Soil pipe -- to replace or not to replace
Hello -- first post here after reading for a long time and picking up
lots of valuable advice. I'm going to completely replace our bathroom over the next few weeks. Before doing anything internally I was planning to replace the soil stack. The connection to the toilet is a mess -- years of bodging and putty and a cheap loo that wobbles and leaks because it hasn't been screwed to the wall. Here's a picture. Note that I didn't install this! http://tinypic.com/r/250htp1/6 But... now I find myself thinking how much easier it would be if I didn't have to get rid of the whole thing. The external pipework is old but sound. I don't want to fit a new toilet to a knackered pipe -- but does anyone have any thoughts about reusing what's there already? If I could saw/grind off the collar on the pipe and clean up the end then would a flexible pan connector make a decent seal? Would it help to use a long connector and push it further down the pipe than normal? The current (badly fitted) toilet is on a wooden plinth which will come out before the new toilet goes in. Is there likely to be a problem with the angle of the connector? Clearly the new one will need to be closer to the wall so it can be fixed in place. I'd rather not have to have a bit of wood between the back of the cistern and the wall. Any advice would be much appreciated. Two small children in the house mean that the quicker I can finish the project the better -- but if I'm going to have to bite the bullet and replace the whole thing then I might as well get on with it. Thanks in advance. James -- |
#2
Posted to uk.d-i-y
|
|||
|
|||
Soil pipe -- to replace or not to replace
James wrote:
Hello -- first post here after reading for a long time and picking up lots of valuable advice. I'm going to completely replace our bathroom over the next few weeks. Before doing anything internally I was planning to replace the soil stack. The connection to the toilet is a mess -- years of bodging and putty and a cheap loo that wobbles and leaks because it hasn't been screwed to the wall. Here's a picture. Note that I didn't install this! http://tinypic.com/r/250htp1/6 But... now I find myself thinking how much easier it would be if I didn't have to get rid of the whole thing. The external pipework is old but sound. I don't want to fit a new toilet to a knackered pipe -- but does anyone have any thoughts about reusing what's there already? If I could saw/grind off the collar on the pipe and clean up the end then would a flexible pan connector make a decent seal? Would it help to use a long connector and push it further down the pipe than normal? The current (badly fitted) toilet is on a wooden plinth which will come out before the new toilet goes in. Is there likely to be a problem with the angle of the connector? Clearly the new one will need to be closer to the wall so it can be fixed in place. I'd rather not have to have a bit of wood between the back of the cistern and the wall. Any advice would be much appreciated. Two small children in the house mean that the quicker I can finish the project the better -- but if I'm going to have to bite the bullet and replace the whole thing then I might as well get on with it. Thanks in advance. Is that a lead waste pipe to a cast iron soil stack? -- Adam |
#3
Posted to uk.d-i-y
|
|||
|
|||
Soil pipe -- to replace or not to replace
On 2012-07-03 20:50:57 +0000, ARWadsworth said:
Is that a lead waste pipe to a cast iron soil stack? Thanks for the reply. I don't think it's lead, although having never knowingly seen a lead waste pipe I'm happy to be proved wrong. For some reason that TinyPic link brings up a zoomed-in version of the photo. If you click on the image then you get a better view. There's a modern pan connector shoved into what looks like a bit of plastic pipe, which goes into the collar at a strange angle, then loads of putty and sealant packed around them all. I'd assumed everything except the plastic bit was cast iron, but I've just been up and tried to stick a fridge magnet to it, and it doesn't stick. It doesn't stick to the soil stack outside either. Abestos? Or maybe I need a stronger magnet... James -- |
#4
Posted to uk.d-i-y
|
|||
|
|||
Soil pipe -- to replace or not to replace
James wrote:
On 2012-07-03 20:50:57 +0000, ARWadsworth said: Is that a lead waste pipe to a cast iron soil stack? Thanks for the reply. I don't think it's lead, although having never knowingly seen a lead waste pipe I'm happy to be proved wrong. For some reason that TinyPic link brings up a zoomed-in version of the photo. If you click on the image then you get a better view. There's a modern pan connector shoved into what looks like a bit of plastic pipe, which goes into the collar at a strange angle, then loads of putty and sealant packed around them all. I'd assumed everything except the plastic bit was cast iron, but I've just been up and tried to stick a fridge magnet to it, and it doesn't stick. It doesn't stick to the soil stack outside either. Abestos? Or maybe I need a stronger magnet... A photo from outside might give more clues. Where does the **** pipe go to? -- Adam |
