Hi,

I'm replacing all the doors in my 3rd floor flat and am wondering if
anyone knows the rules regarding fire doors? I would prefer not to put
fire doors in a couple of rooms as they are so expensive so am I
legally able to fit normal doors?

Darren.

  #2   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 2,379
Default Fire doors

The rules are complicated:

http://www.planningportal.gov.uk/eng...000000084.html

  #4   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 8
Default Fire doors


It depends on whether your floors are concrete or your flat is in an
old converted house with wooden floors. Obviously there is much greater
risk if the latter.
Fire doors shouldnt be so expensive because basically they are just a
wooden door with a half inch plasterslab built inside it. If its a
modern concrete flat a fireproof door on the front would be enough.


The flat is purpose built in 1990 with wooden floors.

  #6   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 2,379
Default Fire doors


The flat is purpose built in 1990 with wooden floors.


If it was purpose built so recently, there's likely to be good reason
for every fire door. Kitchens and lounges need them as the likely seat
of the fire, bedrooms as they're likely to be the room where you're
trapped.

It could be that the only possible escape route from your flat is via
the main entrance, so no matter where a fire breaks out in your flat,
you are relying on the door to that room to hold back the fire so you
can get to the one and only exit. Remember fire doors have intumescent
seals to hold back smoke as well.

Or the other scenario - you open the door to whatever room you (or your
family/guests) are in to find the fire has already cut off your escape
route and you are then dependent on the door to the room you are in to
hold back the fire.

You would also be shooting yourself in the foot when you sell the flat
one day - and the buyers surveyor points out the problem
(non-compliance with a regulatory requirement), and the buyers mortgage
company won't touch it.

Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Chantecler Windows and Doors Brian White Home Repair 3 June 6th 16 11:22 PM
Interior doors in-between 'featherweight' and 'fire door' quality? jkn UK diy 8 August 6th 05 01:43 AM
mdf wardrobe doors gary watson UK diy 10 October 27th 04 04:04 PM
Internal fire doors / slamming ! & Shower problems Nick UK diy 8 January 28th 04 03:50 PM


All times are GMT +1. The time now is 02:02 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"