Hi All

In our new kitchen they've fitted six of the 50w mains halogen
downlighters.
All very pretty - but a right pain to 'see by', unless you happen to
be standing directly under one of the spots ('beam us up, Scotty!')
So - an expensive (300 watt) way to generate light & dark patches g

So - thinking about fitting some 'hidden' fluorescent lighting on top
of the wall-units, so as to bounce light off the walls / ceiling, and
get a better, more diffused, lighting setup.

Only one of the wall units is long enough to 'hide' a 4ft tube - the
others are shorter - between 2' and 3'6"....

So - from a quick search on the web it seems that the common options
in tubular fluorescent are 2ft and 4ft..... which suggests using one
or more of the shorter tubes on top of the shorter cabinets...

Alternatively, what about using a number of compact fluorescents on
top of each cabinet ...? - anybody tried this ? how did it look ? -
was the illumination 'even'

Finally, given a choice, what's the most 'acceptable' colour for the
tubes - as in white, warm white, etc ?

Advice / suggestions please ?

TIA
Adrian
  #2   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 9,560
Default Fluorescent lighting in new kitchen.....

Adrian wrote:

Hi All

In our new kitchen they've fitted six of the 50w mains halogen
downlighters.
All very pretty - but a right pain to 'see by', unless you happen to
be standing directly under one of the spots ('beam us up, Scotty!')
So - an expensive (300 watt) way to generate light & dark patches g

So - thinking about fitting some 'hidden' fluorescent lighting on top
of the wall-units, so as to bounce light off the walls / ceiling, and
get a better, more diffused, lighting setup.

Only one of the wall units is long enough to 'hide' a 4ft tube - the
others are shorter - between 2' and 3'6"....

So - from a quick search on the web it seems that the common options
in tubular fluorescent are 2ft and 4ft..... which suggests using one
or more of the shorter tubes on top of the shorter cabinets...

Alternatively, what about using a number of compact fluorescents on
top of each cabinet ...? - anybody tried this ? how did it look ? -
was the illumination 'even'

Finally, given a choice, what's the most 'acceptable' colour for the
tubes - as in white, warm white, etc ?

Advice / suggestions please ?

TIA
Adrian


There are a couple of sections on here that address your qs
specifically.
http://wiki.diyfaq.org.uk/index.php?title=Rewiring_Tips
I'd stick with 2' tubes rather than 4'.


NT

  #3   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 673
Default Fluorescent lighting in new kitchen.....

Hi

On 20 Dec 2006 10:45:35 -0800, wrote:

Adrian wrote:

Hi All

In our new kitchen they've fitted six of the 50w mains halogen
downlighters.
All very pretty - but a right pain to 'see by', unless you happen to
be standing directly under one of the spots ('beam us up, Scotty!')
So - an expensive (300 watt) way to generate light & dark patches g

So - thinking about fitting some 'hidden' fluorescent lighting on top
of the wall-units, so as to bounce light off the walls / ceiling, and
get a better, more diffused, lighting setup.

Only one of the wall units is long enough to 'hide' a 4ft tube - the
others are shorter - between 2' and 3'6"....

So - from a quick search on the web it seems that the common options
in tubular fluorescent are 2ft and 4ft..... which suggests using one
or more of the shorter tubes on top of the shorter cabinets...

Alternatively, what about using a number of compact fluorescents on
top of each cabinet ...? - anybody tried this ? how did it look ? -
was the illumination 'even'

Finally, given a choice, what's the most 'acceptable' colour for the
tubes - as in white, warm white, etc ?

Advice / suggestions please ?

TIA
Adrian


There are a couple of sections on here that address your qs
specifically.
http://wiki.diyfaq.org.uk/index.php?title=Rewiring_Tips
I'd stick with 2' tubes rather than 4'.

Thanks for the link.
OK - now I know more (than I ever wanted to know ! g) about tubes
and colour temperatures...

So - go for 2ft tubes then.....

I've never done this 'lighs on top of the wall units' thing before -
presumably the best way to determine 'how many' tubes is to actually
try it & see ?
Probably looks better if all wall-units have illumination above them
....?

Thanks
Adrian
  #4   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 1,226
Default Fluorescent lighting in new kitchen.....

