  #1   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 2,688
Default short lengths of singles for conduit

Anyone know where I can get short lengths of 4mm^2 singles (brown, blue, green/yellow) for use in conduit ? I only need about 2 metres of each. I cannot find anywhere that does cut lengths.
B&Q used to have if on a roll years ago, but no longer.
I can run some TWE through but its much easier at the other end (an external socket) with singles.

Thanks,
Simon.
  #2   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 3,155
Default short lengths of singles for conduit

In article
10544532.543.1334365102539.JavaMail.geo-discussion-forums@vbue17,
sm_jamieson wrote:
Anyone know where I can get short lengths of 4mm^2 singles (brown, blue,
green/yellow) for use in conduit ? I only need about 2 metres of each. I
cannot find anywhere that does cut lengths. B&Q used to have if on a roll
years ago, but no longer. I can run some TWE through but its much easier
at the other end (an external socket) with singles.


TLC only do 6mm upwards. Why not strip the sheath off some T&E and put
sleeving over teh earth?

--
From KT24

Using a RISC OS computer running v5.18

  #3   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 2,688
Default short lengths of singles for conduit

On Saturday, April 14, 2012 8:21:47 AM UTC+1, charles wrote:
In article
10544532.543.1334365102539.JavaMail.geo-discussion-forums@vbue17,
sm_jamieson wrote:
Anyone know where I can get short lengths of 4mm^2 singles (brown, blue,
green/yellow) for use in conduit ? I only need about 2 metres of each. I
cannot find anywhere that does cut lengths. B&Q used to have if on a roll
years ago, but no longer. I can run some TWE through but its much easier
at the other end (an external socket) with singles.


TLC only do 6mm upwards. Why not strip the sheath off some T&E and put
sleeving over teh earth?

--
From KT24

Using a RISC OS computer running v5.18


Is it OK to use stripped TWE inside conduit ?
I assumed the insulation had to be thicker on singles without a second outside jacket ?
Simon.
  #4   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 7,688
Default short lengths of singles for conduit

sm_jamieson wrote:
On Saturday, April 14, 2012 8:21:47 AM UTC+1, charles wrote:
In article
10544532.543.1334365102539.JavaMail.geo-discussion-forums@vbue17,
sm_jamieson wrote:
Anyone know where I can get short lengths of 4mm^2 singles
(brown, blue, green/yellow) for use in conduit ? I only need
about 2 metres of each. I cannot find anywhere that does cut
lengths. B&Q used to have if on a roll years ago, but no longer.
I can run some TWE through but its much easier at the other end
(an external socket) with singles.


TLC only do 6mm upwards. Why not strip the sheath off some T&E and
put sleeving over teh earth?

--
From KT24

Using a RISC OS computer running v5.18


Is it OK to use stripped TWE inside conduit ?


Yes

I assumed the insulation had to be thicker on singles without a
second outside jacket ?


It's the same stuff. Just not wrapped in grey PVC:-)

--
Adam


  #5   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 2,688
Default short lengths of singles for conduit

On Saturday, April 14, 2012 9:17:58 AM UTC+1, wrote:
sm_jamieson wrote:
On Saturday, April 14, 2012 8:21:47 AM UTC+1, charles wrote:
In article
10544532.543.1334365102539.JavaMail.geo-discussion-forums@vbue17,
sm_jamieson wrote:
Anyone know where I can get short lengths of 4mm^2 singles
(brown, blue, green/yellow) for use in conduit ? I only need
about 2 metres of each. I cannot find anywhere that does cut
lengths. B&Q used to have if on a roll years ago, but no longer.
I can run some TWE through but its much easier at the other end
(an external socket) with singles.

TLC only do 6mm upwards. Why not strip the sheath off some T&E and
put sleeving over teh earth?

--
From KT24

Using a RISC OS computer running v5.18


Is it OK to use stripped TWE inside conduit ?


Yes

I assumed the insulation had to be thicker on singles without a
second outside jacket ?


It's the same stuff. Just not wrapped in grey PVC:-)

--
Adam


Thanks.


