I moving the mains water entry point so that the 25 mm MDPE blue pipe
comes in near my kitchen sink rather than its present awkward location.

I've dug under the foundations (1850's end terrace) and put a new 25 mm MDPE
pipe in position.

The new location is approx. 6 feet away from the current and requires the
pipe to be extended so I'm using one of Screwfixs straight couplers.

Are there any precautions I should take since this connection will be
underground - I going to wrap pipe insulation around the pipe that is in
the outside trench.


Also, to make the copper connection inside I'm buying a 25 mm to 22 mm
copper adaptor set (page 196). How do these work?

Thank you,
Neil
  #2   Report Post  
John Woodhall
 
Posts: n/a
Default relocating mains water entry point


"Niel A. Farrow" wrote in message
...
I moving the mains water entry point so that the 25 mm MDPE blue pipe
comes in near my kitchen sink rather than its present awkward location.

I've dug under the foundations (1850's end terrace) and put a new 25 mm

MDPE
pipe in position.

The new location is approx. 6 feet away from the current and requires the
pipe to be extended so I'm using one of Screwfixs straight couplers.

Are there any precautions I should take since this connection will be
underground - I going to wrap pipe insulation around the pipe that is in
the outside trench.



AFAIK there is no need for this, if its deep enough then it should need no
insulation. It is fine to just bury it.



Also, to make the copper connection inside I'm buying a 25 mm to 22 mm
copper adaptor set (page 196). How do these work?



I got the screwfix adapter and found that it was fine. Many on this NG
though don`t like the ones from screwfix but I found it better than the all
singing all dancing one from Buy and Queue. You have to buy another 25mm
MDPE coupler from screwfix. When you get it, take one of the screw collars
off, (the outermost cover which tightens everything) and then take all the
gubbins out from one side. The adapter then sits into the coupling, push the
22mm copper in remembering to slip the screw collar onto it and tighten it
up. Make sure you do use the pipe inserts in the MDPE though or it will leak
eventually.

Regards

John



  #3   Report Post  
BigWallop
 
Posts: n/a
Default relocating mains water entry point


"John Woodhall" wrote in message
...

"Niel A. Farrow" wrote in message
...
I moving the mains water entry point so that the 25 mm MDPE blue pipe
comes in near my kitchen sink rather than its present awkward location.

I've dug under the foundations (1850's end terrace) and put a new 25 mm

MDPE
pipe in position.

The new location is approx. 6 feet away from the current and requires

the
pipe to be extended so I'm using one of Screwfixs straight couplers.

Are there any precautions I should take since this connection will be
underground - I going to wrap pipe insulation around the pipe that is in
the outside trench.



AFAIK there is no need for this, if its deep enough then it should need no
insulation. It is fine to just bury it.



Also, to make the copper connection inside I'm buying a 25 mm to 22 mm
copper adaptor set (page 196). How do these work?



I got the screwfix adapter and found that it was fine. Many on this NG
though don`t like the ones from screwfix but I found it better than the

all
singing all dancing one from Buy and Queue. You have to buy another 25mm
MDPE coupler from screwfix. When you get it, take one of the screw collars
off, (the outermost cover which tightens everything) and then take all the
gubbins out from one side. The adapter then sits into the coupling, push

the
22mm copper in remembering to slip the screw collar onto it and tighten it
up. Make sure you do use the pipe inserts in the MDPE though or it will

leak
eventually.

Regards

John




It's fine to just bury it, but because you've moved its position, it is a
good idea to put some warning tape about 200mm to 300mm above it and warn
people that the pipe is there and to be careful.


Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Condensing-combi boilers Sapient Fridge UK diy 16 September 23rd 03 01:27 PM
Mains water pressure issues. Peter UK diy 8 September 20th 03 02:10 PM
Megaflow Query Julia Mann UK diy 27 September 20th 03 09:34 AM
Knocking from hot water tank... Adam UK diy 7 September 4th 03 03:51 PM
mains Hot water, and do I convert open heating to a closed heating system Ian Tracey UK diy 5 July 18th 03 09:55 AM


All times are GMT +1. The time now is 03:43 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"