On Thu, 21 Dec 2006 10:44:52 +0000, Adrian wrote:

Hi

On 20 Dec 2006 10:45:35 -0800, wrote:

Adrian wrote:

Hi All

In our new kitchen they've fitted six of the 50w mains halogen
downlighters.
All very pretty - but a right pain to 'see by', unless you happen to be
standing directly under one of the spots ('beam us up, Scotty!') So -
an expensive (300 watt) way to generate light & dark patches g

So - thinking about fitting some 'hidden' fluorescent lighting on top
of the wall-units, so as to bounce light off the walls / ceiling, and
get a better, more diffused, lighting setup.

Only one of the wall units is long enough to 'hide' a 4ft tube - the
others are shorter - between 2' and 3'6"....

So - from a quick search on the web it seems that the common options in
tubular fluorescent are 2ft and 4ft..... which suggests using one or
more of the shorter tubes on top of the shorter cabinets...

Alternatively, what about using a number of compact fluorescents on top
of each cabinet ...? - anybody tried this ? how did it look ? - was the
illumination 'even'

Finally, given a choice, what's the most 'acceptable' colour for the
tubes - as in white, warm white, etc ?

Advice / suggestions please ?

TIA
Adrian


There are a couple of sections on here that address your qs specifically.
http://wiki.diyfaq.org.uk/index.php?title=Rewiring_Tips I'd stick with 2'
tubes rather than 4'.

Thanks for the link.
OK - now I know more (than I ever wanted to know ! g) about tubes and
colour temperatures...

So - go for 2ft tubes then.....

I've never done this 'lighs on top of the wall units' thing before -
presumably the best way to determine 'how many' tubes is to actually try
it & see ?
Probably looks better if all wall-units have illumination above them ...?

Thanks
Adrian


===============================
Homebase had some 3' fittings yesterday so they might be worth looking at.

Cic.

--
================================
Testing UBUNTU Linux
Everything working so far
================================

  #5   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 673
Default Fluorescent lighting in new kitchen.....

Hi Cicero

On Thu, 21 Dec 2006 12:12:15 GMT, Cicero
wrote:
big snip

So - go for 2ft tubes then.....

I've never done this 'lighs on top of the wall units' thing before -
presumably the best way to determine 'how many' tubes is to actually try
it & see ?
Probably looks better if all wall-units have illumination above them ...?

Thanks
Adrian


===============================
Homebase had some 3' fittings yesterday so they might be worth looking at.

Cic.


Thanks for the suggestion. Never heard of 3ft fittings before - you
live & learn g

I'd be a bit wary of finding that, having bought them, you couldn't
get replacement tubes easily.....

Being 'out in the sticks' here in S-W Ireland, it's a 2 hour drive to
the nearest Homebase - so I'll try the specialist lighting shop in the
next town. Who knows - they might even be clued up on different
'colours' of tubes !

Many thanks
Adrian


  #6   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 11,175
Default Fluorescent lighting in new kitchen.....

In article ,
Adrian writes:
Hi All

In our new kitchen they've fitted six of the 50w mains halogen
downlighters.
All very pretty - but a right pain to 'see by', unless you happen to
be standing directly under one of the spots ('beam us up, Scotty!')
So - an expensive (300 watt) way to generate light & dark patches g

So - thinking about fitting some 'hidden' fluorescent lighting on top
of the wall-units, so as to bounce light off the walls / ceiling, and
get a better, more diffused, lighting setup.

Only one of the wall units is long enough to 'hide' a 4ft tube - the
others are shorter - between 2' and 3'6"....

So - from a quick search on the web it seems that the common options
in tubular fluorescent are 2ft and 4ft..... which suggests using one
or more of the shorter tubes on top of the shorter cabinets...


You could look at using the T4 under cupboard lights on top of
the cupboards (although they aren't that powerful).

Also, there are two relatively new ranges of T5 fluorescent tubes
available now, T5HE (High Efficiency) and T5HO (High Output).
These are available in various long lengths which are not the
same as the older tubes in 1ft multiples, and you might find
a better match for cupboard length. They can only be run from
electronic control gear, and they are similar efficiency to T8's (on
electronic control gear). Being T5, they are lower profile on top of
the cupboards, which may be an advantage. You will have to get tubes
from wholesalers at the moment, as they haven't made inroads into
the domestic market. Check that the colour temperature you want is
available before committing too. Ballasts, endcaps, etc can also be
found mail-order (they use same end-caps as old T5 tubes).

On a single narrow cupboard, I have used a 2-D fluorescent tube,
and recessed this in to the top (in this case, because you would
otherwise see it when stepping down into the kitchen from the
higher dining room).

Alternatively, what about using a number of compact fluorescents on
top of each cabinet ...? - anybody tried this ? how did it look ? -
was the illumination 'even'


I suspect the height of them might be an issue if you want them
to remain hidden.

