I have a rad in bathroom, 700mm wide, 600 high, 50mm deep. It has 26
water channels running vertically approx 15mm wide and 10mm deep,
spaced at 10mm, It has 40mm fins on the back, and the whole thing is in
a kind of open metal box with slots on the top.
Any idea what BTU this would be ?
I'm looking at replacements like towel radiators etc, but dont want
less heating capacity than I have.
Thanks,
Simon.

  #2   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 22
Default rating this radiator


sm_jamieson wrote:
I have a rad in bathroom, 700mm wide, 600 high, 50mm deep. It has 26
water channels running vertically approx 15mm wide and 10mm deep,
spaced at 10mm, It has 40mm fins on the back, and the whole thing is in
a kind of open metal box with slots on the top.
Any idea what BTU this would be ?
I'm looking at replacements like towel radiators etc, but dont want
less heating capacity than I have.
Thanks,
Simon.


About 2300 BTU if it's a single panel.

  #3   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 759
Default rating this radiator

On 5 Jan 2007 01:13:40 -0800, "sm_jamieson"
wrote:

|I have a rad in bathroom, 700mm wide, 600 high, 50mm deep. It has 26
|water channels running vertically approx 15mm wide and 10mm deep,
|spaced at 10mm, It has 40mm fins on the back, and the whole thing is in
|a kind of open metal box with slots on the top.
|Any idea what BTU this would be ?
|I'm looking at replacements like towel radiators etc, but dont want
|less heating capacity than I have.

Go to the Stelrad web site http://www.stelrad.com/ or any other
manufacturer of radiators. Find something similar and use the BTW/watts
figure of that.
--
Dave Fawthrop dave hyphenologist co uk Google Groups is IME the *worst*
method of accessing usenet. GG subscribers would be well advised get a
newsreader, say Agent, and a newsserver, say news.individual.net. These
will allow them: to see only *new* posts, a killfile, and other goodies.
  #4   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 2,688
Default rating this radiator


avocado wrote:

sm_jamieson wrote:
I have a rad in bathroom, 700mm wide, 600 high, 50mm deep. It has 26
water channels running vertically approx 15mm wide and 10mm deep,
spaced at 10mm, It has 40mm fins on the back, and the whole thing is in
a kind of open metal box with slots on the top.
Any idea what BTU this would be ?
I'm looking at replacements like towel radiators etc, but dont want
less heating capacity than I have.
Thanks,
Simon.


About 2300 BTU if it's a single panel.

Yep, single panel with fins.
Cheers,
Simon.

  #5   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 2,488
Default rating this radiator

In an earlier contribution to this discussion,
sm_jamieson wrote:

I have a rad in bathroom, 700mm wide, 600 high, 50mm deep. It has 26
water channels running vertically approx 15mm wide and 10mm deep,
spaced at 10mm, It has 40mm fins on the back, and the whole thing is
in a kind of open metal box with slots on the top.
Any idea what BTU this would be ?
I'm looking at replacements like towel radiators etc, but dont want
less heating capacity than I have.
Thanks,
Simon.


As others have said, find a similarly sized single finned radiator in a
maker's catalogue, and note the heating capacity.

But be aware that a towel radiator of the same physical size will provide
but a fraction of this rad's heating output - about 1/3 if you're lucky - so
you'll need a *massive* towel rad to get the current output level.

When comparing radiator specs in catalogues, make sure that they all use the
same delta-T - 'cos they might not - and adjust the figures as necessary.
--
Cheers,
Roger
______
Email address maintained for newsgroup use only, and not regularly
monitored.. Messages sent to it may not be read for several weeks.
PLEASE REPLY TO NEWSGROUP!




  #6   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 3,356
Default rating this radiator

On 5 Jan 2007 01:13:40 -0800 someone who may be "sm_jamieson"
wrote this:-

I have a rad in bathroom, [sniip]
I'm looking at replacements like towel radiators etc


Why?

Why not simply add a towel rail to dry towels and leave the radiator
to warm the room? The towel rail may add a little heat, but not much
unless it is a model with built in radiator.


--
David Hansen, Edinburgh
I will *always* explain revoked encryption keys, unless RIP prevents me
http://www.opsi.gov.uk/acts/acts2000/00023--e.htm#54
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Snapped the radiator tap off the radiator (Now it's boiling & can't swtich it off) [email protected] UK diy 20 April 18th 06 09:37 PM
Using a standard radiator as an electric towel radiator [email protected] UK diy 5 October 11th 05 11:41 AM
Carpet Rating IC_Clearly Home Repair 5 March 9th 05 06:43 PM
1/2 drywall fire rating and fire rating attic ladder mrdenial Home Ownership 1 February 1st 05 05:30 PM
Radiator valve to radiator tail coupling Lee Wright UK diy 1 August 22nd 03 10:11 AM


All times are GMT +1. The time now is 04:44 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"