Ariston Microgenus 23 combi boiler
My boiler recently developed a fault where I had central heating but no domestic hot water (stone cold). I was advised to fit a new diverter valve which I did. The problem I have now is that I still have central heating but the domestic hot water only runs hot for 2 to 3 minutes then runs luke warm although the boiler is still fired up. Does anyone have any suggestions what is causing this to happen? |
#2
![]() |
|||
|
|||
![]()
Lawrence Raybould wrote:
Ariston Microgenus 23 combi boiler My boiler recently developed a fault where I had central heating but no domestic hot water (stone cold). I was advised to fit a new diverter valve which I did. The problem I have now is that I still have central heating but the domestic hot water only runs hot for 2 to 3 minutes then runs luke warm although the boiler is still fired up. Does anyone have any suggestions what is causing this to happen? Flow switch? |
#3
![]() |
|||
|
|||
![]()
On Tue, 06 Jan 2004 12:20:57 +0000, Lawrence Raybould wrote:
Ariston Microgenus 23 combi boiler My boiler recently developed a fault where I had central heating but no domestic hot water (stone cold). I was advised to fit a new diverter valve which I did. The problem I have now is that I still have central heating but the domestic hot water only runs hot for 2 to 3 minutes then runs luke warm although the boiler is still fired up. Does anyone have any suggestions what is causing this to happen? 1) Temperature sensor(s) out of spec? 2) Diverter valve letting primary water to CH during DHW mode. I'm fairly sure this boiler does not have any sort of thermal store but otherwise the behaviour is exactly as it would be if it had. -- Ed Sirett - Property maintainer and registered gas fitter. The FAQ for uk.diy is at www.diyfaq.org.uk Gas fitting FAQ http://www.makewrite.demon.co.uk/GasFitting.html Sealed CH FAQ http://www.makewrite.demon.co.uk/SealedCH.html |
#4
![]() |
|||
|
|||
![]() "Ed Sirett" wrote in message news ![]() On Tue, 06 Jan 2004 12:20:57 +0000, Lawrence Raybould wrote: Ariston Microgenus 23 combi boiler My boiler recently developed a fault where I had central heating but no domestic hot water (stone cold). I was advised to fit a new diverter valve which I did. The problem I have now is that I still have central heating but the domestic hot water only runs hot for 2 to 3 minutes then runs luke warm although the boiler is still fired up. Does anyone have any suggestions what is causing this to happen? 1) Temperature sensor(s) out of spec? 2) Diverter valve letting primary water to CH during DHW mode. I'm fairly sure this boiler does not have any sort of thermal store but otherwise the behaviour is exactly as it would be if it had. It has an electric diverter valve. It has a flow switch which detects flow and energises the diverter valve. Had the valve actually gone? The actuator can be changed, rather than the whole valve inc water section. --- -- Checked by AVG anti-virus system (http://www.grisoft.com). Version: 6.0.555 / Virus Database: 347 - Release Date: 23/12/2003 |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Alpha Combi Boiler CB24 | UK diy | |||
leaking heat exchanger in combi boiler (was:Vokera Linea 24 - heatexchanger ) | UK diy | |||
Hot water problem with my combi boiler | UK diy | |||
New Combi boiler | UK diy | |||
Ariston STYX Combi boiler problems | UK diy |