#5
Posted to uk.d-i-y
|
|||
|
|||
Soil pipe -- to replace or not to replace
On 2012-07-03 21:14:31 +0000, ARWadsworth said:
James wrote: On 2012-07-03 20:50:57 +0000, ARWadsworth said: Is that a lead waste pipe to a cast iron soil stack? Thanks for the reply. I don't think it's lead, although having never knowingly seen a lead waste pipe I'm happy to be proved wrong. A photo from outside might give more clues. Not much to see out there at the moment, but I'll take one when it's light. Where does the **** pipe go to? It goes out through the wall then straight into the soil stack via a swept tee. The soil stack is outside, just to one side of the pipe. -- |
#6
Posted to uk.d-i-y
|
|||
|
|||
Soil pipe -- to replace or not to replace
On 2012-07-03 21:25:06 +0000, James said:
On 2012-07-03 21:14:31 +0000, ARWadsworth said: A photo from outside might give more clues. Not much to see out there at the moment, but I'll take one when it's light. Ok -- here's a couple more pictures of outside: http://tinypic.com/r/kef4gi/6 http://tinypic.com/r/29zzlvs/6 It's noticeable that there's no rust on the pipework, which I suppose may suggest it's not cast iron. Look at the top section of the second picture where the paint has come of. It doesn't look like metal to me, at least from a distance. Next door's soil stack is identical but has lost a lot more paint, and that hasn't rusted either. The white plastic pipe is coming from a Saniflo at the front of the house and will be removed when I do the bathroom. As an aside, and for the benefit of future readers searching the archives for helpful advice about macerating toilets: If you move into a house with a Saniflo, assume that you'll want to put it in a skip within the first year of living there. Anything you read online about them being (quite literally) full of **** is entirely true. Unless you live in a converted basement, you do not want a Saniflo, however badly you need another bathroom. Move house instead. -- James |
#7
Posted to uk.d-i-y
|
|||
|
|||
Soil pipe -- to replace or not to replace
On 03/07/2012 22:07, James wrote:
On 2012-07-03 20:50:57 +0000, ARWadsworth said: Is that a lead waste pipe to a cast iron soil stack? Thanks for the reply. I don't think it's lead, although having never knowingly seen a lead waste pipe I'm happy to be proved wrong. For some reason that TinyPic link brings up a zoomed-in version of the photo. If you click on the image then you get a better view. There's a modern pan connector shoved into what looks like a bit of plastic pipe, which goes into the collar at a strange angle, then loads of putty and sealant packed around them all. I'd assumed everything except the plastic bit was cast iron, but I've just been up and tried to stick a fridge magnet to it, and it doesn't stick. It doesn't stick to the soil stack outside either. Abestos? Or maybe I need a stronger magnet... James Cement asbestos used to be used sometimes for things like rainfall downpipes in factories and garages, but I have never come across it used in soil pipes. If it's not magnetic my money would be on (relatively) modern plastic (usually ABS or PVC). I *think* the sizes for soil pipes are to a British Standard so modern parts should mix and match. This isn't true for sink wastes which were a real dogs breakfast when they came in in the 1960's and 70's. Who was it made the awful brown stuff? |
#8
Posted to uk.d-i-y
|
|||
|
|||
Soil pipe -- to replace or not to replace
On Tue, 03 Jul 2012 22:37:19 +0100, newshound wrote:
On 03/07/2012 22:07, James wrote: On 2012-07-03 20:50:57 +0000, ARWadsworth said: Is that a lead waste pipe to a cast iron soil stack? Thanks for the reply. I don't think it's lead, although having never knowingly seen a lead waste pipe I'm happy to be proved wrong. For some reason that TinyPic link brings up a zoomed-in version of the photo. If you click on the image then you get a better view. There's a modern pan connector shoved into what looks like a bit of plastic pipe, which goes into the collar at a strange angle, then loads of putty and sealant packed around them all. I'd assumed everything except the plastic bit was cast iron, but I've just been up and tried to stick a fridge magnet to it, and it doesn't stick. It doesn't stick to the soil stack outside either. Abestos? Or maybe I need a stronger magnet... James Cement asbestos used to be used sometimes for things like rainfall downpipes in factories and garages, but I have never come across it used in soil pipes. If it's not magnetic my money would be on (relatively) modern plastic (usually ABS or PVC). I *think* the sizes for soil pipes are to a British Standard so modern parts should mix and match. This isn't true for sink wastes which were a real dogs breakfast when they came in in the 1960's and 70's. Who was it made the awful brown stuff? My house was council-built c. 1950 and the soil pipe is asbestos cement with lead through the wall. My main fear, after 60+ years, is that the lead will start leaking into the cavity. -- Peter. The gods will stay away whilst religions hold sway |
