  #1   Report Post  
Posted to uk.d-i-y,free.uk.diy.home
external usenet poster
 
Posts: 9
Default Tee fitting within close proximity to outlet from combi boiler

Is it wise to connect a tee almost immediately after the boiler hot
water outlet?

The boiler pipework would go back about 6"from the boiler into an equal
tee; one side of which would go downwards to an adjacent shower room,
the other upwards before branching to the main bathroom and kitchen.

I am very grateful for any comments

  #2   Report Post  
Posted to uk.d-i-y,free.uk.diy.home
external usenet poster
 
Posts: 4,046
Default Tee fitting within close proximity to outlet from combi boiler


"Matt" wrote in message
ps.com...

Is it wise to connect a tee almost
immediately after the boiler hot
water outlet?

The boiler pipework would go
back about 6"from the boiler into an equal
tee; one side of which would go downwards
to an adjacent shower room,
the other upwards before branching to the
main bathroom and kitchen.

I am very grateful for any comments


No probs. Best tee off at the same point for the hot supply for all showers.
Also tee off just before the cold inlet the cold supplies to the showers
too. Also at the maintap have a dedicated pipe to the cold inlet to the
combi. At the maintap tee off and run all non-shower taps off this. It
reduces influence of other taps on the shower's operation. In a domestic
house the shower is king and it must take priority over all others.

  #3   Report Post  
Posted to uk.d-i-y,free.uk.diy.home
external usenet poster
 
Posts: 369
Default Tee fitting within close proximity to outlet from combi boiler


"Doctor Drivel" wrote in message
reenews.net...

Best tee off at the same point for the hot supply for all showers.
Also tee off just before the cold inlet the cold supplies to the showers
too. Also at the maintap have a dedicated pipe to the cold inlet to the
combi. At the maintap tee off and run all non-shower taps off this. It
reduces influence of other taps on the shower's operation. In a domestic
house the shower is king and it must take priority over all others.


I have a handy outdoor tap feed (Teed off main tap) next to the boiler (the
only water on this side of the house). Are you saying that it would be
better to take an independendent feed from mains-in ?

Mike W


  #4   Report Post  
Posted to uk.d-i-y,free.uk.diy.home
external usenet poster
 
Posts: 3,703
Default Tee fitting within close proximity to outlet from combi boiler

In article om,
Matt writes
Is it wise to connect a tee almost immediately after the boiler hot
water outlet?

The boiler pipework would go back about 6"from the boiler into an equal
tee; one side of which would go downwards to an adjacent shower room,
the other upwards before branching to the main bathroom and kitchen.

I'm assuming this is the domestic hot water output that you're talking
about. If so then the limited flow available from a combi is unlikely to be
restricted by the T. If it was the central heating circuit however I'd find a
way to avoid it.
--
fred
Plusnet - I hope you like vanilla
  #5   Report Post  
Posted to uk.d-i-y,free.uk.diy.home
external usenet poster
 
Posts: 4,046
Default Tee fitting within close proximity to outlet from combi boiler


"VisionSet" wrote in message
...

"Doctor Drivel" wrote in message
reenews.net...

Best tee off at the same point for the hot supply for all showers.
Also tee off just before the cold inlet the cold supplies to the showers
too. Also at the maintap have a dedicated pipe to the cold inlet to the
combi. At the maintap tee off and run all non-shower taps off this. It
reduces influence of other taps on the shower's operation. In a domestic
house the shower is king and it must take priority over all others.


I have a handy outdoor tap feed (Teed off main tap) next to the boiler
(the
only water on this side of the house). Are you saying that it would be
better to take an independendent feed from mains-in ?


Yep. The cowboys pipe up combis with one 15mm mains pipe snaking around the
house, tee all cold taps off this and also the combi. The combi is then
regarded as just another tap. Then peopel wnmonder why copmbis don't work
too well. It needs a dedicated cold supply directly from the maintap. Have
the maintap a full-bore type too.




  #6   Report Post  
Posted to uk.d-i-y,free.uk.diy.home
external usenet poster
 
Posts: 4,046
Default Tee fitting within close proximity to outlet from combi boiler


"fred" wrote in message ...
In article om,
Matt writes
Is it wise to connect a tee almost immediately after the boiler hot
water outlet?

The boiler pipework would go back about 6"from the boiler into an equal
tee; one side of which would go downwards to an adjacent shower room,
the other upwards before branching to the main bathroom and kitchen.

I'm assuming this is the domestic hot water output that you're talking
about. If so then the limited flow available from a combi is unlikely to
be
restricted by the T.


It may be a highflow combi.

  #7   Report Post  
Posted to uk.d-i-y,free.uk.diy.home
external usenet poster
 
Posts: 9
Default Tee fitting within close proximity to outlet from combi boiler

Yeah, it's domestic hot - the heating pipes just go straight up.

I have fitted the same "handy garden tap feed" and washing machine
sharing the boiler cold feed - do i need to rethink this?

Vaillant have specified 15mm cold-in & domestic hot-out pipe
connections to the boileir (it's an ecoTEC Plus 831).

fred wrote:
In article om,
Matt writes
Is it wise to connect a tee almost immediately after the boiler hot
water outlet?

The boiler pipework would go back about 6"from the boiler into an equal
tee; one side of which would go downwards to an adjacent shower room,
the other upwards before branching to the main bathroom and kitchen.

I'm assuming this is the domestic hot water output that you're talking
about. If so then the limited flow available from a combi is unlikely to be
restricted by the T. If it was the central heating circuit however I'd find a
way to avoid it.
--
fred
Plusnet - I hope you like vanilla


Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Glow-Worm Combi Boiler Fault Paul S UK diy 2 December 11th 05 04:12 AM
Help - I have a back boiler and want a combi boiler fitted but have plastic pipes! Vikki Home Repair 1 November 22nd 05 11:51 PM
Price of fitting combi boiler dog-man UK diy 15 March 24th 05 10:12 PM
Clunking in combi boiler when tap is closed: due to back pressure? dave L UK diy 0 May 9th 04 10:50 AM
New Combi boiler GB UK diy 7 September 7th 03 11:34 PM


All times are GMT +1. The time now is 01:49 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"