I have a Vaillant TCW sine T3W combi-boiler and the pressure has fallen below 1. How do i refill the system to get the pressure back between 1 and 3?
  #2   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 14
Default Vaillant TCW sine T3W

I don't know this particular boiler, but most combis have a filling loop
(braided flexible hose) from the mains water feed that connects with a lumpy
nut to a threaded filling valve - attach this, and open the taps at both
ends of the filling loop, the gauge pressure should start climbing, once
it's where you want it, close the valves and remove the filling loop at one
end, catching the drops in your hat.

Hope this helps,
Dave H.
(The engineer formerly known as Homeless)
"danw29" wrote in message
...

I have a Vaillant TCW sine T3W combi-boiler and the pressure has fallen
below 1. How do i refill the system to get the pressure back between 1
and 3?




--
danw29



  #3   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 2,231
Default Vaillant TCW sine T3W

On Fri, 07 Jul 2006 20:49:57 +0100, danw29 wrote:


I have a Vaillant TCW sine T3W combi-boiler and the pressure has fallen
below 1. How do i refill the system to get the pressure back between 1
and 3?


This boiler (around 20 years + ) uses an external filling loop.
See the sealed system FAQ. for details.
I wouldn't worry about the pressure if it's only just under 1.



--
Ed Sirett - Property maintainer and registered gas fitter.
The FAQ for uk.diy is at http://www.diyfaq.org.uk
Gas fitting FAQ http://www.makewrite.demon.co.uk/GasFitting.html
Sealed CH FAQ http://www.makewrite.demon.co.uk/SealedCH.html
Choosing a Boiler FAQ http://www.makewrite.demon.co.uk/BoilerChoice.html
Gas Fitting Standards Docs he http://www.makewrite.demon.co.uk/GasFittingStandards

  #4   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 2,466
Default Vaillant TCW sine T3W

In message , Dave H.
writes
I don't know this particular boiler, but most combis have a filling loop
(braided flexible hose) from the mains water feed that connects with a lumpy
nut to a threaded filling valve - attach this, and open the taps at both
ends of the filling loop, the gauge pressure should start climbing, once
it's where you want it, close the valves and remove the filling loop at one
end, catching the drops in your hat.

Apart from what the top poster said

You need to find where the water's going

--
geoff
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Vaillant Boiler/CH Issue hasanzehn UK diy 0 December 1st 04 05:22 PM
Vaillant Boiler help David Herman UK diy 0 November 27th 04 03:15 PM
WARNING TO VAILLANT ECOMAX 6 & 8 SERIES BOILER OWNERS Carl UK diy 5 January 12th 04 01:50 PM
plumes from Vaillant 622/2E System boiler Peter UK diy 5 November 21st 03 05:49 PM
Vaillant VCW Sine 18 Combi boiler Jay and mike 1 UK diy 2 October 7th 03 09:10 AM


All times are GMT +1. The time now is 11:49 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"