Hello there,

I have a conventional boiler and an indirect hot water cylinder with a heat
exchanger. Rads are heating up fine - water runs from the hot water tap but
it is cold - from reading around I think I either have an airlock in the
coil inside the tank or a faulty motorised valve. Anyway of differentiating
between the two ?

If it is an airlock should I just drain the whole system and refill ? Are
the any other ways ?
Where is the motorised valve for determining whether I get HW+CH or just HW
?

Any help appreciated - my little 'un wants a bath !

Regards

Chris


---
Outgoing mail is certified Virus Free.
Checked by AVG anti-virus system (http://www.grisoft.com).
Version: 6.0.535 / Virus Database: 330 - Release Date: 1/11/03


  #2   Report Post  
Jonathan Curtis
 
Posts: n/a
Default Airlock in heat exchanger ?

"Bolton" wrote in message


Hello there,

I have a conventional boiler and an indirect hot water cylinder with a heat
exchanger. Rads are heating up fine - water runs from the hot water tap but
it is cold - from reading around I think I either have an airlock in the
coil inside the tank or a faulty motorised valve. Anyway of differentiating
between the two ?

If it is an airlock should I just drain the whole system and refill ? Are
the any other ways ?
Where is the motorised valve for determining whether I get HW+CH or just HW
?

Any help appreciated - my little 'un wants a bath !

Regards



If it's an airlock you could tell by opening the nut to the cylinder
(from the boiler) slowly and carefully the air should come out with
considerable force after only one or two turns.
You probably need to fit an automatic air vent on the top of this pipe
to the cylinder or a "finger vent"(if there isn't one already fitted)
which you use to fill it manually.
If no air lock then you'll have to ignore the above and find the
motorized valves.
They are usually somewhere near the pump switch the black lever from
auto to manual
and see if it makes a difference. It's a good idea to fit an immersion
heater
for these eventuallities.

Jon




Chris


---
Outgoing mail is certified Virus Free.
Checked by AVG anti-virus system (http://www.grisoft.com).
Version: 6.0.535 / Virus Database: 330 - Release Date: 1/11/03





--
Posted via Mailgate.ORG Server - http://www.Mailgate.ORG
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
gas boiler thermocouple Stoney UK diy 56 October 20th 03 09:02 PM
Hot water system PJO UK diy 44 October 7th 03 01:11 PM
I want to use my fireplace as the primary room heat source - using gas! - How? Jo UK diy 2 July 24th 03 06:10 PM
heat exchanger calculations Ed Sirett UK diy 2 July 19th 03 12:49 AM
heat exchanger design calculations [repost] John Stumbles UK diy 6 July 17th 03 02:57 PM


All times are GMT +1. The time now is 08:48 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"