Earthing for a Multiswitch
I'm considering using a (Triax 5 x 8) multiswitch to distribute TV/satellite
round the house. I've read that multiswitches must be earthed directly back to the CU. But I've also seen some comments that this isn't necessary for a normal domestic installation where power to the building is supplied on a single phase - which is my situation. Can anyone give the current requirements? Thanks. |
#2
Posted to uk.d-i-y
|
|||
|
|||
Earthing for a Multiswitch
On Tue, 13 Jan 2009 15:25:04 -0000, Steve wrote:
I've read that multiswitches must be earthed directly back to the CU. But I've also seen some comments that this isn't necessary for a normal domestic installation where power to the building is supplied on a single phase - which is my situation. Is Bill Wright in here? I'd bond all the screens at the multiswitch with the appropiate earthing block. I may not take a proper bond from that all the way back to the CU supply earth, just use the CPC of the multiswitch supply assuming that was a direct feed from the CU or off a ring and fed with 2.5mm. If the multiswitch supply was of the lighting circuit I'd not use that CPC, it's lighter weight and not a ring. -- Cheers Dave. |
#3
Posted to uk.d-i-y
|
|||
|
|||
Earthing for a Multiswitch
In article ,
Steve wrote: I'm considering using a (Triax 5 x 8) multiswitch to distribute TV/satellite round the house. I've read that multiswitches must be earthed directly back to the CU. But I've also seen some comments that this isn't necessary for a normal domestic installation where power to the building is supplied on a single phase - which is my situation. Can anyone give the current requirements? Thanks. Pretty certain this is only for communal systems in blocks of flats, etc. -- *We waste time, so you don't have to * Dave Plowman London SW To e-mail, change noise into sound. |
#4
Posted to uk.d-i-y
|
|||
|
|||
Earthing for a Multiswitch
Steve has brought this to us :
I'm considering using a (Triax 5 x 8) multiswitch to distribute TV/satellite round the house. I've read that multiswitches must be earthed directly back to the CU. But I've also seen some comments that this isn't necessary for a normal domestic installation where power to the building is supplied on a single phase - which is my situation. Can anyone give the current requirements? Thanks. I would guess that earthing via the mains supply, from the socket it is supplied from would be perfectly adequate for the purpose. -- Regards, Harry (M1BYT) (L) http://www.ukradioamateur.co.uk |
#5
Posted to uk.d-i-y
|
|||
|
|||
Earthing for a Multiswitch
On Tue, 13 Jan 2009 15:25:04 -0000 someone who may be "Steve"
wrote this:- I'm considering using a (Triax 5 x 8) multiswitch to distribute TV/satellite round the house. Antiference have a good reputation, for example http://www.tvaerials.com/product.aspx?productid=1925. See http://www.antiference.tv/products/distribution for further details. I've read that multiswitches must be earthed directly back to the CU. But I've also seen some comments that this isn't necessary for a normal domestic installation where power to the building is supplied on a single phase - which is my situation. A television aerial connected to a lead which runs down the side of a house and through a window frame to a socket or flying lead is a somewhat different proposition to a distribution system with cables snaking to most rooms in the house, various aerials/dishes and a powered amplifier. There is also the question of what the situation is when part of the distribution system is removed, particularly in a block of flats. In a block of flats the cables should be earthed. As well as protecting occupants this also protects the distribution system installer from dodgy wiring in flats. That means using an earthing bar or something like http://www.antiference.tv/earthlink. Remove the multiswitch, or other part of the system and earthing is still provided. In a single house the issue is less clear cut. I'm not convinced earthing bars and the like are necessary, but proper earthing is. There is usually an earthing terminal on the multiswitch. I largely agree with the other posting on what this should be connected to. -- David Hansen, Edinburgh I will *always* explain revoked encryption keys, unless RIP prevents me http://www.opsi.gov.uk/acts/acts2000/00023--e.htm#54 |
#6
Posted to uk.d-i-y
|
|||
|
|||
Earthing for a Multiswitch
Steve" wrote in message
... I'm considering using a (Triax 5 x 8) multiswitch to distribute TV/satellite round the house. I've read that multiswitches must be earthed directly back to the CU. But I've also seen some comments that this isn't necessary for a normal domestic installation where power to the building is supplied on a single phase - which is my situation. Can anyone give the current requirements? Thanks. Thanks chaps. I'll just use the mains CPC. Steve. |