UK diy (uk.d-i-y) For the discussion of all topics related to diy (do-it-yourself) in the UK. All levels of experience and proficency are welcome to join in to ask questions or offer solutions.

Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Lawrence Raybould
 
Posts: n/a
Default Ariston Microgenus 23 combi boiler

Ariston Microgenus 23 combi boiler

My boiler recently developed a fault where I had central heating but
no domestic hot water (stone cold). I was advised to fit a new
diverter valve which I did.

The problem I have now is that I still have central heating but the
domestic hot water only runs hot for 2 to 3 minutes then runs luke
warm although the boiler is still fired up.

Does anyone have any suggestions what is causing this to happen?
  #2   Report Post  
BillR
 
Posts: n/a
Default Ariston Microgenus 23 combi boiler

Lawrence Raybould wrote:
Ariston Microgenus 23 combi boiler

My boiler recently developed a fault where I had central heating but
no domestic hot water (stone cold). I was advised to fit a new
diverter valve which I did.

The problem I have now is that I still have central heating but the
domestic hot water only runs hot for 2 to 3 minutes then runs luke
warm although the boiler is still fired up.

Does anyone have any suggestions what is causing this to happen?


Flow switch?


  #3   Report Post  
Ed Sirett
 
Posts: n/a
Default Ariston Microgenus 23 combi boiler

On Tue, 06 Jan 2004 12:20:57 +0000, Lawrence Raybould wrote:

Ariston Microgenus 23 combi boiler

My boiler recently developed a fault where I had central heating but
no domestic hot water (stone cold). I was advised to fit a new
diverter valve which I did.

The problem I have now is that I still have central heating but the
domestic hot water only runs hot for 2 to 3 minutes then runs luke
warm although the boiler is still fired up.

Does anyone have any suggestions what is causing this to happen?


1) Temperature sensor(s) out of spec?
2) Diverter valve letting primary water to CH during DHW mode.

I'm fairly sure this boiler does not have any sort of thermal store but
otherwise the behaviour is exactly as it would be if it had.

--
Ed Sirett - Property maintainer and registered gas fitter.
The FAQ for uk.diy is at www.diyfaq.org.uk
Gas fitting FAQ http://www.makewrite.demon.co.uk/GasFitting.html
Sealed CH FAQ http://www.makewrite.demon.co.uk/SealedCH.html


  #4   Report Post  
IMM
 
Posts: n/a
Default Ariston Microgenus 23 combi boiler


"Ed Sirett" wrote in message
news
On Tue, 06 Jan 2004 12:20:57 +0000, Lawrence Raybould wrote:

Ariston Microgenus 23 combi boiler

My boiler recently developed a fault where I had central heating but
no domestic hot water (stone cold). I was advised to fit a new
diverter valve which I did.

The problem I have now is that I still have central heating but the
domestic hot water only runs hot for 2 to 3 minutes then runs luke
warm although the boiler is still fired up.

Does anyone have any suggestions what is causing this to happen?


1) Temperature sensor(s) out of spec?
2) Diverter valve letting primary water to CH during DHW mode.

I'm fairly sure this boiler does not have any sort of thermal store but
otherwise the behaviour is exactly as it would be if it had.


It has an electric diverter valve. It has a flow switch which detects flow
and energises the diverter valve. Had the valve actually gone? The
actuator can be changed, rather than the whole valve inc water section.



---
--

Checked by AVG anti-virus system (http://www.grisoft.com).
Version: 6.0.555 / Virus Database: 347 - Release Date: 23/12/2003


Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Alpha Combi Boiler CB24 Reteplav UK diy 2 November 1st 06 03:50 PM
leaking heat exchanger in combi boiler (was:Vokera Linea 24 - heatexchanger ) Reestit Mutton UK diy 19 November 19th 03 12:55 PM
Hot water problem with my combi boiler Andrew Bainbridge UK diy 1 October 25th 03 10:21 PM
New Combi boiler GB UK diy 7 September 7th 03 11:34 PM
Ariston STYX Combi boiler problems Sharma UK diy 5 July 15th 03 11:15 PM


All times are GMT +1. The time now is 03:27 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"