Default Combi boiler problem

It's that time of year I suppose, although this one is about the hot
water, not the heating.

It's an Ariston Microgenus. It seems to have developed an intermittent
fault whereby sometimes when you turn on a tap the hot water just
doesn't get hot. While the hot tap is running there seems to be a lot
of churning coming from the boiler, which I assume is the pump
running, but neither the fan nor the burners come on. The "fume
sensor" LED comes on until you turn the tap off, whereupon the light
goes out again. This fume sensor LED seems to be a mystery from the
research I've done. The manual doesn't say what exactly it senses. And
I don't see how it can be sensing "fumes" because the burners aren't
lit!

Any immediate ideas as to what would cause this to happen
intermittently?

Cheers!

Martin
  #2   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 1,307
Default Combi boiler problem

Martin Pentreath wrote:

It's that time of year I suppose, although this one is about the hot
water, not the heating.

It's an Ariston Microgenus. It seems to have developed an intermittent
fault whereby sometimes when you turn on a tap the hot water just
doesn't get hot. While the hot tap is running there seems to be a lot
of churning coming from the boiler, which I assume is the pump
running, but neither the fan nor the burners come on. The "fume
sensor" LED comes on until you turn the tap off, whereupon the light
goes out again. This fume sensor LED seems to be a mystery from the
research I've done. The manual doesn't say what exactly it senses. And
I don't see how it can be sensing "fumes" because the burners aren't
lit!


Has it got a pressurised container?
If so, is the pressure high enough in the pressure vessel?
I ask, as I had a similar problem with a Baxi a few months ago, I had
drained all the water out to fit new rads, on refilling, the air
pressure had all gone, so although the pressure gauge said it was fine,
there was not enough air in it to allow the boiler to turn on for more
than 10 seconds. It also made an awful lot of gurgling sounds as of
there was a lot of air in the boiler.
After a drain off of a few litres, then re-pressurise the vessel with a
car pump, all was fine.
Alan.

--
To reply by e-mail, change the ' + ' to 'plus'.
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
combi boiler problem Gilbert[_2_] UK diy 5 October 20th 07 04:26 PM
Combi boiler - problem. [email protected] UK diy 16 November 1st 06 09:26 PM
Combi boiler - problem. matphil Home Repair 3 October 29th 06 05:55 PM
Combi Boiler Problem [email protected] UK diy 3 July 5th 06 08:35 PM
Another combi boiler problem DaveŁ UK diy 7 October 18th 04 05:20 PM


All times are GMT +1. The time now is 12:48 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"