Default Gas boiler keeps constantly relighting

Hi, I have a Saunier Duval Xeon 50ff boiler, about 5 years old, never
been properly serviced but I clean it out myself. It has just started
taking a few seconds to light, having to spark a number of times.
However, weird thing is that it keeps redoing the ignition sequence
about every 30 seconds, it remains lit and works, but you get the
irritating noise of it constantly relighting. Now, the spark electrode
is worn down so that the gap between it and the burner is at least
double what it's supposed to be i.e. 7-8mm instead of 2-4mm. Don't
know whether it requires a simple replacement of the electrode?
What do you think might be the problem? Thanks.

  #2   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 2,231
Default Gas boiler keeps constantly relighting

On Fri, 22 Dec 2006 07:16:36 -0800, russell_nash wrote:

Hi, I have a Saunier Duval Xeon 50ff boiler, about 5 years old, never
been properly serviced but I clean it out myself. It has just started
taking a few seconds to light, having to spark a number of times.
However, weird thing is that it keeps redoing the ignition sequence
about every 30 seconds, it remains lit and works, but you get the
irritating noise of it constantly relighting. Now, the spark electrode
is worn down so that the gap between it and the burner is at least
double what it's supposed to be i.e. 7-8mm instead of 2-4mm. Don't
know whether it requires a simple replacement of the electrode?
What do you think might be the problem? Thanks.


It is possible that the spark electrode is also the flame sense electrode,
so get that put right first. You have some sort of flame sensor failure
which is more likely to be its lead or electrode than anything else.

--
Ed Sirett - Property maintainer and registered gas fitter.
The FAQ for uk.diy is at http://www.diyfaq.org.uk
Gas fitting FAQ http://www.makewrite.demon.co.uk/GasFitting.html
Sealed CH FAQ http://www.makewrite.demon.co.uk/SealedCH.html
Choosing a Boiler FAQ http://www.makewrite.demon.co.uk/BoilerChoice.html
Gas Fitting Standards Docs he http://www.makewrite.demon.co.uk/GasFittingStandards
  #3   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 3
Default Gas boiler keeps constantly relighting

Thanks a lot Ed, I will follow your advice and try to get a new
electrode, which will be easy to fit and bit cheaper than a circuit
board. :-)


Ed Sirett wrote:

On Fri, 22 Dec 2006 07:16:36 -0800, russell_nash wrote:

Hi, I have a Saunier Duval Xeon 50ff boiler, about 5 years old, never
been properly serviced but I clean it out myself. It has just started
taking a few seconds to light, having to spark a number of times.
However, weird thing is that it keeps redoing the ignition sequence
about every 30 seconds, it remains lit and works, but you get the
irritating noise of it constantly relighting. Now, the spark electrode
is worn down so that the gap between it and the burner is at least
double what it's supposed to be i.e. 7-8mm instead of 2-4mm. Don't
know whether it requires a simple replacement of the electrode?
What do you think might be the problem? Thanks.


It is possible that the spark electrode is also the flame sense electrode,
so get that put right first. You have some sort of flame sensor failure
which is more likely to be its lead or electrode than anything else.

--
Ed Sirett - Property maintainer and registered gas fitter.
The FAQ for uk.diy is at http://www.diyfaq.org.uk
Gas fitting FAQ http://www.makewrite.demon.co.uk/GasFitting.html
Sealed CH FAQ http://www.makewrite.demon.co.uk/SealedCH.html
Choosing a Boiler FAQ http://www.makewrite.demon.co.uk/BoilerChoice.html
Gas Fitting Standards Docs he http://www.makewrite.demon.co.uk/GasFittingStandards


  #4   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 3
Default Gas boiler keeps constantly relighting

Ok, I replaced the electrode, everything seems fine now. Thanks.


russell_nash wrote:

Thanks a lot Ed, I will follow your advice and try to get a new
electrode, which will be easy to fit and bit cheaper than a circuit
board. :-)


Ed Sirett wrote:

On Fri, 22 Dec 2006 07:16:36 -0800, russell_nash wrote:

Hi, I have a Saunier Duval Xeon 50ff boiler, about 5 years old, never
been properly serviced but I clean it out myself. It has just started
taking a few seconds to light, having to spark a number of times.
However, weird thing is that it keeps redoing the ignition sequence
about every 30 seconds, it remains lit and works, but you get the
irritating noise of it constantly relighting. Now, the spark electrode
is worn down so that the gap between it and the burner is at least
double what it's supposed to be i.e. 7-8mm instead of 2-4mm. Don't
know whether it requires a simple replacement of the electrode?
What do you think might be the problem? Thanks.


It is possible that the spark electrode is also the flame sense electrode,
so get that put right first. You have some sort of flame sensor failure
which is more likely to be its lead or electrode than anything else.

--
Ed Sirett - Property maintainer and registered gas fitter.
The FAQ for uk.diy is at http://www.diyfaq.org.uk
Gas fitting FAQ http://www.makewrite.demon.co.uk/GasFitting.html
Sealed CH FAQ http://www.makewrite.demon.co.uk/SealedCH.html
Choosing a Boiler FAQ http://www.makewrite.demon.co.uk/BoilerChoice.html
Gas Fitting Standards Docs he http://www.makewrite.demon.co.uk/GasFittingStandards


Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Trianco Boiler Cutting Out Constantly technics100 UK diy 17 November 3rd 15 11:29 PM
compaq xn5000 hdd works constantly and fan spins constantly pocco Electronics Repair 0 November 26th 06 07:32 PM
Combi boiler burning constantly! Al Deveron UK diy 11 August 9th 06 11:43 AM
Gas Stove top constantly clicks Libba Home Repair 3 September 17th 05 08:22 PM
boiler fires on and off constantly - Biasi Riva Jon UK diy 4 July 18th 04 11:17 AM


All times are GMT +1. The time now is 02:52 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"