Loud banging from airing cupboard and crunching sound from radiators
Hello all
I hope someone can help me with this problem as it is starting to really annoy us. I leave the heating turned on at the timer in the airing cupboard and control the heating with the thermostat situated in the hall. After the heating has been on for a few hours (this is not constant) at approximately 20 Degrees C there is a very loud banging that sounds as if it is coming from the airing cupboard. There is also a kind of crunching sound that comes from the radiators even though they are warm. If I run the hot water tap for a few seconds then the banging will stop. I have tried to bleed the radiators using the key but there is little or no air in them. Is there anyway to get rid of air in the system easily without having to get a plumber in? I had thought about draining down the system but do not really know how to do this and also do not know if this would get rid of the air. Thanks in advance for any help you can provide. Kevin |
#2
Posted to uk.d-i-y
|
|||
|
|||
Loud banging from airing cupboard and crunching sound from radiators
"Kevin Cowans" wrote in message ... Hello all I hope someone can help me with this problem as it is starting to really annoy us. I leave the heating turned on at the timer in the airing cupboard and control the heating with the thermostat situated in the hall. After the heating has been on for a few hours (this is not constant) at approximately 20 Degrees C there is a very loud banging that sounds as if it is coming from the airing cupboard. There is also a kind of crunching sound that comes from the radiators even though they are warm. If I run the hot water tap for a few seconds then the banging will stop. I have tried to bleed the radiators using the key but there is little or no air in them. Is there anyway to get rid of air in the system easily without having to get a plumber in? I had thought about draining down the system but do not really know how to do this and also do not know if this would get rid of the air. Thanks in advance for any help you can provide. Kevin What type of boiler has your system got? It it a combi? Is there a hot water cylinder in the airing cupboard? It it a sealed system (with a pressure guage)? What pressure is it showing? We need more info... ----== Posted via Newsfeeds.Com - Unlimited-Unrestricted-Secure Usenet News==---- http://www.newsfeeds.com The #1 Newsgroup Service in the World! 120,000+ Newsgroups ----= East and West-Coast Server Farms - Total Privacy via Encryption =---- |
#3
Posted to uk.d-i-y
|
|||
|
|||
Loud banging from airing cupboard and crunching sound from radiators
"Kevin Cowans" wrote in message ... Hello all I hope someone can help me with this problem as it is starting to really annoy us. I leave the heating turned on at the timer in the airing cupboard and control the heating with the thermostat situated in the hall. After the heating has been on for a few hours (this is not constant) at approximately 20 Degrees C there is a very loud banging that sounds as if it is coming from the airing cupboard. There is also a kind of crunching sound that comes from the radiators even though they are warm. If I run the hot water tap for a few seconds then the banging will stop. It sound as though the water in the system is boiling and trying to vent. Perhaps the boiler thermostat is not operating properly or the boiler temperature is set too high. The noise could perhaps also be a zone valve sticking or trying to open/close. -- Dave Baker - Puma Race Engines |
#4
Posted to uk.d-i-y
|
|||
|
|||
Loud banging from airing cupboard and crunching sound from radiators
Kevin Cowans wrote:
After the heating has been on for a few hours (this is not constant) at approximately 20 Degrees C there is a very loud banging that sounds as if it is coming from the airing cupboard. There is also a kind of crunching sound that comes from the radiators even though they are warm. If I run the hot water tap for a few seconds then the banging will stop. I have tried to bleed the radiators using the key but there is little or no air in them. My heating system had symptoms like that - it seems that the plumber we had paid to (among other things) add anti-freeze to the system, had turned off the water to the expansion tank while doing the work, and had neglected to turn it back on when done. The tank was lidless - and about 18 months later, most of the water had evaporated. It was the middle of winter, my young daughter and I were alone, and it sounded like the system was about to explode!. After running the hot tap and turning off the heating, I checked the tank in the loft, saw it was empty, found the valve, which was carefully hidden by insulation, and turned it on. The tank now has a lid, and I called a different plumber the next time I needed work done.... |
#5
Posted to uk.d-i-y
|
|||
|
|||
Loud banging from airing cupboard and crunching sound from radiators
Hello Alan