  #6   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 25,191
Default short lengths of singles for conduit

On 14/04/2012 08:50, sm_jamieson wrote:
On Saturday, April 14, 2012 8:21:47 AM UTC+1, charles wrote:
In article
10544532.543.1334365102539.JavaMail.geo-discussion-forums@vbue17,
wrote:
Anyone know where I can get short lengths of 4mm^2 singles (brown, blue,
green/yellow) for use in conduit ? I only need about 2 metres of each. I
cannot find anywhere that does cut lengths. B&Q used to have if on a roll
years ago, but no longer. I can run some TWE through but its much easier
at the other end (an external socket) with singles.


TLC only do 6mm upwards. Why not strip the sheath off some T&E and put
sleeving over teh earth?

--
From KT24

Using a RISC OS computer running v5.18


Is it OK to use stripped TWE inside conduit ?
I assumed the insulation had to be thicker on singles without a second outside jacket ?


That's where the conduit comes in ;-)


--
Cheers,

John.

/================================================== ===============\
| Internode Ltd - http://www.internode.co.uk |
|-----------------------------------------------------------------|
| John Rumm - john(at)internode(dot)co(dot)uk |
\================================================= ================/
  #7   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 2,688
Default short lengths of singles for conduit

On Saturday, April 14, 2012 2:49:51 PM UTC+1, John Rumm wrote:
On 14/04/2012 08:50, sm_jamieson wrote:
On Saturday, April 14, 2012 8:21:47 AM UTC+1, charles wrote:
In article
10544532.543.1334365102539.JavaMail.geo-discussion-forums@vbue17,
wrote:
Anyone know where I can get short lengths of 4mm^2 singles (brown, blue,
green/yellow) for use in conduit ? I only need about 2 metres of each. I
cannot find anywhere that does cut lengths. B&Q used to have if on a roll
years ago, but no longer. I can run some TWE through but its much easier
at the other end (an external socket) with singles.

TLC only do 6mm upwards. Why not strip the sheath off some T&E and put
sleeving over teh earth?

--
From KT24

Using a RISC OS computer running v5.18


Is it OK to use stripped TWE inside conduit ?
I assumed the insulation had to be thicker on singles without a second outside jacket ?


That's where the conduit comes in ;-)



I was now going to say, "I thought ..." and "I realise that ...", but its time to shut up !

Thanks guys,
Simon.
  #8   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 7,688
Default short lengths of singles for conduit

sm_jamieson wrote:
On Saturday, April 14, 2012 2:49:51 PM UTC+1, John Rumm wrote:
On 14/04/2012 08:50, sm_jamieson wrote:
On Saturday, April 14, 2012 8:21:47 AM UTC+1, charles wrote:
In article
10544532.543.1334365102539.JavaMail.geo-discussion-forums@vbue17,
wrote:
Anyone know where I can get short lengths of 4mm^2 singles
(brown, blue, green/yellow) for use in conduit ? I only need
about 2 metres of each. I cannot find anywhere that does cut
lengths. B&Q used to have if on a roll years ago, but no
longer. I can run some TWE through but its much easier at the
other end (an external socket) with singles.

TLC only do 6mm upwards. Why not strip the sheath off some T&E
and put sleeving over teh earth?

--
From KT24

Using a RISC OS computer running v5.18

Is it OK to use stripped TWE inside conduit ?
I assumed the insulation had to be thicker on singles without a
second outside jacket ?


That's where the conduit comes in ;-)



I was now going to say, "I thought ..." and "I realise that ...", but
its time to shut up !


It would be better if you used some 6491X cable for the earth and not the
earth from the T&E with earth sleeving over it.

--
Adam


Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Earth bonding - can I crimp short lengths? Lobster UK diy 24 December 8th 12 10:39 AM
singles through conduit to outside sm_jamieson UK diy 1 April 7th 12 08:00 AM
1/2" shank pattern bits with short cutting lengths? Mark[_16_] Woodworking 13 April 11th 08 08:34 PM
Romex in SHORT run of conduit? HerHusband Home Repair 22 June 15th 05 07:59 PM
Where to get short lengths 4 conductor wire Chris W Electronics 4 March 8th 05 10:41 PM


All times are GMT +1. The time now is 01:33 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"