#9
Posted to uk.d-i-y
|
|||
|
|||
Soil pipe -- to replace or not to replace
On 03/07/2012 22:07, James wrote:
.... I'd assumed everything except the plastic bit was cast iron, but I've just been up and tried to stick a fridge magnet to it, and it doesn't stick. It doesn't stick to the soil stack outside either. Abestos? Or maybe I need a stronger magnet... You can tell how much heat treatment cast iron has had by changes in its magnetic properties, so don't expect it to react like mild steel. Thick layers of paint also reduce the grip of most magnets. I suggest a *much* stronger magnet. Colin Bignell |
#10
Posted to uk.d-i-y
|
|||
|
|||
Soil pipe -- to replace or not to replace
Nightjar wrote:
On 03/07/2012 22:07, James wrote: ... I'd assumed everything except the plastic bit was cast iron, but I've just been up and tried to stick a fridge magnet to it, and it doesn't stick. It doesn't stick to the soil stack outside either. Abestos? Or maybe I need a stronger magnet... You can tell how much heat treatment cast iron has had by changes in its magnetic properties, so don't expect it to react like mild steel. Thick layers of paint also reduce the grip of most magnets. I suggest a *much* stronger magnet. Colin Bignell I think TNPs right though. Looks like a clay pipe to me. Scraping a bit of paint off would be a good start. Tim |
#11
Posted to uk.d-i-y
|
|||
|
|||
Soil pipe -- to replace or not to replace
On 2012-07-04 12:16:52 +0000, Tim said:
Nightjar wrote: You can tell how much heat treatment cast iron has had by changes in its magnetic properties, so don't expect it to react like mild steel. Thick layers of paint also reduce the grip of most magnets. I suggest a *much* stronger magnet. Colin Bignell Predictably enough, the "much stronger magnet" that I remember salvaging from something a couple of years ago has completely disappeared. I think TNPs right though. Looks like a clay pipe to me. Scraping a bit of paint off would be a good start. Good idea. This is what it looks like under the paint: http://tinypic.com/r/1986qh/6 It's not cold to the touch. I'm beginning to suspect that Tim and TNP are right. If it's clay, how practical is it to cut without damage? Chain-style pipe cutter? Failing that, is the outside joint likely to come apart? -- James |
#12
Posted to uk.d-i-y
|
|||
|
|||
Soil pipe -- to replace or not to replace
On 04/07/2012 13:16, Tim wrote:
Nightjar wrote: On 03/07/2012 22:07, James wrote: ... I'd assumed everything except the plastic bit was cast iron, but I've just been up and tried to stick a fridge magnet to it, and it doesn't stick. It doesn't stick to the soil stack outside either. Abestos? Or maybe I need a stronger magnet... You can tell how much heat treatment cast iron has had by changes in its magnetic properties, so don't expect it to react like mild steel. Thick layers of paint also reduce the grip of most magnets. I suggest a *much* stronger magnet. Colin Bignell I think TNPs right though. Looks like a clay pipe to me. Scraping a bit of paint off would be a good start. Clay would be an odd choice for connecting to an external soil stack. Colin Bignell |
#13
Posted to uk.d-i-y
|
|||
|
|||
Soil pipe -- to replace or not to replace
On 03/07/2012 21:50, ARWadsworth wrote:
James wrote: Hello -- first post here after reading for a long time and picking up lots of valuable advice. I'm going to completely replace our bathroom over the next few weeks. Before doing anything internally I was planning to replace the soil stack. The connection to the toilet is a mess -- years of bodging and putty and a cheap loo that wobbles and leaks because it hasn't been screwed to the wall. Here's a picture. Note that I didn't install this! http://tinypic.com/r/250htp1/6 But... now I find myself thinking how much easier it would be if I didn't have to get rid of the whole thing. The external pipework is old but sound. I don't want to fit a new toilet to a knackered pipe -- but does anyone have any thoughts about reusing what's there already? If I could saw/grind off the collar on the pipe and clean up the end then would a flexible pan connector make a