans -- Adam |
#8
Posted to uk.d-i-y
|
|||
|
|||
H0V55-F cable
On Wednesday, 29 May 2019 21:55:45 UTC+1, ARW wrote:
On 28/05/2019 09:32, tabbypurr wrote: On Tuesday, 28 May 2019 08:52:07 UTC+1, Andy Burns wrote: tabbypurr wrote: What is it? It doesn't seem to exist. H0V55-F doesn't seem to be a valid code, as per https://www.peakcables.co.uk/european-system-cenelec-codes Pre-sizzly. But an appliance calls for it and no other Maybe it means H05VF, which would be 500v PVC flexible. Since the cable is never moved I don't see it needing flexibility. Anyway, it can't get what it's asking for, so it's then down to my judgement. Unless you tell us what it is that you want to use it for, then yes. electric hob. T&E will be fine. |
#9
Posted to uk.d-i-y
|
|||
|
|||
H0V55-F cable
wrote:
On Wednesday, 29 May 2019 21:55:45 UTC+1, ARW wrote: On 28/05/2019 09:32, tabbypurr wrote: On Tuesday, 28 May 2019 08:52:07 UTC+1, Andy Burns wrote: tabbypurr wrote: What is it? It doesn't seem to exist. H0V55-F doesn't seem to be a valid code, as per https://www.peakcables.co.uk/european-system-cenelec-codes Pre-sizzly. But an appliance calls for it and no other Maybe it means H05VF, which would be 500v PVC flexible. Since the cable is never moved I don't see it needing flexibility. Anyway, it can't get what it's asking for, so it's then down to my judgement. Unless you tell us what it is that you want to use it for, then yes. electric hob. T&E will be fine. I suspect that that is only true if it has been specifically designed so that the cable entry parts do not get hot in normal use. That applies to most UK market cookers, I have no idea about hobs; or foreign items. If the makers want a heat resistant cable (hard to say in this case if the actually want a non-existent cable) then not using one is probably a breach of regulations. -- Roger Hayter |
#10
Posted to uk.d-i-y
|
|||
|
|||
H0V55-F cable
On Thursday, 30 May 2019 09:26:31 UTC+1, Roger Hayter wrote:
tabbypurr wrote: On Wednesday, 29 May 2019 21:55:45 UTC+1, ARW wrote: On 28/05/2019 09:32, tabbypurr wrote: On Tuesday, 28 May 2019 08:52:07 UTC+1, Andy Burns wrote: tabbypurr wrote: What is it? It doesn't seem to exist. H0V55-F doesn't seem to be a valid code, as per https://www.peakcables.co.uk/european-system-cenelec-codes Pre-sizzly. But an appliance calls for it and no other Maybe it means H05VF, which would be 500v PVC flexible. Since the cable is never moved I don't see it needing flexibility. Anyway, it can't get what it's asking for, so it's then down to my judgement. Unless you tell us what it is that you want to use it for, then yes. electric hob. T&E will be fine. I suspect that that is only true if it has been specifically designed so that the cable entry parts do not get hot in normal use. That applies to most UK market cookers, I have no idea about hobs; or foreign items. If the makers want a heat resistant cable (hard to say in this case if the actually want a non-existent cable) then not using one is probably a breach of regulations. The mfrs want a nonexistant cable. That's not going to happen. Some hob mfrs say 2.5 T&E is fine, some want 4mm even when peak current draw, without applying diversity, is within 2.5's rated ampacity. The reason for the latter is down to heat, the hob applies some heat to the cable and in some cases that plus current heating of the cable might be too much. NT |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
USB datacomm cable for USB datacomm cable for SonyEricsson cellphone J300i | Electronics Repair | |||
extending coax cable to cable-modem | UK diy | |||
For the Cable Guys: Coax cable Splitter Q. | Home Repair | |||
Cable gland for armoured cable | UK diy | |||
Pulling cable through with existing one / Clipping cable in loft | UK diy |