Default Soil plumbing

The chalet bungalow upstairs bathroom.

Are there likely to be any issues with arranging a short 45 deg. fall in
the toilet waste pipe?

The current plan is a vertical outfall terminated at a manifold above
the soffit. There is insufficient space to get this high enough to
accept a full *horizontal* run. Probably 2m level, 45 deg. bend, 800mm
and another 45 deg. to the manifold.

I will arrange a vented (AAV) stack inboard to be higher than the basin
overflow.
--
Tim Lamb
  #2   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 25,191
Default Soil plumbing

On 07/08/2018 08:47, Tim Lamb wrote:
The chalet bungalow upstairs bathroom.

Are there likely to be any issues with arranging a short 45 deg. fall in
the toilet waste pipe?


Generally best of you can do it near the source end, but usually ok so
long as most of the run is within the recommended falls (typically
between 1 in 10 and 1 in 80 for 110mm soil pipe).

Its quite common to need a little bit of pipe height adjustment near
soil stacks for example.

The current plan is a vertical outfall terminated at a manifold above
the soffit. There is insufficient space to get this high enough to
accept a full *horizontal* run. Probably 2m level, 45 deg. bend, 800mm
and another 45 deg. to the manifold.

I will arrange a vented (AAV) stack inboard to be higher than the basin
overflow.



--
Cheers,

John.

/================================================== ===============\
| Internode Ltd - http://www.internode.co.uk |
|-----------------------------------------------------------------|
| John Rumm - john(at)internode(dot)co(dot)uk |
\================================================= ================/
  #3   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 6,938
Default Soil plumbing

In message , John
Rumm writes
On 07/08/2018 08:47, Tim Lamb wrote:
The chalet bungalow upstairs bathroom.
Are there likely to be any issues with arranging a short 45 deg.
fall in the toilet waste pipe?


Generally best of you can do it near the source end, but usually ok so
long as most of the run is within the recommended falls (typically
between 1 in 10 and 1 in 80 for 110mm soil pipe).

Its quite common to need a little bit of pipe height adjustment near
soil stacks for example.

The current plan is a vertical outfall terminated at a manifold above
the soffit. There is insufficient space to get this high enough to
accept a full *horizontal* run. Probably 2m level, 45 deg. bend, 800mm
and another 45 deg. to the manifold.
I will arrange a vented (AAV) stack inboard to be higher than the
basin overflow.


OK. Sadly the basin waste can't conveniently be used as a flush.

--
Tim Lamb
  #4   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 25
Default Soil plumbing


"Tim Lamb" wrote in message
...
The chalet bungalow upstairs bathroom.

Are there likely to be any issues with arranging a short 45 deg. fall in
the toilet waste pipe?

The current plan is a vertical outfall terminated at a manifold above the
soffit. There is insufficient space to get this high enough to accept a
full *horizontal* run. Probably 2m level, 45 deg. bend, 800mm and another
45 deg. to the manifold.


the water will leave the solids behind......

I will arrange a vented (AAV) stack inboard to be higher than the basin
overflow.


that is going to be noisey .......


  #5   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 3,080
Default Soil plumbing

On 07/08/2018 08:47, Tim Lamb wrote:
The chalet bungalow upstairs bathroom.

Are there likely to be any issues with arranging a short 45 deg. fall in
the toilet waste pipe?

The current plan is a vertical outfall terminated at a manifold above
the soffit. There is insufficient space to get this high enough to
accept a full *horizontal* run. Probably 2m level, 45 deg. bend, 800mm
and another 45 deg. to the manifold.


Our second toilet exits through the wall, turns 90° and then immediately
descends at 45° for about 800mm, before changing again to a normal
"horizontal" run. There was no choice, as there was a window half-way
down the stairs, between the toilet and the stack, preventing a straight
run. It has worked fine for 9 years now, but from the outside, it is
quite a bit noisier than the pipe from the other toilet.

SteveW


  #6   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 6,938
Default Soil plumbing

In message , Steve Walker
writes
On 07/08/2018 08:47, Tim Lamb wrote:
The chalet bungalow upstairs bathroom.
Are there likely to be any issues with arranging a short 45 deg.
fall in the toilet waste pipe?
The current plan is a vertical outfall terminated at a manifold
above the soffit. There is insufficient space to get this high enough
to accept a full *horizontal* run. Probably 2m level, 45 deg. bend,
800mm and another 45 deg. to the manifold.


Our second toilet exits through the wall, turns 90° and then
immediately descends at 45° for about 800mm, before changing again to a
normal "horizontal" run. There was no choice, as there was a window
half-way down the stairs, between the toilet and the stack, preventing
a straight run. It has worked fine for 9 years now, but from the
outside, it is quite a bit noisier than the pipe from the other toilet.


Hmm.. I'll let you know how I get on:-)

--
Tim Lamb
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Fertilizing rocky soil where it's half soil half stones (and no dirt) Danny D.[_16_] Home Repair 180 September 13th 16 05:51 PM
Help: Soil Connection Options for Under Stairs Macerator (Soil Stack/ Manhole) GC UK diy 0 March 23rd 08 12:32 PM
plumbing - soil waste [email protected] UK diy 2 October 25th 05 02:51 PM
Plumbing wash m/c into main soil pipe? joey1522 UK diy 2 January 14th 05 03:04 PM
Leak at plastic soil pipe to clay soil pipe join Darren UK diy 2 October 12th 04 09:49 PM


All times are GMT +1. The time now is 03:35 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"