Electrical inspection certificate technical question
My domestic test report schedule has Z (e) at origin of 0.17 ohms.
For one of the circuits continuity R2 ohms is 0.66 and Earth Loop impedence Z (s) is 1.31. Another electrician says that there should be a relationship where the 1.31 number minus the 0.17 number should give the 0.66 result - but this equation is not giving the right result. Is there a reason for the discrepancy. Also for an immersion heater circuit the certificate has R2 as 0.01 and Z (s) as 0.41. The second electician says that the 0.01 would be correct only if the heater was right next to the fuse box - its actually at least 15 foot away. I dont know who is correct. TIA Thomas. |