Default Re-filling central heating system with 1 rad removed

Is this ok?


  #2   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 3,356
Default Re-filling central heating system with 1 rad removed

On Thu, 1 Nov 2007 12:37:44 -0000 someone who may be "diy-newby"
wrote this:-

Is this ok?


Provided that the valves at both ends of the removed radiator are
turned off and watertight.

Count the number of turns on the regulating valve, so you can open
it to the same position when you replace the radiator.

If the control valve has a thermostatic head make sure it has a
decorator's cap fitted to ensure it stays shut.

When refilling have bowls and towels ready in case either valve is
not fully shut. Central heating valves do sometimes leak as they are
often operated infrequently.



--
David Hansen, Edinburgh
I will *always* explain revoked encryption keys, unless RIP prevents me
http://www.opsi.gov.uk/acts/acts2000/00023--e.htm#54
  #3   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 2,488
Default Re-filling central heating system with 1 rad removed

In an earlier contribution to this discussion,
David Hansen wrote:

On Thu, 1 Nov 2007 12:37:44 -0000 someone who may be "diy-newby"
wrote this:-

Is this ok?


Provided that the valves at both ends of the removed radiator are
turned off and watertight.

Count the number of turns on the regulating valve, so you can open
it to the same position when you replace the radiator.

If the control valve has a thermostatic head make sure it has a
decorator's cap fitted to ensure it stays shut.

When refilling have bowls and towels ready in case either valve is
not fully shut. Central heating valves do sometimes leak as they are
often operated infrequently.


I would also make sure that the pipes to the disconnected radiator are full
of water, to reduce the risk of airlocks upstream which may affect other
rads. You can do this, once you've filled most of the system, by cracking
each valve open with a bowl under it until water rather than air comes out -
then shutting it again.
--
Cheers,
Roger
______
Email address maintained for newsgroup use only, and not regularly
monitored.. Messages sent to it may not be read for several weeks.
PLEASE REPLY TO NEWSGROUP!


Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Removed a radiator. Can I still use the central heating? Dysanovic UK diy 10 November 3rd 06 08:32 PM
Central Heating Bypass on Fully TRV'd SYstem (Incl Honeywell CM37z Zone System) t UK diy 10 April 3rd 06 06:53 PM
air in my central heating system Alan UK diy 4 January 26th 06 02:09 PM
Central heating problem after draining/filling system. JJC001 UK diy 7 July 7th 04 05:08 PM
Filling sealed heating system. Do I need a flexi pipe? Rob UK diy 3 September 3rd 03 09:12 AM


All times are GMT +1. The time now is 01:54 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"