Hi,

The programmer that controls my central heating and hot water fails to communicate with the boiler and the boiler is continually 'ON'

The programmer is set at 'OFF' but the boiler still fires

The RET Electronic Room Thermostat that controls the central heating also fails to switch the boiler off even when turned fully down.

Because of this my central heating is continually 'on' and the thermostat fails to switch do anything in controlling the room temp as the boiler fails to switch off.

It has been suggested that I have a faulty motorised valve which is stuck in the 'on' position.

I assume that the motorised valve operating the central heating may be faulty.

There seems to be 2 motorised valves beside my water tank:-

1 - Synchron HPA2 Actuator/HPV26 valve(plastic box/white cover)
2 - Synchron 272848 Honeywell Motorised valve(metal box)

But which valve of the two is faulty?

1 is situated just above and in line with the pump and feeds into the top of the cylinder tank

2 is situated off of the main pump and and then travels down to the ground floor.

I guess that 2 is the one that controls the central heating?

All the wires that serve both valves go into a junction box so it is easy to isolate each valve but which one?

Will changing just the actuator resolve the problem because having had both actuators off each valve appears to turn except that 2 valve is what I could say a little stiff and jerky.

Will I have to drain the system?

There appears to be alot of 'stop taps' above and below each valve which sould facilitate removing of the valve.

I am tempted to just change the actuator!!

What does anyone think?

please advise

Cheers

Diezel
 
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
switching motorised valves Fatboise UK diy 5 November 16th 05 11:36 PM
motorised valves Hugh UK diy 4 February 10th 05 11:04 AM
Motorised valves - good makes? logized UK diy 25 July 27th 04 07:50 AM
Can you get 15mm 2-port motorised valves? Set Square UK diy 18 February 26th 04 02:33 PM
Motorised valves: suppliers? Grunff UK diy 9 July 8th 03 11:11 PM


All times are GMT +1. The time now is 11:58 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"