Default electric underfloor heating

wrote:
Hi,

I was hoping to fit UFH. I've looked at Screwfix and also TLC direct.
The latter seems cheaper (taking into account they quote ex vat). The
Screwfix ones come with diy instructions (albeit the electrics must be
connected by a suitable person if in a bathroom: part P etc). However
the TLC ones say strictly not for DIY use. Are they really that
different? From what I can see, installation is the same. You measure
the resistance before and the resistance after. It should be the same.
If it isn't you don't use it and call an expert in.


I looked at the TLC one. The installation manual requires that you
measure the insulation resistance at 500V. I've never seen any others
that ask you to use anything more than 10 quid multimeter. I'd use a
megger anyway, but I've got one; most (95%) DIYers won't. I suspect
that's most of what they mean by 'not for DIY'.

The most noticable thing about the product is that the cable is 4mm.
Everyone else seems to be offering 3mm - 3.5mm. The difference, of
course, is no more than an extra bag of adhesive, if that. Maybe BN are
offering old stock, maybe they've decided that 3mm is too fragile.
Dunno. But FHS (Handyheat by another name) have been around for 4 years
longer than BN (est summer 2005, 'with the simple objective of being the
best choice for commercial and industrial electric heating').



I'm about to buy from Handyheat/FHS. They offer a lifetime guarantee
(versus 10 years for TLC). Still worth sod all, since I doubt it covers
relaying the floor in the event of a problem. They also don't require
the thermostat to be put in conduit. I emailed them to ask why (at 8pm,
and got a reply at 3am!), and they said it's because they have a new
one-piece design made a few years ago, and since then have had zero
sensor failures. The thermostat appears to be exactly the same as the
TLC one, though obviously the thermostat is the least critical part of
the system for reliability. Oh, and they also have telephone support. No
idea what that's like.

I'll be laying a cable kit, with spacing suitable to keep the floor
warm, and using a radiator to heat the room when required. It turns out
that TLC are actually more expensive for that, after adding a stat,
delivery, and vat.

Ben
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Electric Underfloor Heating - AHT Heating [email protected] UK diy 11 March 14th 06 12:50 PM
Electric Underfloor Heating mjb UK diy 3 February 19th 06 04:55 PM
Electric Underfloor Heating the Whole 3 bedroom house. Advice please. [email protected] UK diy 2 February 11th 06 11:19 AM
electric underfloor heating... in2minds UK diy 5 November 1st 04 12:42 PM
Electric underfloor heating Christian McArdle UK diy 9 August 12th 03 01:53 PM


All times are GMT +1. The time now is 04:33 AM.

Powered by vBulletin® Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.
Copyright ©2004-2025 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"