What type of boiler has your system got? It it a combi? The boiler is a Maxol HomeWarm 600 (Combi). Is there a hot water cylinder in the airing cupboard? Yes It it a sealed system (with a pressure guage)? What pressure is it showing? No Hope this helps. Kevin "Alan" wrote in message ... "Kevin Cowans" wrote in message ... Hello all I hope someone can help me with this problem as it is starting to really annoy us. I leave the heating turned on at the timer in the airing cupboard and control the heating with the thermostat situated in the hall. After the heating has been on for a few hours (this is not constant) at approximately 20 Degrees C there is a very loud banging that sounds as if it is coming from the airing cupboard. There is also a kind of crunching sound that comes from the radiators even though they are warm. If I run the hot water tap for a few seconds then the banging will stop. I have tried to bleed the radiators using the key but there is little or no air in them. Is there anyway to get rid of air in the system easily without having to get a plumber in? I had thought about draining down the system but do not really know how to do this and also do not know if this would get rid of the air. Thanks in advance for any help you can provide. Kevin What type of boiler has your system got? It it a combi? Is there a hot water cylinder in the airing cupboard? It it a sealed system (with a pressure guage)? What pressure is it showing? We need more info... ----== Posted via Newsfeeds.Com - Unlimited-Unrestricted-Secure Usenet News==---- http://www.newsfeeds.com The #1 Newsgroup Service in the World! 120,000+ Newsgroups ----= East and West-Coast Server Farms - Total Privacy via Encryption =---- |
#6
Posted to uk.d-i-y
|
|||
|
|||
Loud banging from airing cupboard and crunching sound from radiators
Hello
The boiler is not a Combi, sorry about that, do not know what I was thinking. Thanks in advance Kevin "Kevin Cowans" wrote in message ... Hello Alan What type of boiler has your system got? It it a combi? The boiler is a Maxol HomeWarm 600 (Combi). Is there a hot water cylinder in the airing cupboard? Yes It it a sealed system (with a pressure guage)? What pressure is it showing? No Hope this helps. Kevin "Alan" wrote in message ... "Kevin Cowans" wrote in message ... Hello all I hope someone can help me with this problem as it is starting to really annoy us. I leave the heating turned on at the timer in the airing cupboard and control the heating with the thermostat situated in the hall. After the heating has been on for a few hours (this is not constant) at approximately 20 Degrees C there is a very loud banging that sounds as if it is coming from the airing cupboard. There is also a kind of crunching sound that comes from the radiators even though they are warm. If I run the hot water tap for a few seconds then the banging will stop. I have tried to bleed the radiators using the key but there is little or no air in them. Is there anyway to get rid of air in the system easily without having to get a plumber in? I had thought about draining down the system but do not really know how to do this and also do not know if this would get rid of the air. Thanks in advance for any help you can provide. Kevin What type of boiler has your system got? It it a combi? Is there a hot water cylinder in the airing cupboard? It it a sealed system (with a pressure guage)? What pressure is it showing? We need more info... ----== Posted via Newsfeeds.Com - Unlimited-Unrestricted-Secure Usenet News==---- http://www.newsfeeds.com The #1 Newsgroup Service in the World! 120,000+ Newsgroups ----= East and West-Coast Server Farms - Total Privacy via Encryption =---- |
#7
Posted to uk.d-i-y
|
|||
|
|||
Loud banging from airing cupboard and crunching sound from radiators
Hello
Thanks for the reply. I have checked the expansion tank and as far as I can tell everything is correct, however I am unable to locate a valve in the loft. This problem has me confused, plus everytime we have British Gas come out the noise does not happen which does not make diagnosing the problem any easier. Thanks in advance Kevin "S Viemeister" wrote in message ... Kevin Cowans wrote: After the heating has been on for a few hours (this is not constant) at approximately 20 Degrees C there is a very loud banging that sounds as if it is coming from the airing cupboard. There is also a kind of crunching sound that comes from the radiators even though they are warm. If I run the hot water tap for a few seconds then the banging will stop. I have tried to bleed the radiators using the key but there is little or no air in them. My heating system had symptoms like that - it seems that the plumber we had paid to (among other things) add anti-freeze to the system, had turned off the water to the expansion tank while doing the work, and had neglected to turn it back on when done. The tank was lidless - and about 18 months later, most of the water had evaporated. It was the middle of winter, my young daughter and I were alone, and it sounded like the system was about to explode!. After running the hot tap and turning off the heating, I checked the tank in the loft, saw it was empty, found the valve, which was carefully hidden by insulation, and turned it on. The tank now has a lid, and I called a different plumber the next time I needed work done.... |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
problem in airing cupboard | UK diy | |||
Radiator in airing cupboard | UK diy | |||
Building an airing cupboard | UK diy | |||
air con vent into loft or airing cupboard? | UK diy | |||
Airing cupboard in B/room | UK diy |