Hello,
I need to replace the adjusters on the back of some wall hung cupboards and shelves (actually Tapley units). The adjusters are a two part item on the bottom edge of the shelf/cupboard. The outer part has about a 3/8 inch diameter shallow thread to go into the chipboard/mdf etc edge and the inner part threads into this with a large(ish) 3/4 inch diameter flat plat that pushes against the wall to move the whole lower edge of the shelf to achieve accurate front to back horizontal adjustment of the whole unit. Any suggestions please as to where I can obtain such? Regards, Colin -- Colin Brook - Winchester (UK) Fax:+44(0)8701641293 Mobile:07976258703 |
#2
Posted to uk.d-i-y
|
|||
|
|||
Wall hung cupboard adjusters
Colin Brook wrote:
Hello, I need to replace the adjusters on the back of some wall hung cupboards and shelves (actually Tapley units). The adjusters are a two part item on the bottom edge of the shelf/cupboard. The outer part has about a 3/8 inch diameter shallow thread to go into the chipboard/mdf etc edge and the inner part threads into this with a large(ish) 3/4 inch diameter flat plat that pushes against the wall to move the whole lower edge of the shelf to achieve accurate front to back horizontal adjustment of the whole unit. Any suggestions please as to where I can obtain such? Regards, Colin Sorry - don't really follow your description - a photo would have helped. Maybe something like this would help? http://www.isaaclord.co.uk/productDetail.aspx?product=464&subCat=000 If so, a) make sure you get the wall plates if required; b) you need a right and a left; c) -- Rod Hypothyroidism is a seriously debilitating condition with an insidious onset. Although common it frequently goes undiagnosed. www.thyromind.info www.thyroiduk.org www.altsupportthyroid.org |
#3
Posted to uk.d-i-y
|
|||
|
|||
Wall hung cupboard adjusters
Colin Brook wrote: I need to replace the adjusters on the back of some wall hung cupboards and shelves (actually Tapley units). The adjusters are a two part item on the bottom edge of the shelf/cupboard. The outer part has about a 3/8 inch diameter shallow thread to go into the chipboard/mdf etc edge and the inner part threads into this with a large(ish) 3/4 inch diameter flat plat that pushes against the wall to move the whole lower edge of the shelf to achieve accurate front to back horizontal adjustment of the whole unit. Any suggestions please as to where I can obtain such? Which part has broken? The threaded part that goes into the wood could be replaced with a nutsert for wood (http://www.nutserts.co.uk/) The bolt part that holds the bottom of the cabinet away from the wall is a plastic-headed screw. If you can't get, say, a suitable nylon screw, would a suitable alternative be a steel one with a plastic screw-cap glued on? It's not readily visible. The only time I've had to replace a Tapley fitting (hinges), they were provided at no charge by Beaver & Tapley. Pehaps contacting them directly will gain access to their spares department? Their contact details are available via Google, assuming they're still trading... -- John W To mail me replace the obvious with co.uk twice |
#4
Posted to uk.d-i-y
|
|||
|
|||
Wall hung cupboard adjusters
In message on Sat, 14 Mar
2009, John Weston wrote Any suggestions please as to where I can obtain such? Which part has broken? The threaded part that goes into the wood could be replaced with a nutsert for wood (http://www.nutserts.co.uk/) The bolt part that holds the bottom of the cabinet away from the wall is a plastic-headed screw. If you can't get, say, a suitable nylon screw, would a suitable alternative be a steel one with a plastic screw-cap glued on? It's not readily visible. The only time I've had to replace a Tapley fitting (hinges), they were provided at no charge by Beaver & Tapley. Pehaps contacting them directly will gain access to their spares department? Their contact details are available via Google, assuming they're still trading... Thanks for that - the nutserts will provide what I want I think. I'll try Tapley but these days they don't seem very responsive. Thanks again, Colin -- Colin Brook - Winchester (UK) Fax:+44(0)8701641293 Mobile:07976258703 |
#5
Posted to uk.d-i-y
|
|||
|
|||
Wall hung cupboard adjusters
In message on Fri, 13 Mar 2009, Rod
wrote Colin Brook wrote: Hello, I need to replace the adjusters on the back of some wall hung cupboards and shelves (actually Tapley units). Sorry - don't really follow your description - a photo would have helped. Maybe something like this would help? Sorry Rod, I realised it wasn't easy to follow but the nutserts (http://www.nutserts.co.uk/) that John has identified is what I'm looking for. Thanks for help. Colin -- Colin Brook - Winchester (UK) Fax:+44(0)8701641293 Mobile:07976258703 |
Reply |