decent seal? Would it help to use a long connector and push it further down the pipe than normal? The current (badly fitted) toilet is on a wooden plinth which will come out before the new toilet goes in. Is there likely to be a problem with the angle of the connector? Clearly the new one will need to be closer to the wall so it can be fixed in place. I'd rather not have to have a bit of wood between the back of the cistern and the wall. Any advice would be much appreciated. Two small children in the house mean that the quicker I can finish the project the better -- but if I'm going to have to bite the bullet and replace the whole thing then I might as well get on with it. Thanks in advance. Is that a lead waste pipe to a cast iron soil stack? Looks a bit like an iron waste pipe to me; don't recognise the collar at all. What happens outside? One option might be to fit a new plastic pipe through the wall to an existing iron stack outside (which is what I have). Then you can have nice modern unbodged pipework inside the house. |
#14
Posted to uk.d-i-y
|
|||
|
|||
Soil pipe -- to replace or not to replace
In article om,
newshound writes Looks a bit like an iron waste pipe to me; don't recognise the collar at all. What happens outside? One option might be to fit a new plastic pipe through the wall to an existing iron stack outside (which is what I have). Then you can have nice modern unbodged pipework inside the house. Agree it is likely cast iron, I have seen one with a similar collar from a 60's build, the collar was sealed using lead wool compacted with an offset compacter/chisel type tool. I'd cut it off 2" or so from the wall to get a lower entry and use a flexible pan connector to mate with the inside of the pipe. They're meant to be self sealing but I'd add sanitary silicone to the compressible vanes to make sure. No need to disturb a cast iron stack in good condition, it should last a century. Hopefully the building is not 99yrs old ;-). -- fred it's a ba-na-na . . . . |
#15
Posted to uk.d-i-y
|
|||
|
|||
Soil pipe -- to replace or not to replace
On 2012-07-03 21:35:07 +0000, fred said:
Agree it is likely cast iron, I have seen one with a similar collar from a 60's build, the collar was sealed using lead wool compacted with an offset compacter/chisel type tool. I'm still not sure. Other than a magnet, is there a test? I'd cut it off 2" or so from the wall to get a lower entry and use a flexible pan connector to mate with the inside of the pipe. They're meant to be self sealing but I'd add sanitary silicone to the compressible vanes to make sure. That's pretty much what I had in mind. How far down the pipe would you aim to get the flexible connector? Does further = better? I suppose there's a danger it won't seal properly if it's halfway round a bend instead of in a straight section. No need to disturb a cast iron stack in good condition, it should last a century. Hopefully the building is not 99yrs old ;-). Probably about 120! But I suspect the first bathroom was installed in the 1930s... Thanks for the advice. -- James |
#16
Posted to uk.d-i-y
|
|||
|
|||
Soil pipe -- to replace or not to replace
In article 2012070413331143447-info@coukinvalid, James
writes On 2012-07-03 21:35:07 +0000, fred said: Agree it is likely cast iron, I have seen one with a similar collar from a 60's build, the collar was sealed using lead wool compacted with an offset compacter/chisel type tool. I'm still not sure. Other than a magnet, is there a test? I'd cut it off 2" or so from the wall to get a lower entry and use a flexible pan connector to mate with the inside of the pipe. They're meant to be self sealing but I'd add sanitary silicone to the compressible vanes to make sure. That's pretty much what I had in mind. How far down the pipe would you aim to get the flexible connector? Does further = better? I suppose there's a danger it won't seal properly if it's halfway round a bend instead of in a straight section. It wont bend until it is through the wall so you have at least 4" straight there so nowt to worry about. You want the pan connector to go into the pipe until it bottoms out or until all the fins are in which could be 2-4" depending on type. From your other pics it's def a cast iron stack, that straight vent section at the top may be something lighter. Other comments about the pipe being brittle and cracking are valid hence my suggestion to cut it 2" from the wall so that you can have another go if it breaks. Maybe start further away then re-cut closer once you have more confidence also noting that the further from the wall the higher the pipe will be and that it will need to match your new pan. My choice could be a 110mm angle grinder with cutting disk, mark your cut line, score round first a mm or 2 with the grinder then