Hello,
I have an old-style Y-plan system; HW and CH can run independently from each other. I would like to replace my Sangamo 410 CH programmer with a 7-day one, like this: https://www.plumbnation.co.uk/site/h...el-programmer/ Is this a straighforward replacement? I don't have yhe Sangamo installation manual. Cheers, Kostas -- Emails to this address are dropped. |
#2
Posted to uk.d-i-y
|
|||
|
|||
Replacememt for Sangamo 410 CH programmer
On Friday, March 6, 2015 at 10:31:25 PM UTC, Kostas Kavoussanakis wrote:
Hello, I have an old-style Y-plan system; HW and CH can run independently from each other. I would like to replace my Sangamo 410 CH programmer with a 7-day one, like this: https://www.plumbnation.co.uk/site/h...el-programmer/ Is this a straighforward replacement? I don't have yhe Sangamo installation manual. It should be NT |
#3
Posted to uk.d-i-y
|
|||
|
|||
Replacememt for Sangamo 410 CH programmer
On 06/03/2015 22:31, Kostas Kavoussanakis wrote:
Hello, I have an old-style Y-plan system; HW and CH can run independently from each other. I would like to replace my Sangamo 410 CH programmer with a 7-day one, like this: https://www.plumbnation.co.uk/site/h...el-programmer/ Is this a straighforward replacement? I don't have yhe Sangamo installation manual. Cheers, Kostas http://sangamo.co.uk/wp-content/uplo...User-Inst1.pdf It doesn't look like a one for one swap, one has a back box with 8 terminals the other has a back box with 6 terminals. You will have to work out the wiring to your existing programmer and that required for the new one and maybe use an intermediate wiring junction box Example box http://tinyurl.com/kykun6z but cheaper elsewhere -- mailto: news {at} admac {dot] myzen {dot} co {dot} uk |
#4
Posted to uk.d-i-y
|
|||
|
|||
Replacememt for Sangamo 410 CH programmer
On Friday, March 6, 2015 at 11:19:44 PM UTC, alan_m wrote:
On 06/03/2015 22:31, Kostas Kavoussanakis wrote: Hello, I have an old-style Y-plan system; HW and CH can run independently from each other. I would like to replace my Sangamo 410 CH programmer with a 7-day one, like this: https://www.plumbnation.co.uk/site/h...el-programmer/ Is this a straighforward replacement? I don't have yhe Sangamo installation manual. Cheers, Kostas http://sangamo.co.uk/wp-content/uplo...User-Inst1.pdf It doesn't look like a one for one swap, one has a back box with 8 terminals the other has a back box with 6 terminals. You will have to work out the wiring to your existing programmer and that required for the new one and maybe use an intermediate wiring junction box Example box http://tinyurl.com/kykun6z but cheaper elsewhere The old Sangamo has 4&5 connected, so really 7 terminals. It also has off contacts for both HW & CH, one of which isn't needed for Y plan. So it should indeed be a straight swap. The OP does of course need to identify which terminal is which on each device. NT |
#6
Posted to uk.d-i-y
|
|||
|
|||
Replacememt for Sangamo 410 CH programmer
On Sunday, March 8, 2015 at 7:38:03 PM UTC, Kostas Kavoussanakis wrote:
On 07/03/2015 03:48, wrote: On Friday, March 6, 2015 at 11:19:44 PM UTC, alan_m wrote: On 06/03/2015 22:31, Kostas Kavoussanakis wrote: Hello, I have an old-style Y-plan system; HW and CH can run independently from each other. I would like to replace my Sangamo 410 CH programmer with a 7-day one, like this: https://www.plumbnation.co.uk/site/h...el-programmer/ Is this a straighforward replacement? I don't have yhe Sangamo installation manual. http://sangamo.co.uk/wp-content/uplo...User-Inst1.pdf It doesn't look like a one for one swap, one has a back box with 8 terminals the other has a back box with 6 terminals. You will have to work out the wiring to your existing programmer and that required for the new one and maybe use an intermediate wiring junction box Example box http://tinyurl.com/kykun6z but cheaper elsewhere The old Sangamo has 4&5 connected, so really 7 terminals. It also has off contacts for both HW & CH, one of which isn't needed for Y plan. So it should indeed be a straight swap. The OP does of course need to identify which terminal is which on each device. Thanks for this and for all the previous answers (the link to the Sangamo manual is very much appreciated, not that the other replied are not). I will take a look at the Honeywell manual and see if I can map one to the other, but this looks like it's beyond my capabilities, as I did not even manage to understand under what "Form" my set up would be. Cheers, Kostas You dont need to know what plan your system is, just identify what the terminals are on each contorller. They'll all be marked. NT |
#7
Posted to uk.d-i-y
|
|||
|
|||
Replacememt for Sangamo 410 CH programmer
"Kostas Kavoussanakis" wrote in message ... Hello, I have an old-style Y-plan system; HW and CH can run independently from each other. I would like to replace my Sangamo 410 CH programmer with a 7-day one, like this: https://www.plumbnation.co.uk/site/h...el-programmer/ Is this a straighforward replacement? I don't have yhe Sangamo installation manual. Cheers, Kostas I would think replacement should be reasonably straightforward. I recently replaced a dead Honeywell programmer with an ST9400C. Doddle. Very minor changes to wiring and a little bit of carpentry to set it nicely. FWIW this is probably the most user friendly programmer that I have ever come across. I've seen a few. Nick. |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Sangamo 410 Instructions | UK diy | |||
SANGAMO Powermeter KYWP 3oooW 120 VAC | Electronics Repair | |||
Replacement for Sangamo clock | UK diy | |||
Replacing Sangamo 410 programmer / timer - solution | UK diy | |||
Replacing Sangamo 410 programmer / timer | UK diy |