blocks below ground level
My plans have inner skin of thermalite blocks from foundation (3
courses down). All blocks below the floor level will of course have insulation against the floor slab. Is it OK regs wise, to start the inner skin in denser non-insulative blocks (bricks, concrete blocks etc) ? The build is a slow process and I don't fancy having thermalite down where water may pool for any length of time. Thanks, Simon. |
#2
Posted to uk.d-i-y
|
|||
|
|||
blocks below ground level
sm_jamieson wrote:
My plans have inner skin of thermalite blocks from foundation (3 courses down). All blocks below the floor level will of course have insulation against the floor slab. Is it OK regs wise, to start the inner skin in denser non-insulative blocks (bricks, concrete blocks etc) ? I would have said it was against bulding regs to *use* thermalite below DPC. The build is a slow process and I don't fancy having thermalite down where water may pool for any length of time. Damn right. Bloc/engineering brick up to DPC, then brick/cavty batts and thermalite above. Thanks, Simon. |
#3
Posted to uk.d-i-y
|
|||
|
|||
blocks below ground level
On Mar 10, 12:59*am, The Natural Philosopher wrote:
sm_jamieson wrote: My plans have inner skin of thermalite blocks from foundation (3 courses down). All blocks below the floor level will of course have insulation against the floor slab. Is it OK regs wise, to start the inner skin in denser non-insulative blocks (bricks, concrete blocks etc) ? I would have said it was against bulding regs to *use* thermalite below DPC. The build is a slow process and I don't fancy having thermalite down where water may pool for any length of time. Damn right. Bloc/engineering brick up to DPC, then brick/cavty batts and thermalite above. Thanks, Simon.- Hide quoted text - - Show quoted text - I was looking at a new housing site near me, and they were using what looked like lightweight 'Celcon' type blocks, about 300 mm wide, from below ground to DPC level. Then start cavity work, presumably. I assume, this is within current building regs., but surprises me a bit. Even without water ponding, cannot be good for these type of blocks to get damp. Mind you, on hol. in France, Vendee area on the coast, they were building house walls solely out of these blocks, 250 / 300 mm wide, then render. No cavities! |
#4
Posted to uk.d-i-y
|
|||
|
|||
blocks below ground level
On 9 Mar, 23:14, sm_jamieson wrote:
My plans have inner skin of thermalite blocks from foundation (3 courses down). All blocks below the floor level will of course have insulation against the floor slab. Is it OK regs wise, to start the inner skin in denser non-insulative blocks (bricks, concrete blocks etc) ? The build is a slow process and I don't fancy having thermalite down where water may pool for any length of time. Thanks, Simon. Look at the manufacturer's specs for whatever make of block you are using. Some type of aerated/lightweight blocks ARE classed as suitable for below ground. Phil. |
#5
Posted to uk.d-i-y
|
|||
|
|||
blocks below ground level
On 10 Mar, 00:59, The Natural Philosopher wrote:
sm_jamieson wrote: My plans have inner skin of thermalite blocks from foundation (3 courses down). All blocks below the floor level will of course have insulation against the floor slab. Is it OK regs wise, to start the inner skin in denser non-insulative blocks (bricks, concrete blocks etc) ? I would have said it was against bulding regs to *use* thermalite below DPC. The build is a slow process and I don't fancy having thermalite down where water may pool for any length of time. Damn right. Bloc/engineering brick up to DPC, then brick/cavty batts and thermalite above. Thanks, Simon. Good. its nice to see common sense actually makes sense this time ! Cheers, Simon. |
#6
Posted to uk.d-i-y
|
|||
|
|||
blocks below ground level
sm_jamieson wrote:
My plans have inner skin of thermalite blocks from foundation (3 courses down). All blocks below the floor level will of course have insulation against the floor slab. Is it OK regs wise, to start the inner skin in denser non-insulative blocks (bricks, concrete blocks etc) ? You can use concrete blocks, so long as they are solid IE, they don't have the hollowed out bit. concrete common bricks are the cheapest if you want to use these, engineers are a waste of money below ground as they far exceed the couple of newtons required The build is a slow process and I don't fancy having thermalite down where water may pool for any length of time. Most modern building are built on 300mm wide thermalite trench blocks - pretty much exactly the same as normal thermalite, but don't forget, they must stop at or below ground level and then a cavity wall is built up to DPC. They are used solely for speed - building what might be 5ft high walls below ground is no fun at all using bricks. |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Ground Level Deck Question s | Home Repair | |||
Ground level flooring advice needed | Home Repair | |||
basement window almost at ground level | Home Repair | |||
Rotting deck posts (below ground level) | Home Repair | |||
How to make level ground in the backyard? | Home Repair |