go progressively deeper until it is cut. Chose the right distance and you can use a straight pan connector, which is better than flex. Smart move would be to get a few likely bits in from a place like BES, they're not expensive and it means you have exactly the right bit to hand no matter what. See the bottom of this page: http://www.bes.ltd.uk/products/121.asp Distance from the wall will be set by your pan/cistern combo, close coupled? Re comments about breaking into cast iron joints/stacks, just don't go there unless you have to, there is a high risk of breaking the collar if you do as it is all so brittle. When you do have to do it, you smash the ingoing pipe with a hammer, stuff newspaper in the hole to catch the bits then have to chisel out the stub of the pipe form the socket so not unsurprising that it often ends in tears. No need to disturb a cast iron stack in good condition, it should last a century. Hopefully the building is not 99yrs old ;-). Probably about 120! But I suspect the first bathroom was installed in the 1930s... Thanks for the advice. You're welcome and good luck! -- fred it's a ba-na-na . . . . |
#17
Posted to uk.d-i-y
|
|||
|
|||
Soil pipe -- to replace or not to replace
newshound wrote:
On 03/07/2012 21:50, ARWadsworth wrote: James wrote: Hello -- first post here after reading for a long time and picking up lots of valuable advice. I'm going to completely replace our bathroom over the next few weeks. Before doing anything internally I was planning to replace the soil stack. The connection to the toilet is a mess -- years of bodging and putty and a cheap loo that wobbles and leaks because it hasn't been screwed to the wall. Here's a picture. Note that I didn't install this! http://tinypic.com/r/250htp1/6 But... now I find myself thinking how much easier it would be if I didn't have to get rid of the whole thing. The external pipework is old but sound. I don't want to fit a new toilet to a knackered pipe -- but does anyone have any thoughts about reusing what's there already? If I could saw/grind off the collar on the pipe and clean up the end then would a flexible pan connector make a decent seal? Would it help to use a long connector and push it further down the pipe than normal? The current (badly fitted) toilet is on a wooden plinth which will come out before the new toilet goes in. Is there likely to be a problem with the angle of the connector? Clearly the new one will need to be closer to the wall so it can be fixed in place. I'd rather not have to have a bit of wood between the back of the cistern and the wall. Any advice would be much appreciated. Two small children in the house mean that the quicker I can finish the project the better -- but if I'm going to have to bite the bullet and replace the whole thing then I might as well get on with it. Thanks in advance. Is that a lead waste pipe to a cast iron soil stack? Looks a bit like an iron waste pipe to me; don't recognise the collar at all. What happens outside? One option might be to fit a new plastic pipe through the wall to an existing iron stack outside (which is what I have). Then you can have nice modern unbodged pipework inside the house. Looks like clay to me. Could be a bugger to cut without shattering -- To people who know nothing, anything is possible. To people who know too much, it is a sad fact that they know how little is really possible - and how hard it is to achieve it. |
#18
Posted to uk.d-i-y
|
|||
|
|||
Soil pipe -- to replace or not to replace
On 2012-07-03 21:16:27 +0000, newshound said:
Looks a bit like an iron waste pipe to me; don't recognise the collar at all. What happens outside? One option might be to fit a new plastic pipe through the wall to an existing iron stack outside (which is what I have). Then you can have nice modern unbodged pipework inside the house. Thanks for the reply. I've just posted links to another couple of pictures of the outside -- see my reply to Adam. Your idea sounds promising, if I can get the old joint apart on the other side of the wall without damaging it. How did you fit the new plastic pipe into the old joint? -- James |
#19
Posted to uk.d-i-y
|
|||
|
|||
Soil pipe -- to replace or not to replace
On 04/07/2012 13:26, James wrote:
