Vaillant TCW sine T3W
I have a Vaillant TCW sine T3W combi-boiler and the pressure has fallen below 1. How do i refill the system to get the pressure back between 1 and 3?
|
#2
Posted to uk.d-i-y
|
|||
|
|||
Vaillant TCW sine T3W
I don't know this particular boiler, but most combis have a filling loop
(braided flexible hose) from the mains water feed that connects with a lumpy nut to a threaded filling valve - attach this, and open the taps at both ends of the filling loop, the gauge pressure should start climbing, once it's where you want it, close the valves and remove the filling loop at one end, catching the drops in your hat. Hope this helps, Dave H. (The engineer formerly known as Homeless) "danw29" wrote in message ... I have a Vaillant TCW sine T3W combi-boiler and the pressure has fallen below 1. How do i refill the system to get the pressure back between 1 and 3? -- danw29 |
#3
Posted to uk.d-i-y
|
|||
|
|||
Vaillant TCW sine T3W
On Fri, 07 Jul 2006 20:49:57 +0100, danw29 wrote:
I have a Vaillant TCW sine T3W combi-boiler and the pressure has fallen below 1. How do i refill the system to get the pressure back between 1 and 3? This boiler (around 20 years + ) uses an external filling loop. See the sealed system FAQ. for details. I wouldn't worry about the pressure if it's only just under 1. -- Ed Sirett - Property maintainer and registered gas fitter. The FAQ for uk.diy is at http://www.diyfaq.org.uk Gas fitting FAQ http://www.makewrite.demon.co.uk/GasFitting.html Sealed CH FAQ http://www.makewrite.demon.co.uk/SealedCH.html Choosing a Boiler FAQ http://www.makewrite.demon.co.uk/BoilerChoice.html Gas Fitting Standards Docs he http://www.makewrite.demon.co.uk/GasFittingStandards |
#4
Posted to uk.d-i-y
|
|||
|
|||
Vaillant TCW sine T3W
In message , Dave H.
writes I don't know this particular boiler, but most combis have a filling loop (braided flexible hose) from the mains water feed that connects with a lumpy nut to a threaded filling valve - attach this, and open the taps at both ends of the filling loop, the gauge pressure should start climbing, once it's where you want it, close the valves and remove the filling loop at one end, catching the drops in your hat. Apart from what the top poster said You need to find where the water's going -- geoff |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Vaillant Boiler/CH Issue | UK diy | |||
Vaillant Boiler help | UK diy | |||
WARNING TO VAILLANT ECOMAX 6 & 8 SERIES BOILER OWNERS | UK diy | |||
plumes from Vaillant 622/2E System boiler | UK diy | |||
Vaillant VCW Sine 18 Combi boiler | UK diy |