RCD Keeps tripping on new installation
Hi all.
New member here. I am a qualified, registered electrician and I have a mojor problem with a new installation and rewiring. I have rewired 6 new flats and fitted brand new cu's (B&Q £55 ones.. at customer choice!). Anyway, all rewire and fitting of consumer units of 5 flats are fine... however, the last one... did the rewire, fitted the cu, proceeded to test and the rcd for the kitchen/bathroom is tripping, even though none of the switches are on for the mcb's in the kitchen load of the cu. The kitchen load comprises of, 3 double sockets, 1 radiator switched spur (RM with sockets), 1 cooker switch and a bathroom wall heater (RM with sockets). When I remove the earths from the kitchen/bathroom RM, the RCD will stay on, but as soon as I touch either of the RM earth to the earth busbar, it will trip the RCD. Also, I can leave the RM earths in and remove the Neutral RM cables and it will be fine...but as soon as I touch the RM neutral to the busbar, it trips. All connections are fine... to the correct busbars, etc. I am miffed on this one, and any help would be greatl;y appreciated! Thanks. |