Home |
Search |
Today's Posts |
![]() |
|
UK diy (uk.d-i-y) For the discussion of all topics related to diy (do-it-yourself) in the UK. All levels of experience and proficency are welcome to join in to ask questions or offer solutions. |
Reply |
|
LinkBack | Thread Tools | Display Modes |
|
#1
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
On Jun 7, 11:51*am, Tabby wrote:
On Jun 7, 6:28*am, harry wrote: On Jun 6, 6:35*pm, Tabby wrote: On Jun 6, 6:24*pm, harry wrote: On Jun 6, 1:18*pm, (Andrew Gabriel) wrote: Just fitted a TRV (Drayton TRV4) to a radiator on a single pipe system, partly as an experiment (if it works, there are about another 6 to do). However, it seems not to work. The flow restriction through it when fully open is too much resistance to get enough flow through the radiator, resulting in a hot area along the radiator top only.. I might try moving the inlet to the top so the hydrostatic pressure difference between the hot and cooling water helps the flow, but I'm not hopeful this will make enough differemce to notice. Just wondering if anyone has come across any suitable product for a single pipe system? -- Andrew Gabriel [email address is not usable -- followup in the newsgroup] There were special TRVs for single pipe systems. It has much larger valve body. There is no way you will get a two pipe system TRV to work here. I have had a look, no-one seems to be making anything anymore. Your best bet is to get a motorised valve to control the circuit. The pressure drop across the rad depends on the type of tees. There are plain tees, swept tees and cup tees in ascending order of preference. Why not just restrict the flow in the shorting pipe more? With an adjustable valve. NT- Hide quoted text - - Show quoted text - This would prevent the whole system from working! how on earth would adding a little more restriction do that? NT- Hide quoted text - - Show quoted text - The pumps are very low head/pressure on a single pipe system (Resistance is low the pipe is of quite large diameter with no obsructions.) If you throttled any part of the single pipe it would affect all the radiators. |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Problem changing 1-pipe CH system to 2-pipe system | UK diy | |||
Using a Condensing Boiler with a Single Pipe Radiator System | UK diy | |||
Single pipe series connected radiators | UK diy | |||
Is there a single lockshield valve on old CH system? | UK diy | |||
single pipe central heating | UK diy |