Re-filling central heating system with 1 rad removed
Is this ok?
|
#2
Posted to uk.d-i-y
|
|||
|
|||
Re-filling central heating system with 1 rad removed
On Thu, 1 Nov 2007 12:37:44 -0000 someone who may be "diy-newby"
wrote this:- Is this ok? Provided that the valves at both ends of the removed radiator are turned off and watertight. Count the number of turns on the regulating valve, so you can open it to the same position when you replace the radiator. If the control valve has a thermostatic head make sure it has a decorator's cap fitted to ensure it stays shut. When refilling have bowls and towels ready in case either valve is not fully shut. Central heating valves do sometimes leak as they are often operated infrequently. -- David Hansen, Edinburgh I will *always* explain revoked encryption keys, unless RIP prevents me http://www.opsi.gov.uk/acts/acts2000/00023--e.htm#54 |
#3
Posted to uk.d-i-y
|
|||
|
|||
Re-filling central heating system with 1 rad removed
In an earlier contribution to this discussion,
David Hansen wrote: On Thu, 1 Nov 2007 12:37:44 -0000 someone who may be "diy-newby" wrote this:- Is this ok? Provided that the valves at both ends of the removed radiator are turned off and watertight. Count the number of turns on the regulating valve, so you can open it to the same position when you replace the radiator. If the control valve has a thermostatic head make sure it has a decorator's cap fitted to ensure it stays shut. When refilling have bowls and towels ready in case either valve is not fully shut. Central heating valves do sometimes leak as they are often operated infrequently. I would also make sure that the pipes to the disconnected radiator are full of water, to reduce the risk of airlocks upstream which may affect other rads. You can do this, once you've filled most of the system, by cracking each valve open with a bowl under it until water rather than air comes out - then shutting it again. -- Cheers, Roger ______ Email address maintained for newsgroup use only, and not regularly monitored.. Messages sent to it may not be read for several weeks. PLEASE REPLY TO NEWSGROUP! |