Default Strange Radiator/Boiler problem

Hi all


We have a glow-worm space saver Mk11 Balanced Flue Boiler in the kitchen,
which is used to heat the
water and supply the radiators when heating is required.
Upstairs in the 2nd bedroom there is a cold water tank and hot water tank
with an electric emersion heater.(never used).Also a motorised Mid Position
valve (V4073a).
Today on returning home from work, the hot water has come on via the combi
boiler(no heating on) but the radiators downstairs were all red hot, even
though the timer was set to hot water only and the thermostat in the hallway
was on minimum.

The Boiler setup is a Y PLAN according to this site, if this helps..

http://content.honeywell.com/uk/homes/systems.htm

Any ideas???


  #2   Report Post  
Posted to free.uk.diy.home,uk.d-i-y
external usenet poster
 
Posts: 2,488
Default Strange Radiator/Boiler problem

In an earlier contribution to this discussion,
Tony & Debs wrote:

Hi all


We have a glow-worm space saver Mk11 Balanced Flue Boiler in the
kitchen, which is used to heat the
water and supply the radiators when heating is required.
Upstairs in the 2nd bedroom there is a cold water tank and hot water
tank with an electric emersion heater.(never used).Also a motorised
Mid Position valve (V4073a).
Today on returning home from work, the hot water has come on via the
combi boiler(no heating on) but the radiators downstairs were all red
hot, even though the timer was set to hot water only and the
thermostat in the hallway was on minimum.

The Boiler setup is a Y PLAN according to this site, if this helps..

http://content.honeywell.com/uk/homes/systems.htm

Any ideas???


I don't understand the reference to a 'combi' boiler. Surely, it's a
conventional boiler providing CH and stored HW rather than 'instant' HW,
isn't it?

When did you last consciously use the heating?

The most likely cause of your problem is that the mid-position valve has
stuck, and isn't returning to the HW-only position - but that begs the
question as to why it ever moved away from this position in mid-summer. In
addition, I would have expected the upstairs radiators to be hot at the same
time - unless they're all turned off, or are all fitted with TRVs which have
been turned down.
--
Cheers,
Roger
______
Email address maintained for newsgroup use only, and not regularly
monitored.. Messages sent to it may not be read for several weeks.
PLEASE REPLY TO NEWSGROUP!


  #3   Report Post  
Posted to free.uk.diy.home,uk.d-i-y
external usenet poster
 
Posts: 61
Default Strange Radiator/Boiler problem

On 23 Jun, 21:22, "Tony & Debs" wrote:
Hi all

We have a glow-worm space saver Mk11 Balanced Flue Boiler in the kitchen,
which is used to heat the
water and supply the radiators when heating is required.
Upstairs in the 2nd bedroom there is a cold water tank and hot water tank
with an electric emersion heater.(never used).Also a motorised Mid Position
valve (V4073a).
Today on returning home from work, the hot water has come on via the combi
boiler(no heating on) but the radiators downstairs were all red hot, even
though the timer was set to hot water only and the thermostat in the hallway
was on minimum.

The Boiler setup is a Y PLAN according to this site, if this helps..

http://content.honeywell.com/uk/homes/systems.htm

Any ideas???


Not too sure of how your system is set up. Is the combi connected as
part of the heating circuit with the glow worm or are the two
separate? Sounds like could be a problem with the cross connection
bettween the two.

  #4   Report Post  
Posted to free.uk.diy.home,uk.d-i-y
external usenet poster
 
Posts: 6
Default Strange Radiator/Boiler problem


"Chas" wrote in message
ups.com...
On 23 Jun, 21:22, "Tony & Debs" wrote:
Hi all

We have a glow-worm space saver Mk11 Balanced Flue Boiler in the
kitchen,
which is used to heat the
water and supply the radiators when heating is required.
Upstairs in the 2nd bedroom there is a cold water tank and hot water tank
with an electric emersion heater.(never used).Also a motorised Mid
Position
valve (V4073a).
Today on returning home from work, the hot water has come on via the
combi
boiler(no heating on) but the radiators downstairs were all red hot, even
though the timer was set to hot water only and the thermostat in the
hallway
was on minimum.

The Boiler setup is a Y PLAN according to this site, if this helps..

http://content.honeywell.com/uk/homes/systems.htm

Any ideas???


Not too sure of how your system is set up. Is the combi connected as
part of the heating circuit with the glow worm or are the two
separate? Sounds like could be a problem with the cross connection
bettween the two.



Hi sorry No combi just the standard Glowworm boiler..
HTH

Tony


  #5   Report Post  
Posted to free.uk.diy.home,uk.d-i-y
external usenet poster
 
Posts: 25,191
Default Strange Radiator/Boiler problem

Tony & Debs wrote:

Hi sorry No combi just the standard Glowworm boiler..
HTH


One possibility that fits the symptoms is the mid position valve is
stuck, and you have thermostatic rad valves upstairs but not down.

--
Cheers,

John.

/================================================== ===============\
| Internode Ltd - http://www.internode.co.uk |
|-----------------------------------------------------------------|
| John Rumm - john(at)internode(dot)co(dot)uk |
\================================================= ================/
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Strange Radiator problem/Gravity return valve??? Tony & Debs UK diy 6 June 22nd 07 08:59 AM
Bubbling Boiler/radiator (but only when boiler first comes on) [email protected] UK diy 2 December 27th 06 07:16 PM
Strange noise from radiator Adam-the-Kiwi UK diy 11 October 12th 06 07:41 PM
Strange noise after fitting radiator & draining system preecy UK diy 2 June 8th 05 09:55 AM
radiator / boiler problem - help - im freezing! [email protected] UK diy 11 December 27th 04 05:44 PM


All times are GMT +1. The time now is 12:29 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"