My 1988 house has the C/H pipes behind the plasterboard. I have a concern
that one radiator is not getting hot and have discovered a restricted flow
from one of the pipes. (8mm)

If I need a pipe replacing when I have a new boiler how easy is it to have a
strip of PB removed and then replaced over one of the drops from the
ceiling? Somehow it doesn't seem right just to cover with plaster.


  #2   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 4,555
Default Pipes behind plasterboard

John wrote:
My 1988 house has the C/H pipes behind the plasterboard. I have a concern
that one radiator is not getting hot and have discovered a restricted flow
from one of the pipes. (8mm)

If I need a pipe replacing when I have a new boiler how easy is it to have a
strip of PB removed and then replaced over one of the drops from the
ceiling? Somehow it doesn't seem right just to cover with plaster.


The simple answer is that in principle it'd straightforward enough to
do; from the wording of your query it doesn't sound like you'd be
diy'ing it?

Dependinf what needs replacing and exactly where it is, you might get
well away with removing and repairing patches, rather than a whole
'strip', ie poking the new pipe through as required.

However, are you sure this is actually necessary? Why do you think the
flow in this pipe is 'restricted'? Even if it is, unblocking it is
probably the way forward.

David
  #3   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 6,938
Default Pipes behind plasterboard

In message , John
writes
My 1988 house has the C/H pipes behind the plasterboard. I have a concern
that one radiator is not getting hot and have discovered a restricted flow
from one of the pipes. (8mm)


Check the TRV before engaging in major surgery. I have two *sticky* ones
in a 15 year old installation. Top unscrews to reveal a small plunger.
One day, I am going to ask in here if any sort of lubrication is likely
to help:-)

regards

--
Tim Lamb
  #4   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 1,835
Default Pipes behind plasterboard


"Tim Lamb" wrote in message
...
In message , John
writes
My 1988 house has the C/H pipes behind the plasterboard. I have a concern
that one radiator is not getting hot and have discovered a restricted flow
from one of the pipes. (8mm)


Check the TRV before engaging in major surgery. I have two *sticky* ones
in a 15 year old installation. Top unscrews to reveal a small plunger. One
day, I am going to ask in here if any sort of lubrication is likely to
help:-)

regards

--
Tim Lamb


I don't have TRVs.

The system is due for a new boiler and whilst I won't be DIYing it - I like
to know what should be done or what could be done. I don't want a plumber
'selling me' plastic trunking down the wall..

I have removed the valve (Twin entry and this confirmed a very restricted
flow down the return pipe. The radiator is slow to heat up - I tried
backflushing with a mains hose pipe attached but couldn't get an
improvement. I am thinking a new pipe back to the manifold might be the best
solution. (By the way - why have I never seen manifolds in plumbers
merchants?)


  #5   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 744
Default Pipes behind plasterboard

On Feb 18, 9:23 am, "John" wrote:
"Tim Lamb" wrote in message

...

In message , John
writes
My 1988 house has the C/H pipes behind the plasterboard. I have a concern
that one radiator is not getting hot and have discovered a restricted flow
from one of the pipes. (8mm)


Check the TRV before engaging in major surgery. I have two *sticky* ones
in a 15 year old installation. Top unscrews to reveal a small plunger. One
day, I am going to ask in here if any sort of lubrication is likely to
help:-)


regards


--
Tim Lamb


I don't have TRVs.

The system is due for a new boiler and whilst I won't be DIYing it - I like
to know what should be done or what could be done. I don't want a plumber
'selling me' plastic trunking down the wall..

I have removed the valve (Twin entry and this confirmed a very restricted
flow down the return pipe. The radiator is slow to heat up - I tried
backflushing with a mains hose pipe attached but couldn't get an
improvement. I am thinking a new pipe back to the manifold might be the best
solution. (By the way - why have I never seen manifolds in plumbers
merchants?)


cos they are in the stock room?

JimK
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Can you get flexible gutter pipes/underground pipes? eden UK diy 8 June 25th 09 04:45 PM
Plasterboard norm UK diy 6 January 17th 06 10:24 AM
Plastic pipes v copper pipes! Vikki UK diy 11 November 26th 05 03:44 PM
Freezing Pipes or Pipes frozen could the Instant Hot Water Recirculator from RedyTemp work [email protected] Home Repair 1 January 11th 04 12:18 PM
Where to buy plasterboard? Bob Eager UK diy 11 December 13th 03 12:02 AM


All times are GMT +1. The time now is 04:24 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"