Finally, given a choice, what's the most 'acceptable' colour for the
tubes - as in white, warm white, etc ?


If you intend to light a kitchen brightly for practical food
preparation use, use 3500K. If you don't want it so bright
(to create more of a warm mood) and/or you will mix with any
filament lamps, use 2700K.

The colour names you quote are not used very consistently, but
2700K is often referred to as warm white, and 3500K as white.
However, a white from different manufacturers could vary from
something like 3400K to 4000K, so don't assume all whites will
be the same (and similarly for the other colour names).

--
Andrew Gabriel
  #7   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 9,560
Default Fluorescent lighting in new kitchen.....

Adrian wrote:

Hi Cicero

On Thu, 21 Dec 2006 12:12:15 GMT, Cicero
wrote:
big snip

So - go for 2ft tubes then.....

I've never done this 'lighs on top of the wall units' thing before -
presumably the best way to determine 'how many' tubes is to actually try
it & see ?
Probably looks better if all wall-units have illumination above them ...?

Thanks
Adrian


===============================
Homebase had some 3' fittings yesterday so they might be worth looking at.

Cic.


Thanks for the suggestion. Never heard of 3ft fittings before - you
live & learn g

I'd be a bit wary of finding that, having bought them, you couldn't
get replacement tubes easily.....

Being 'out in the sticks' here in S-W Ireland, it's a 2 hour drive to
the nearest Homebase - so I'll try the specialist lighting shop in the
next town. Who knows - they might even be clued up on different
'colours' of tubes !

Many thanks
Adrian


I wouldnt use 3' ers.

If you want to try it out, why not get some 50p lamp holders on flexes,
put cfls in them and bung them up there. Adjust till happy.


NT

  #8   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 673
Default Fluorescent lighting in new kitchen.....

Hi NT

On 21 Dec 2006 10:26:26 -0800, wrote:

Adrian wrote:

Hi Cicero

On Thu, 21 Dec 2006 12:12:15 GMT, Cicero
wrote:
big snip

So - go for 2ft tubes then.....

I've never done this 'lighs on top of the wall units' thing before -
presumably the best way to determine 'how many' tubes is to actually try
it & see ?
Probably looks better if all wall-units have illumination above them ...?

Thanks
Adrian

===============================
Homebase had some 3' fittings yesterday so they might be worth looking at.

Cic.


Thanks for the suggestion. Never heard of 3ft fittings before - you
live & learn g

I'd be a bit wary of finding that, having bought them, you couldn't
get replacement tubes easily.....

Being 'out in the sticks' here in S-W Ireland, it's a 2 hour drive to
the nearest Homebase - so I'll try the specialist lighting shop in the
next town. Who knows - they might even be clued up on different
'colours' of tubes !

Many thanks
Adrian


I wouldnt use 3' ers.

If you want to try it out, why not get some 50p lamp holders on flexes,
put cfls in them and bung them up there. Adjust till happy.


Might just do that g
Tried the local lighting shop - they had lots of little
'mini-fluorescent tubes' for mounting under the wall-cabinets - but
nothing in the way of larger units for bouncing light from the top of
cabinets.

CFLs might be the way to go - I have a couple of high-intensity units
that I use for photography - that's somewhere to start.....

Thanks
Adrian
NT

  #9   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 9,560
Default Fluorescent lighting in new kitchen.....

Adrian wrote:
Hi NT


If you want to try it out, why not get some 50p lamp holders on flexes,
put cfls in them and bung them up there. Adjust till happy.


Might just do that g
Tried the local lighting shop - they had lots of little
'mini-fluorescent tubes' for mounting under the wall-cabinets - but
nothing in the way of larger units for bouncing light from the top of
cabinets.

CFLs might be the way to go - I have a couple of high-intensity units
that I use for photography - that's somewhere to start.....

Thanks
Adrian


Once you've got it looking as you want, if you get there, you can
replce them with permament linear fl fittings. Linear fl gives much
longer lamp life, higher efficacy and more even light spread.


NT

Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Fluorescent lighting Mark Spice UK diy 4 February 8th 06 09:33 AM
Fluorescent lighting Rumble UK diy 0 February 7th 06 05:19 PM
Fluorescent lighting Mike Harrison UK diy 0 February 7th 06 04:29 PM
Fluorescent lighting Sponix UK diy 0 February 7th 06 03:27 PM
fluorescent lighting stuart noble UK diy 17 October 15th 04 10:25 PM


All times are GMT +1. The time now is 05:52 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"