CM Zone kicks in even with the reads set to off
I posted to automated homes, but thought I would ask here too.
The HC60NG has decided to cycle 6 times an hour (it should not be firing at all, and that's more than the 3 cph that I have configured it). You can set your watch with it, it fires at xx:y8:55 and it lasts 90 seconds (though minimum on time is set to 3 mins). That's with the CM67z set to OFF and also with its usual, low set-points (14 and 13.5). Things I tried: - Checked rads; other than the bypass (no HR80UK) all cold. - Pressed HC60NG button for 15 seconds, then again for 5 and synced with the CM67z; the red light went off and the boiler kicked in. - Checked the CM67z parameters, in particular: . 7:PE 0 (disabled) . 15:OP 0 (used to be enabled and I had no probs; disabling did not fix it) . 16:LC 0 (relay OFF) . 17:SU (actually 13:SU in my case): 0 (HR80UK enabled) and 2 (both HR80UK and HC60NG enabled) made no difference; 0 is my usual. - 6:tS is 2 (enabled for display and control) I will try to go around the house and remove the batteries from the HR80UKs to see if I can eliminate it. Any thought on how to address the dreaded problem will be most appreciated. Thanks, Kostas -- Emails to this address are dropped. |
#2
Posted to uk.d-i-y
|
|||
|
|||
CM Zone kicks in even with the reads set to off
On 17/09/2011 13:16, Kostas Kavoussanakis wrote:
I posted to automated homes, but thought I would ask here too. The HC60NG has decided to cycle 6 times an hour (it should not be firing at all, and that's more than the 3 cph that I have configured it). You can set your watch with it, it fires at xx:y8:55 and it lasts 90 seconds (though minimum on time is set to 3 mins). That's with the CM67z set to OFF and also with its usual, low set-points (14 and 13.5). Things I tried: - Checked rads; other than the bypass (no HR80UK) all cold. - Pressed HC60NG button for 15 seconds, then again for 5 and synced with the CM67z; the red light went off and the boiler kicked in. - Checked the CM67z parameters, in particular: . 7:PE 0 (disabled) . 15:OP 0 (used to be enabled and I had no probs; disabling did not fix it) . 16:LC 0 (relay OFF) . 17:SU (actually 13:SU in my case): 0 (HR80UK enabled) and 2 (both HR80UK and HC60NG enabled) made no difference; 0 is my usual. - 6:tS is 2 (enabled for display and control) I will try to go around the house and remove the batteries from the HR80UKs to see if I can eliminate it. Any thought on how to address the dreaded problem will be most appreciated. Caught it: HR80UK was not seated properly. Kostas -- Emails to this address are dropped. |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Drive reads CD but not DVD | Electronics Repair | |||
Nice Reads | Home Repair | |||
OT Who reads this forum? | Home Repair | |||
thermostat compatibility for 2 zone hot water heating w/o zone valves | Home Ownership |