On 2012-07-03 21:16:27 +0000, newshound said: Looks a bit like an iron waste pipe to me; don't recognise the collar at all. What happens outside? One option might be to fit a new plastic pipe through the wall to an existing iron stack outside (which is what I have). Then you can have nice modern unbodged pipework inside the house. Thanks for the reply. I've just posted links to another couple of pictures of the outside -- see my reply to Adam. Your idea sounds promising, if I can get the old joint apart on the other side of the wall without damaging it. How did you fit the new plastic pipe into the old joint? In my case, I only replaced the vertical "vent" pipe (previous owner had replaced the angled one carrying fluid). As I recall, once I had removed all the old iron (a bit fiddly as you don't want to crack the junction) the new pipe "bottomed" on a step in the collar, which makes it fairly easy. Pack the bottom part of the joint with something like newspaper, string, baler twine, rope, etc and create a seal using suitable mastic or silicone. You can finish off the top with silicone, mastic, or even a cement filet. Since it never really sees positive pressure (even if there is stuff flowing down) the seal does not have to be brilliant. |
#20
Posted to uk.d-i-y
|
|||
|
|||
Soil pipe -- to replace or not to replace
James wrote:
On 2012-07-03 21:16:27 +0000, newshound said: Looks a bit like an iron waste pipe to me; don't recognise the collar at all. What happens outside? One option might be to fit a new plastic pipe through the wall to an existing iron stack outside (which is what I have). Then you can have nice modern unbodged pipework inside the house. Thanks for the reply. I've just posted links to another couple of pictures of the outside -- see my reply to Adam. Your idea sounds promising, if I can get the old joint apart on the other side of the wall without damaging it. How did you fit the new plastic pipe into the old joint? http://s428.photobucket.com/albums/q...t=100_0642.jpg http://s428.photobucket.com/albums/q...t=100_0641.jpg But it was lead I joined into:-( -- Adam |
#21
Posted to uk.d-i-y
|
|||
|
|||
Soil pipe -- to replace or not to replace
On 04/07/2012 13:26, James wrote:
On 2012-07-03 21:16:27 +0000, newshound said: Looks a bit like an iron waste pipe to me; don't recognise the collar at all. What happens outside? One option might be to fit a new plastic pipe through the wall to an existing iron stack outside (which is what I have). Then you can have nice modern unbodged pipework inside the house. Thanks for the reply. I've just posted links to another couple of pictures of the outside -- see my reply to Adam. Your idea sounds promising, if I can get the old joint apart on the other side of the wall without damaging it. How did you fit the new plastic pipe into the old joint? Personally I'd remove right back to the stack, including the tee. You could put plastic into the existing flange and pack it or buy a plastic to cast-iron adapter (I'd assume that even if yours is asbestos, it'd still be a similar size). SteveW |
#22
Posted to uk.d-i-y
|
|||
|
|||
Soil pipe -- to replace or not to replace
James wrote:
Hello -- first post here after reading for a long time and picking up lots of valuable advice. I'm going to completely replace our bathroom over the next few weeks. Before doing anything internally I was planning to replace the soil stack. The connection to the toilet is a mess -- years of bodging and putty and a cheap loo that wobbles and leaks because it hasn't been screwed to the wall. Here's a picture. Note that I didn't install this! http://tinypic.com/r/250htp1/6 But... now I find myself thinking how much easier it would be if I didn't have to get rid of the whole thing. The external pipework is old but sound. I don't want to fit a new toilet to a knackered pipe -- but does anyone have any thoughts about reusing what's there already? If I could saw/grind off the collar on the pipe and clean up the end then would a flexible pan connector make a decent seal? Would it help to use a long connector and push it further down the pipe than normal? The current (badly fitted) toilet is on a wooden plinth which will come out before the new toilet goes in. Is there likely to be a problem with the angle of the connector? Clearly the new one will need to be closer to the wall so it can be fixed in place. I'd rather not have to have a bit of wood between the back of the cistern and the wall. Any advice would be much appreciated. Two small children in the house mean that the quicker I can finish the project the better -- but if I'm going to have to bite the bullet and replace the whole thing then I might as well get on with it. Thanks in advance. James i've cut one vertical back to the floor and fitted a 90 degree univesral to it But it was brand new and unencrusted -- To people who know nothing, anything is possible. To people who know too much, it is a sad fact that they know how little is really possible - and how hard it is to achieve it. |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
How to replace water pipe | Home Repair | |||
How to replace water pipe | Home Repair | |||
More soil stacks - replace with hepvo? | UK diy | |||
Replace soil stack/stench pipe with AAV | UK diy | |||
Can I replace my own sewer pipe? | Home Repair |