UK diy (uk.d-i-y) For the discussion of all topics related to diy (do-it-yourself) in the UK. All levels of experience and proficency are welcome to join in to ask questions or offer solutions.

Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 283
Default Extending gas bonding

There is an earth bonding cable running from the gas meter to the CU but has
been fitted to run over the surface in an unsightly way. To hide it I will
have to extend it and go the long way round. I understand bonding has now
been frowned upon - so before I embark on this awkward task - is it
necessary? (Edinburgh flat)

  #2   Report Post  
Posted to uk.d-i-y
ARW ARW is offline
external usenet poster
 
Posts: 10,161
Default Extending gas bonding

Geoff Pearson wrote:
There is an earth bonding cable running from the gas meter to the CU
but has been fitted to run over the surface in an unsightly way. To
hide it I will have to extend it and go the long way round. I
understand bonding has now been frowned upon - so before I embark on
this awkward task - is it necessary? (Edinburgh flat)


Main bonding is still needed!

a 10mm through crimp is what you need (and a pair of crimpers)


--
Adam


  #3   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 173
Default Extending gas bonding

"Geoff Pearson" wrote in
:

There is an earth bonding cable running from the gas meter
to the CU but has been fitted to run over the surface in an
unsightly way. To hide it I will have to extend it and go
the long way round. I understand bonding has now been
frowned upon - so before I embark on this awkward task - is
it necessary? (Edinburgh flat)


Electrical cross bonding for the gas meter is still a
requirement.

It is also required to run ubroken (no joins)

If your meter is outside then it is prefered that the
bonding connection should be as close as possible where
the pipe comes into the building on the inside.

--- news://freenews.netfront.net/ - complaints: ---
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Extending a fence fay UK diy 8 June 2nd 07 04:12 PM
Cross-bonding/earth bonding gas meter Jim UK diy 1 July 28th 06 09:19 PM
Extending Aerial John UK diy 8 December 16th 05 07:02 PM
Extending over a well David Clay UK diy 15 July 23rd 05 08:56 AM


All times are GMT +1. The time now is 09:55 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"